Mitral Annulus Segmentation From 3D Ultrasound Using Graph Cuts

被引:55
|
作者
Schneider, Robert J. [1 ]
Perrin, Douglas P. [2 ]
Vasilyev, Nikolay V. [2 ]
Marx, Gerald R. [3 ]
del Nido, Pedro J. [2 ]
Howe, Robert D. [1 ,4 ]
机构
[1] Harvard Univ, Sch Engn & Appl Sci, Cambridge, MA 02138 USA
[2] Childrens Hosp, Dept Cardiac Surg, Boston, MA 02115 USA
[3] Childrens Hosp, Dept Cardiol, Boston, MA 02115 USA
[4] Harvard Mit Div Hlth Sci & Technol, Cambridge, MA 02138 USA
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
Annulus; graph cuts; mitral valve; segmentation; ultrasound; 3-DIMENSIONAL RECONSTRUCTION; FINITE-ELEMENT; VALVE; REGURGITATION; GEOMETRY; SHAPE; CARDIOMYOPATHY; CURVATURE;
D O I
10.1109/TMI.2010.2050595
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The shape of the mitral valve annulus is used in diagnostic and modeling applications, yet methods to accurately and reproducibly delineate the annulus are limited. This paper presents a mitral annulus segmentation algorithm designed for closed mitral valves which locates the annulus in three-dimensional ultrasound using only a single user-specified point near the center of the valve. The algorithm first constructs a surface at the location of the thin leaflets, and then locates the annulus by finding where the thin leaflet tissue meets the thicker heart wall. The algorithm iterates until convergence metrics are satisfied, resulting in an operator-independent mitral annulus segmentation. The accuracy of the algorithm was assessed from both a diagnostic and surgical standpoint by comparing the algorithm's results to delineations made by a group of experts on clinical ultrasound images of the mitral valve, and to delineations made by an expert with a surgical view of the mitral annulus on excised porcine hearts using an electromagnetically tracked pointer. In the former study, the algorithm was statistically indistinguishable from the best performing expert (p = 0.85) and had an average RMS difference of 1.81 +/- 0.78 mm to the expert average. In the latter, the average RMS difference between the algorithm's annulus and the electromagnetically tracked points across six hearts was 1.19 +/- 0.17 mm.
引用
收藏
页码:1676 / 1687
页数:12
相关论文
共 50 条
  • [1] SEGMENTATION OF TERAHERTZ IMAGES USING 3D GRAPH-CUTS
    Dehiya, Vasundhara
    Trocan, Maria
    Amiel, Frederic
    2014 INTERNATIONAL WORKSHOP ON COMPUTATIONAL INTELLIGENCE FOR MULTIMEDIA UNDERSTANDING (IWCIM), 2014,
  • [2] Segmentation of Wood Fibres in 3D CT Images Using Graph Cuts
    Wernersson, Erik L. G.
    Brun, Anders
    Hendriks, Cris L. Luengo
    IMAGE ANALYSIS AND PROCESSING - ICIAP 2009, PROCEEDINGS, 2009, 5716 : 92 - 102
  • [3] Moving object segmentation using dynamic 3D graph cuts and GMM
    Li, Bo
    Yuan, Baozong
    Sun, Yunda
    2006 8TH INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING, VOLS 1-4, 2006, : 1559 - +
  • [4] 3D liver segmentation using multiple region appearances and graph cuts
    Peng, Jialin
    Hu, Peijun
    Lu, Fang
    Peng, Zhiyi
    Kong, Dexing
    Zhang, Hongbo
    MEDICAL PHYSICS, 2015, 42 (12) : 6840 - 6852
  • [5] 3D VERTEBRAE SEGMENTATION USING GRAPH CUTS WITH SHAPE PRIOR CONSTRAINTS
    Aslan, Melih S.
    Ali, Asem
    Chen, Dongqing
    Arnold, Ben
    Farag, Aly A.
    Xiang, Ping
    2010 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, 2010, : 2193 - 2196
  • [6] Better foreground segmentation for 3D face reconstruction using graph cuts
    Park, Anjin
    Hong, Kwangjin
    Jung, Keechul
    ADVANCES IN IMAGE AND VIDEO TECHNOLOGY, PROCEEDINGS, 2007, 4872 : 715 - 726
  • [7] Carotid Artery Lumen Segmentation in 3D Free-Hand Ultrasound Images Using Surface Graph Cuts
    Lorza, Andres M. Arias
    Carvalho, Diego D. B.
    Petersen, Jens
    van Dijk, Anouk C.
    van der Lugt, Aad
    Niessen, Wiro J.
    Klein, Stefan
    de Bruijne, Marleen
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2013, PT II, 2013, 8150 : 542 - 549
  • [8] A Novel 3D Segmentation of Vertebral Bones from Volumetric CT Images Using Graph Cuts
    Aslan, Melih S.
    Ali, Asem
    Rara, Ham
    Arnold, Ben
    Farag, Aly A.
    Fahmi, Rachid
    Xiang, Ping
    ADVANCES IN VISUAL COMPUTING, PT 2, PROCEEDINGS, 2009, 5876 : 519 - +
  • [9] AUTOMATIC SEGMENTATION OF THE LEFT-VENTRICULAR CAVITY AND ATRIUM IN 3D ULTRASOUND USING GRAPH CUTS AND THE RADIAL SYMMETRY TRANSFORM
    Juang, Radford
    McVeigh, Elliot R.
    Hoffmann, Beatrice
    Yuh, David
    Burlina, Philippe
    2011 8TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2011, : 606 - 609
  • [10] Automatic 3D object segmentation in multiple views using volumetric graph-cuts
    Campbell, N. D. F.
    Vogiatzis, G.
    Hernandez, C.
    Cipolla, R.
    IMAGE AND VISION COMPUTING, 2010, 28 (01) : 14 - 25