High-performance liquid chromatographic assay of asymmetric dimethylarginine, symmetric dimethylarginine, and arginine in human plasma by derivatization with naphthalene-2,3-dicarboxaldehyde

被引:57
作者
Marra, M
Bonfigli, AR
Testa, R
Testa, I
Gambini, A
Coppa, G
机构
[1] INRCA, Dept Gerontol Res, Diabetol Unit, I-60131 Ancona, Italy
[2] Gen Hosp, Dept Clin Pathol, Ancona, Italy
[3] Univ Aquila, Inst Internal Med, I-67100 Laquila, Italy
关键词
asymmetric dimethylarginine; symmetric dimethylarginine; arginine; high-performance liquid chromatography; naphthalene-2,3-dicarboxaldehyde;
D O I
10.1016/S0003-2697(03)00157-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Asymmetric dimethylarginine (ADMA) is an emerging cardiovascular risk factor. Its increased levels have been hypothesized to be a cause of endothelial dysfunction in pathological conditions such as hypertension, dyslipidemia, renal failure, hyperglycemia, and hyperhomocysteinemia. It acts as a potent competitive inhibitor of nitric oxide synthase. Methods using ortho-phthaldialdehyde (OPA) as derivatization reagent are widely performed in HPLC determination of ADMA, but they produce derivatives whose fluorescence rapidly decreases during time. Moreover, these methods do not allow a clear separation of ADMA from its stereoisomer symmetric dimethylarginine (SDMA). Our work describes a new method to determine ADMA, SDMA, and arginine that uses, as derivatizing reagent, naphthalene-2,3-dicarboxaldehyde (NDA). Chromatograms with low background, showing a complete separation of ADMA and SDMA, are obtained: NDA derivatives are considerably more stable than the OPA derivatives. The calibration curves of ADMA and SDMA are linear within the range of 0.01-16.0 muM. Coefficients of variation are less than 1.7% for within day and less then 2.3% for day to day. Absolute mean recoveries from supplemented samples are between 100 and 104%. These characteristics make this method reliable and easily manageable for large routine analyses. (C) 2003 Elsevier Science (USA). All rights reserved.
引用
收藏
页码:13 / 17
页数:5
相关论文
共 42 条
[31]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF RIBONUCLEOTIDES BY POSTCOLUMN DERIVATIZATION INVOLVING OXIDATION FOLLOWED BY FLUORESCENCE REACTION, AND ITS APPLICATION TO HUMAN ERYTHROCYTE SAMPLE [J].
UMEGAE, Y ;
NOHTA, H ;
OHKURA, Y .
ANALYTICAL SCIENCES, 1990, 6 (04) :519-522
[32]   TRACE ANALYSIS OF METHOTREXATE AND 7-HYDROXYMETHOTREXATE IN HUMAN PLASMA AND URINE BY A NOVEL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD [J].
BECK, O ;
SEIDEMAN, P ;
WENNBERG, M ;
PETERSON, C .
THERAPEUTIC DRUG MONITORING, 1991, 13 (06) :528-532
[33]   Adaptation of solid phase extraction to an automated column switching method for online sample cleanup as the basis of a facile and sensitive high-performance liquid chromatographic assay for paclitaxel in human plasma [J].
Supko, JG ;
Nair, RV ;
Seiden, MV ;
Lu, H .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 21 (05) :1025-1036
[34]   Determination of nateglinide in human plasma by high-performance liquid chromatography with pre-column derivatization using a coumarin-type fluorescent reagent [J].
Malli, Danai ;
Gikas, Evagelos ;
Vavagiannis, Andreas ;
Kazanis, Michael ;
Daniilides, Konstantinos ;
Gennimata, Dimitra ;
Panderi, Irene .
ANALYTICA CHIMICA ACTA, 2007, 599 (01) :143-150
[35]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF ACIDIC CATECHOLAMINE METABOLITES IN HUMAN URINE USING POSTCOLUMN FLUORESCENCE DERIVATIZATION WITH DL-1,2-DIPHENYLETHYLENEDIAMINE [J].
JEON, HK ;
NOHTA, H ;
OHKURA, Y .
ANALYTICAL SCIENCES, 1990, 6 (05) :677-682
[36]   High-performance Liquid Chromatographic Ultraviolet Detection of Nilotinib in Human Plasma from Patients with Chronic Myelogenous Leukemia, and Comparison with Liquid ChromatographyTandem Mass Spectrometry [J].
Nakahara, Ryosuke ;
Satho, Yuhki ;
Itoh, Hiroki .
JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2016, 30 (06) :1028-1030
[37]   PRECOLUMN DEPROTEINIZATION METHOD OF HUMAN PLASMA USING A HYDROXYAPATITE CARTRIDGE FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC AMINO-ACID-ANALYSIS [J].
IWASE, H ;
ONO, I .
ANALYTICAL SCIENCES, 1995, 11 (01) :73-77
[38]   Development of a high-performance liquid chromatographic method for the determination of mifepristone in human plasma using norethisterone as an internal standard: application to pharmacokinetic study [J].
Guo, Zhiyong ;
Wang, Sui ;
Wei, Danyi ;
Zha, Jinxia .
CONTRACEPTION, 2007, 76 (03) :228-232
[39]   Analytic validation of the enzyme multiplied immunoassay technique for the determination of mycophenolic acid in plasma from renal transplant recipients compared with a high-performance liquid chromatographic assay [J].
Hosotsubo, H ;
Takahara, S ;
Imamura, R ;
Kyakuno, M ;
Tanaka, T ;
Yazawa, K ;
Hanafusa, T ;
Matsumiya, K ;
Nonomura, N ;
Okuyama, A ;
Sugimoto, H .
THERAPEUTIC DRUG MONITORING, 2001, 23 (06) :669-674
[40]   A HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE MEASUREMENT OF THE IRON CHELATOR 1,2-DIMETHYL-3-HYDROXYPYRIDIN-4-ONE IN HUMAN PLASMA [J].
KLEIN, J ;
DAMANI, LA ;
CHUNG, D ;
EPEMOULU, O ;
OLIVIERI, N ;
KOREN, G .
THERAPEUTIC DRUG MONITORING, 1991, 13 (01) :51-54