A Multi-threaded Mosaicking Algorithm for Fast Image Composition of Fluorescence Bladder Images

被引:6
作者
Behrens, Alexander [1 ]
Bommes, Michael [1 ]
Stehle, Thomas [1 ]
Gross, Sebastian [1 ]
Leonhardt, Steffen [2 ]
Aach, Til [1 ]
机构
[1] Rhein Westfal TH Aachen, Inst Imaging & Comp Vis, Aachen, Germany
[2] Rhein Westfal TH Aachen Univ, Helmholtz Inst, Philips Chair Med Informat Technol, Aachen, Germany
来源
MEDICAL IMAGING 2010: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING | 2010年 / 7625卷
关键词
Bladder; Fluorescence Endoscopy; Image Mosaicking; Panorama; Image Composition;
D O I
10.1117/12.843685
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The treatment of urinary bladder cancer is usually carried out using fluorescence endoscopy. A narrow-band bluish illumination activates a tumor marker resulting in a red fluorescence. Because of low illumination power the distance between endoscope and bladder wall is kept low during the whole bladder scan, which is carried out before treatment. Thus, only a small field of view (FOV) of the operation field is provided, which impedes navigation and relocating of multi-focal tumors. Although off-line calculated panorama images can assist surgery planning, the immediate display of successively growing overview images composed from single video frames in real-time during the bladder scan, is well suited to ease navigation and reduce the risk of missing tumors. Therefore we developed an image mosaicking algorithm for fluorescence endoscopy. Due to fast computation requirements a flexible multi-threaded software architecture based on our RealTimeFrame platform is developed. Different algorithm tasks, like image feature extraction, matching and stitching are separated and applied by independent processing threads. Thus, different implementation of single tasks can be easily evaluated. In an optimization step we evaluate the trade-off between feature repeatability and total processing time, consider the thread synchronization, and achieve a constant workload of each thread. Thus, a fast computation of panoramic images is performed on a standard hardware platform, preserving full input image resolution (780x576) at the same time. Displayed on a second clinical monitor, the extended FOV of the image composition promises high potential for surgery assistance.
引用
收藏
页数:10
相关论文
共 16 条
[1]  
[Anonymous], Cancer Facts and Figures 2009
[2]   Speeded-Up Robust Features (SURF) [J].
Bay, Herbert ;
Ess, Andreas ;
Tuytelaars, Tinne ;
Van Gool, Luc .
COMPUTER VISION AND IMAGE UNDERSTANDING, 2008, 110 (03) :346-359
[3]  
Behrens A, 2008, ACTA POLYTECH, V48, P50
[4]   Local and Global Panoramic Imaging for Fluorescence Bladder Endoscopy [J].
Behrens, Alexander ;
Stehle, Thomas ;
Gross, Sebastian ;
Aach, Til .
2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, :6990-6993
[5]   RANDOM SAMPLE CONSENSUS - A PARADIGM FOR MODEL-FITTING WITH APPLICATIONS TO IMAGE-ANALYSIS AND AUTOMATED CARTOGRAPHY [J].
FISCHLER, MA ;
BOLLES, RC .
COMMUNICATIONS OF THE ACM, 1981, 24 (06) :381-395
[6]  
Gross S, 2008, ACTA POLYTECH, V48, P15
[7]  
GROSS S, 2007, 41 DGBMT JAHR BIOM T
[8]  
GROSS S, 2009, BIOMEDICA, P217
[9]  
HERNANDEZMIER Y, 2006, MODELING CONTROL BIO, V6
[10]  
KONEN W, 2007, BILDVERARBEITUNG MED