Ophthalmic artery Doppler at 19-23 weeks' gestation in pregnancies that deliver small-for-gestational-age neonates

被引:3
作者
Azim, S. Abdel [1 ,2 ]
Wright, A. [3 ]
Sapantzoglou, I [1 ]
Nicolaides, K. H. [1 ]
Charakida, M. [1 ,4 ]
机构
[1] Kings Coll Hosp London, Harris Birthright Res Ctr Fetal Med, London, England
[2] Med Univ Innsbruck, Dept Obstet & Gynecol, Innsbruck, Austria
[3] Univ Exeter, Inst Hlth Res, Exeter, Devon, England
[4] Kings Coll London, Sch Biomed Engn & Imaging Sci, London, England
关键词
Doppler; ophthalmic artery; SGA; small-for-gestational age; GROWTH RESTRICTION; PREECLAMPSIA; PREDICTION; PRESSURE; HISTORY; DISEASE; WOMEN; RISK;
D O I
10.1002/uog.24913
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives First, to explore hemodynamic differences between pregnancies delivering a small-for-gestational-age (SGA) neonate in the absence of hypertensive disorders and those that develop pre-eclampsia (PE) or gestational hypertension (GH), by comparing the ophthalmic artery peak systolic velocity (PSV) ratio and first (PSV1) and second (PSV2) PSV at 19-23 weeks' gestation, and second, to compare these pregnancies for markers of placental perfusion and function. Methods This was a prospective observational study in women attending for a routine hospital visit at 19 + 1 to 23 + 3 weeks' gestation. This visit included recording of maternal demographic characteristics and medical history, ultrasound examination for assessment of fetal anatomy and growth, and measurement of maternal ophthalmic artery PSV ratio, PSV1, PSV2, mean arterial pressure (MAP), uterine artery pulsatility index (UtA-PI) and serum placental growth factor (PlGF). The values of PSV ratio, PSV1, PSV2, MAP, UtA-PI and PlGF were converted to multiples of the median (MoM) or deltas. Mean MoMs or deltas of these biomarkers in the SGA, PE and GH groups were compared with those in the unaffected group. The definition of SGA was birth weight below the 10(th) percentile in the absence of PE or GH. Results The study population of 5214 pregnancies contained 4375 (83.9%) that were unaffected by SGA, PE or GH, 563 (10.8%) complicated by SGA, 157 (3.0%) with PE and 119 (2.3%) with GH. There were three main findings of the study. First, in the SGA, PE and GH groups, compared with unaffected pregnancies, the PSV ratio delta, PSV2 MoM, MAP MoM and UtA-PI MoM were increased and PlGF MoM was decreased; however, the magnitude of most changes was smaller in the SGA group than in PE and GH groups. Second, in the PE and GH groups, but not in the SGA group, PSV1 MoM was increased. Third, in general, in the pathological pregnancies, the magnitude of deviation of biomarkers from unaffected pregnancies was greater for those delivering at < 37 than at >= 37 weeks' gestation. Conclusion In mid-gestation, pregnancies that subsequently develop hypertensive disorders and those delivering a SGA neonate, compared with unaffected pregnancies, have abnormal uteroplacental measurements and increased maternal ophthalmic artery PSV ratio. These data suggest similar pathophysiology in the two conditions, with evidence of placental dysfunction and increased peripheral vascular resistance, but the magnitude of abnormalities is greater in hypertensive disorders. (c) 2022 International Society of Ultrasound in Obstetrics and Gynecology.
引用
收藏
页码:52 / 58
页数:7
相关论文
共 50 条
  • [31] Estimated weight centile as a predictor of perinatal outcome in small-for-gestational-age pregnancies with normal fetal and maternal Doppler indices
    Savchev, S.
    Figueras, F.
    Cruz-Martinez, R.
    Illa, M.
    Botet, F.
    Gratacos, E.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2012, 39 (03) : 299 - 303
  • [32] First-trimester screening for early and late small-for-gestational-age neonates using maternal serum biochemistry, blood pressure and uterine artery Doppler
    Crovetto, F.
    Crispi, F.
    Scazzocchio, E.
    Mercade, I.
    Meler, E.
    Figueras, F.
    Gratacos, E.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2014, 43 (01) : 34 - 40
  • [33] Measurement of spiral artery jets: general principles and differences observed in small-for-gestational-age pregnancies
    Collins, S. L.
    Birks, J. S.
    Stevenson, G. N.
    Papageorghiou, A. T.
    Noble, J. A.
    Impey, L.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2012, 40 (02) : 171 - 178
  • [34] Maternal serum placental growth hormone at 11-13 weeks' gestation in pregnancies delivering small for gestational age neonates
    Sifakis, Stavros
    Akolekar, Ranjit
    Kappou, Dimitra
    Mantas, Nikitas
    Nicolaides, Kypros H.
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2012, 25 (09) : 1796 - 1799
  • [35] REDUCED PLACENTAL VILLOUS TREE ELABORATION IN SMALL-FOR-GESTATIONAL-AGE PREGNANCIES - RELATIONSHIP WITH UMBILICAL ARTERY DOPPLER WAVE-FORMS
    JACKSON, MR
    WALSH, AJ
    MORROW, RJ
    MULLEN, JBM
    LYE, SJ
    RITCHIE, JW
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1995, 172 (02) : 518 - 525
  • [36] Outcome of small-for-gestational-age fetuses according to umbilical artery Doppler: Is there any yield from additional middle cerebral artery Doppler?
    Nanthakomon, Tongta
    Uerpairojkit, Boonchai
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2010, 23 (08) : 900 - 905
  • [37] Maternal Serum Vitamin D at 11-13 Weeks in Pregnancies Delivering Small for Gestational Age Neonates
    Ertl, Rebecca
    Yu, Christina K. H.
    Samaha, Robert
    Akolekar, Ranjit
    Nicolaides, Kypros H.
    FETAL DIAGNOSIS AND THERAPY, 2012, 31 (02) : 103 - 108
  • [38] Association of Doppler parameters with placental signs of underperfusion in late-onset small-for-gestational-age pregnancies
    Parra-Saavedra, M.
    Crovetto, F.
    Triunfo, S.
    Savchev, S.
    Peguero, A.
    Nadal, A.
    Gratacos, E.
    Figueras, F.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2014, 44 (03) : 330 - 337
  • [39] Maternal serum activin A, inhibin A, and follistatin in pregnancies with appropriately grown and small-for-gestational-age fetuses classified by umbilical artery Doppler ultrasound
    Bobrow, CS
    Holmes, RP
    Muttukrishna, S
    Mohan, A
    Groome, N
    Murphy, DJ
    Soothill, PW
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2002, 186 (02) : 283 - 287
  • [40] Predicting small for gestational age in the first trimester of pregnancy using maternal ophthalmic artery Doppler indices
    Gurgel Alves, Julio Augusto
    Maia e Holanda Moura, Sammya Bezerra
    Araujo Junior, Edward
    Tonni, Gabriele
    Martins, Wellington P.
    Costa, Fabricio Da Silva
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2016, 29 (07) : 1190 - 1194