摘要
The fusion engineering research experiment (FIRE) device is designed for high power density and advanced physics operating modes. Due to the short distance of the divertor from the X-point, the connection lengths are short and the scrape off layer thickness is small. A relatively high peak heat flux of 25 MW/m(2) is expected on the divertor. The FIRE divertor engineering design is based on the design approaches developed for international thermonuclear experimental reactor (ITER). The geometry of the FIRE divertor consists of water cooled copper fingers and a tungsten brush armor as plasma facing material. The divertor assembly consists of modular units for remote handling. A 316 stainless steel back plate is used for support and manifolding. The backing plate is joined to the copper fingers by pins. The coolant channel diameter is 8 mm at a pitch of 14 mm. The total power flow to the outer divertor is 35 MW. Water at an inlet temperature of 30 degreesC, 1.5 MPa and a flow velocity of 10 m/s is used with two channels in series. A margin of approximate to 1.6 is obtained on the critical heat flux. A three dimensional thermal stress finite element (FE) analysis of this geometry was performed. Thermal hydraulic correlations derived for ITER were used to perform the thermal analysis. Design changes were implemented to reduce the stresses and temperatures to acceptable levels. (C) 2003 Published by Elsevier Science B.V.
引用
收藏
页码:323 / 327
页数:5
相关论文
共 50 条
  • [1] Thermal hydraulic analysis of FIRE divertor
    Baxi, CB
    Ulrickson, MA
    Driemeyer, DE
    Heitzenroeder, P
    FUSION TECHNOLOGY, 2001, 39 (02): : 408 - 411
  • [2] Conceptual design of coolant circuits and thermal stress analysis for JA-DEMO divertor
    Asakura, Nobuyuki
    Kakudate, Satoshi
    Chen, Weixi
    Utoh, Hiroyasu
    Someya, Youji
    Sakamoto, Yoshiteru
    FUSION ENGINEERING AND DESIGN, 2024, 206
  • [3] Thermal analysis of protruding surfaces in the JET divertor
    Corre, Y.
    Bunting, P.
    Coenen, J. W.
    Gaspar, J.
    Iglesias, D.
    Matthews, G. F.
    Balboa, I.
    Coffey, I.
    Dejarnac, R.
    Firdaouss, M.
    Gauthier, E.
    Jachmich, S.
    Krieger, K.
    Pitts, R. A.
    Rack, M.
    Silburn, S. A.
    Abduallev, S.
    Abhangi, M.
    Abreu, P.
    Afzal, M.
    Aggarwal, K. M.
    Ahlgren, T.
    Ahn, J. H.
    Aho-Mantila, L.
    Aiba, N.
    Airila, M.
    Albanese, R.
    Aldred, V.
    Alegre, D.
    Alessi, E.
    Aleynikov, P.
    Alfier, A.
    Alkseev, A.
    Allinson, M.
    Alper, B.
    Alves, E.
    Ambrosino, G.
    Ambrosino, R.
    Amicucci, L.
    Amosov, V.
    Sunden, E. Andersson
    Angelone, M.
    Anghel, M.
    Angioni, C.
    Appel, L.
    Appelbee, C.
    Arena, P.
    Ariola, M.
    Arnichand, H.
    Arshad, S.
    NUCLEAR FUSION, 2017, 57 (06)
  • [4] 3D stress analysis of ITER divertor cassette under thermal and electromagnetic loads
    Berchov, NF
    Bykov, VA
    Komarov, VM
    Korolkov, MD
    Mazul, IV
    PLASMA DEVICES AND OPERATIONS, 1998, 6 (1-3): : 65 - 72
  • [5] Thermal/stress analysis of a failed fire-tube heater treater
    Zangeneh, Sh.
    Bakhtiari, R.
    Veysi, F.
    Jowzi, M.
    ENGINEERING FAILURE ANALYSIS, 2020, 116
  • [7] THERMAL ANALYSIS TO CALCULATE THE VESSEL TEMPERATURE AND STRESS IN ALCATOR C-MOD DUE TO THE DIVERTOR UPGRADE
    Zhang, Han
    Titus, Peter H.
    Ellis, Robert
    Harrison, Soren
    Vieira, Rui
    FUSION SCIENCE AND TECHNOLOGY, 2013, 64 (02) : 250 - 254
  • [8] Thermal and irradiation induced stress analysis on relevant target plate structure of the divertor for fusion experimental reactors
    Ishiyama, S
    Akiba, M
    Eto, M
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2000, 37 (01) : 90 - 101
  • [9] Thermal analysis of the vertical target for the ITER divertor design
    Grigoriev, S.
    Mazul, I.
    Tanchuk, V.
    Gornikel, I.
    Tivey, R.
    22ND IEEE/NPSS SYMPOSIUM ON FUSION ENGINEERING, 2007, : 82 - +
  • [10] Thermal analysis of an exposed tungsten edge in the JET divertor
    Arnoux, G.
    Loenen, J.
    Bazylev, B.
    Corre, Y.
    Matthews, G. F.
    Balboa, I.
    Clever, M.
    Dejarnac, R.
    Devaux, S.
    Eich, T.
    Gauthier, E.
    Frassinetti, L.
    Horacek, J.
    Jachmich, S.
    Kinna, D.
    Marsen, S.
    Mertens, Ph.
    Pitts, R. A.
    Rack, M.
    Sergienko, G.
    Sieglin, B.
    Stamp, M.
    Thompson, V.
    JOURNAL OF NUCLEAR MATERIALS, 2015, 463 : 415 - 419