Systematic Derivation of Safety Limits for Time-Varying 5G Radiofrequency Exposure Based on Analytical Models and Thermal Dose

被引:32
作者
Neufeld, Esra [1 ]
Kuster, Niels [1 ,2 ]
机构
[1] Fdn Res Informat Technol Soc ITIS, Zeughausstr 43, CH-8004 Zurich, Switzerland
[2] Swiss Fed Inst Technol, CH-8092 Zurich, Switzerland
来源
HEALTH PHYSICS | 2018年 / 115卷 / 06期
关键词
dosimetry; electromagnetic fields; exposure; radiofrequency; FREQUENCY-RANGE; TEMPERATURE;
D O I
10.1097/HP.0000000000000930
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Extreme broadband wireless devices operating above 10 GHz may transmit data in bursts of a few milliseconds to seconds. Even though the time- and area-averaged power density values remain within the acceptable safety limits for continuous exposure, these bursts may lead to short temperature spikes in the skin of exposed people. In this paper, a novel analytical approach to pulsed heating is developed and applied to assess the peak-to-average temperature ratio as a function of the pulse fraction (relative to the averaging time T; it corresponds to the inverse of the peak-to-average ratio). This has been analyzed for two different perfusion-related thermal time constants ((1) = 100 s and 500 s) corresponding to plane-wave and localized exposures. To allow for peak temperatures that considerably exceed the 1 K increase, the CEM43 tissue damage model, with an experimental-data-based damage threshold for human skin of 600 min, is used to allow large temperature oscillations that remain below the level at which tissue damage occurs. To stay consistent with the current safety guidelines, safety factors of 10 for occupational exposure and 50 for the general public were applied. The model assumptions and limitations (e.g., employed thermal and tissue damage models, homogeneous skin, consideration of localized exposure by a modified time constant) are discussed in detail. The results demonstrate that the maximum averaging time, based on the assumption of a thermal time constant of 100 s, is 240 s if the maximum local temperature increase for continuous-wave exposure is limited to 1 K and 0.1. For a very low peak-to-average ratio of 100 ( 0.01), it decreases to only 30 s. The results also show that the peak-to-average ratio of 1,000 tolerated by the International Council on Non-Ionizing Radiation Protection guidelines may lead to permanent tissue damage after even short exposures, highlighting the importance of revisiting existing exposure guidelines.
引用
收藏
页码:705 / 711
页数:7
相关论文
共 16 条
  • [1] Ahlbom A, 1998, HEALTH PHYS, V74, P494
  • [2] RECENT DEVELOPMENTS IN MODELING HEAT-TRANSFER IN BLOOD-PERFUSED TISSUES
    ARKIN, H
    XU, LX
    HOLMES, KR
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1994, 41 (02) : 97 - 107
  • [3] Conventional and newly developed bioheat transport models in vascularized tissues: A review
    Bhowmik, Arka
    Singh, Rupesh
    Repaka, Ramjee
    Mishra, Subhash C.
    [J]. JOURNAL OF THERMAL BIOLOGY, 2013, 38 (03) : 107 - 125
  • [4] Carrasco E, 2018, REVISION REV PHYS ME
  • [5] Christ A., 2018, RAD PROT DOS
  • [6] THERMAL REGULATION DURING ACCLIMATIZATION IN A HOT, DRY (DESERT TYPE) ENVIRONMENT
    EICHNA, LW
    PARK, CR
    NELSON, N
    HORVATH, SM
    PALMES, ED
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY, 1950, 163 (03): : 585 - 597
  • [7] THERMAL RESPONSE OF HUMAN SKIN TO MICROWAVE ENERGY: A CRITICAL REVIEW
    Foster, Kenneth R.
    Ziskin, Marvin C.
    Balzano, Quirino
    [J]. HEALTH PHYSICS, 2016, 111 (06): : 528 - 541
  • [8] Influence of body temperature on the development of fatigue during prolonged exercise in the heat
    González-Alonso, J
    Teller, C
    Andersen, SL
    Jensen, FB
    Hyldig, T
    Nielsen, B
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1999, 86 (03) : 1032 - 1039
  • [9] IEEE International Committee on Electromagnetic Safety (SCC39), 2006, SAF LEV RESP HUM EXP, DOI [10. 1109/IEEESTD. 2006. 99501, DOI 10.1109/IEEESTD.2006.99501]
  • [10] IEEE International Committee on Electromagnetic Safety (SCC39), 2010, IEEE STAND SAF LEV R, DOI [10. 1109/IEEESTD. 2010. 5433227, DOI 10.1109/IEEESTD.2010.5433227]