Accelerated and Navigator-Gated Look-Locker Imaging for Cardiac T1 Estimation (ANGIE): Development and Application to T1 Mapping of the Right Ventricle

被引:52
作者
Mehta, Bhairav B. [1 ]
Chen, Xiao [1 ]
Bilchick, Kenneth C. [3 ]
Salerno, Michael [1 ,2 ,3 ]
Epstein, Frederick H. [1 ,2 ]
机构
[1] Univ Virginia, Dept Biomed Engn, Charlottesville, VA 22903 USA
[2] Univ Virginia, Dept Radiol & Med Imaging, Charlottesville, VA 22903 USA
[3] Univ Virginia, Dept Cardiol, Charlottesville, VA 22903 USA
关键词
T1; mapping; MOLLI; right ventricle; compressed sensing; cardiac MRI; navigator gating; DIFFUSE MYOCARDIAL FIBROSIS; MAGNETIC-RESONANCE; INVERSION-RECOVERY; HUMAN BLOOD; T-1; ENHANCEMENT; MRI; RECONSTRUCTION; TIME;
D O I
10.1002/mrm.25100
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo develop a method for high-resolution cardiac T1 mapping. MethodsA new method, accelerated and navigator-gated look-locker imaging for cardiac T1 estimation (ANGIE), was developed. An adaptive acquisition algorithm that accounts for the interplay between navigator gating and undersampling patterns well-suited for compressed sensing was used to minimize scan time. Computer simulations, phantom experiments, and imaging of the left ventricle (LV) were used to optimize and evaluate ANGIE. ANGIE's high spatial resolution was demonstrated by T1 mapping of the right ventricle (RV). Comparisons were made to modified Look-Locker imaging (MOLLI). ResultsRetrospective reconstruction of fully sampled datasets demonstrated the advantages of the adaptive algorithm. For the LV, ANGIE measurements of T1 were in good agreement with MOLLI. For the RV, ANGIE achieved a spatial resolution of 1.2 x 1.2 mm(2) with a scan time of 15753 s per slice, and measured RV T1 values of 980 +/- 96 ms versus 1076 +/- 157 ms for lower-resolution MOLLI. ANGIE provided lower intrascan variation in the RV T1 estimate compared with MOLLI (P<0.05). ConclusionANGIE enables high-resolution cardiac T1 mapping in clinically reasonable scan times. ANGIE opens the prospect of quantitative T1 mapping of thin cardiovascular structures such as the RV wall. Magn Reson Med 73:150-160, 2015. (c) 2014 Wiley Periodicals, Inc.
引用
收藏
页码:150 / 160
页数:11
相关论文
共 49 条
[1]  
Barral J., 2009, Proceedings of the 17th Annual Meeting of ISMRM, P4593
[2]  
Barth M, 1997, CELL MOL BIOL, V43, P783
[3]   Robust uncertainty principles:: Exact signal reconstruction from highly incomplete frequency information [J].
Candès, EJ ;
Romberg, J ;
Tao, T .
IEEE TRANSACTIONS ON INFORMATION THEORY, 2006, 52 (02) :489-509
[4]  
Chow K, 2012, P 20 ANN M ISMRM MEL, P395
[5]   The apparent inversion time for optimal delayed enhancement magnetic resonance imaging differs between the right and left ventricles [J].
Desai, MY ;
Gupta, S ;
Bomma, C ;
Tandri, H ;
Foo, TK ;
Lima, JAC ;
Bluemke, DA .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2005, 7 (02) :475-479
[6]   Compressed sensing [J].
Donoho, DL .
IEEE TRANSACTIONS ON INFORMATION THEORY, 2006, 52 (04) :1289-1306
[7]   Optimally sparse representation in general (nonorthogonal) dictionaries via l1 minimization [J].
Donoho, DL ;
Elad, M .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2003, 100 (05) :2197-2202
[8]   Arrhythmia Insensitive Rapid Cardiac T1 Mapping Pulse Sequence [J].
Fitts, Michelle ;
Breton, Elodie ;
Kholmovski, Eugene G. ;
Dosdall, Derek J. ;
Vijayakumar, Sathya ;
Hong, Kyung P. ;
Ranjan, Ravi ;
Marrouche, Nassir F. ;
Axel, Leon ;
Kim, Daniel .
MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (05) :1274-1282
[9]   Measurement of the gadopentetate dimeglumine partition coefficient in human myocardium in vivo: Normal distribution and elevation in acute and chronic infarction [J].
Flacke, SJ ;
Fischer, SE ;
Lorenz, CH .
RADIOLOGY, 2001, 218 (03) :703-710
[10]   Equilibrium Contrast Cardiovascular Magnetic Resonance for the Measurement of Diffuse Myocardial Fibrosis Preliminary Validation in Humans [J].
Flett, Andrew S. ;
Hayward, Martin P. ;
Ashworth, Michael T. ;
Hansen, Michael S. ;
Taylor, Andrew M. ;
Elliott, Perry M. ;
McGregor, Christopher ;
Moon, James C. .
CIRCULATION, 2010, 122 (02) :138-U72