Thermal noise in a high Q ultracryogenic resonator -: art. no. 074501

被引:10
作者
Vinante, A [1 ]
Mezzena, R
Prodi, GA
Vitale, S
Cerdonio, M
Bonaldi, M
Falferi, P
机构
[1] Univ Trent, Dipartimento Fis, I-38050 Trento, Italy
[2] Ist Nazl Fis Nucl, Grp Coll Trento, Sez Padova, I-38050 Trento, Italy
[3] Univ Padua, Dipartimento Fis, I-35131 Padua, Italy
[4] Ist Nazl Fis Nucl, Sez Padova, I-35131 Padua, Italy
[5] CNR, ITC, Ist Foton & Nanotecnol, I-38050 Trento, Italy
关键词
D O I
10.1063/1.1947927
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A high Q electrical resonator based on a superconducting coil and a low loss capacitor has been realized and characterized at temperatures down to 60 mK. The resonance frequency is near 10 kHz, and the quality factor is higher than 10(5). The main purpose of the experiment is to test the feasibility of cooling to ultracryogenic temperatures the readout of the gravitational wave detector AURIGA, which is based on a high Q resonant electrical matching network. The resonator current noise, measured by a superconducting quantum interference device amplifier, scales with temperature in the full range 60 mK-4.2 K, showing that the system is thermal noise limited and its dissipating elements are well thermalized. Some implications of these results and possible applications are discussed. (c) 2005 American Institute of Physics.
引用
收藏
页数:5
相关论文
共 20 条
[1]   NOISE MEASUREMENTS ON SILICON J-FETS AT LOW-TEMPERATURE USING A VERY HIGH Q-SUPERCONDUCTING RESONATOR [J].
AYELA, F ;
BRET, JL ;
CHAUSSY, J .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1991, 62 (11) :2816-2821
[2]   DESIGN AND APPLICATIONS OF A VERY LOW LOSSES SUPERCONDUCTING LC RESONATOR AT 4.2-K [J].
AYELA, F ;
BRET, JL ;
CHAUSSY, J .
CRYOGENICS, 1992, 32 (01) :35-38
[3]  
BAGGIO L, IN PRESS PHYS REV LE
[4]  
BIGNOTO M, IN PRESS REV SCI INS
[5]   Thermal noise in a high Q cryogenic resonator [J].
Bonaldi, M ;
Falferi, P ;
Cerdonio, M ;
Vinante, A ;
Dolesi, R ;
Vitale, S .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (03) :1851-1856
[6]  
Braginsky VB, 1985, SYSTEMS SMALL DISSIP
[7]   Noise sources and dissipation mechanisms of a 120 h SQUID amplifier [J].
Falferi, P ;
Bonaldi, M ;
Cavalleri, A ;
Cerdonio, M ;
Vinante, A ;
Mezzena, R ;
Xu, KX ;
Prodi, GA ;
Vitale, S .
APPLIED PHYSICS LETTERS, 2003, 82 (06) :931-933
[8]   A HIGH INDUCTANCE KHZ RESONATOR WITH A QUALITY FACTOR LARGER THAN 10(6) [J].
FALFERI, P ;
CERDONIO, M ;
FRANCESCHINI, L ;
MACCHIETTO, R ;
VITALE, S ;
ZENDRI, JP .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1994, 65 (09) :2916-2919
[9]   Measurement of the dynamic input impedance of a dc superconducting quantum interference device at audio frequencies [J].
Falferi, P ;
Mezzena, R ;
Vitale, S ;
Cerdonio, M .
APPLIED PHYSICS LETTERS, 1997, 71 (07) :956-958
[10]   ULTIMATE SENSITIVITY LIMIT OF A RESONANT GRAVITATIONAL WAVE ANTENNA USING A LINEAR MOTION DETECTOR [J].
GIFFARD, RP .
PHYSICAL REVIEW D, 1976, 14 (10) :2478-2486