VOLUMETRIC-MODULATED ARC THERAPY FOR STEREOTACTIC BODY RADIOTHERAPY OF LUNG TUMORS: A COMPARISON WITH INTENSITY-MODULATED RADIOTHERAPY TECHNIQUES

被引:120
作者
Holt, Andrea [1 ]
van Vliet-Vroegindeweij, Corine [1 ]
Mans, Anton [1 ]
Belderbos, Jose S. [1 ]
Damen, Eugene M. F. [1 ]
机构
[1] Antoni Van Leeuwenhoek Hosp, Netherlands Canc Inst, Dept Radiat Oncol, NL-1066 CX Amsterdam, Netherlands
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2011年 / 81卷 / 05期
关键词
Lung cancer; stereotactic body radiotherapy; volumetric-modulated arc therapy; inverse-planned intensity-modulated radiotherapy; skin toxicity; CANCER;
D O I
10.1016/j.ijrobp.2010.09.014
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To demonstrate the potential of volumetric-modulated arc therapy (VMAT) compared with intensity-modulated radiotherapy (IMRT) techniques with a limited number of segments for stereotactic body radiotherapy (SBRT) for early-stage lung cancer. Methods and Materials: For a random selection of 27 patients eligible for SBRT, coplanar and noncoplanar IMRT and coplanar VMAT (using Smart Arc) treatment plans were generated in Pinnacle(3) and compared. In addition, film measurements were performed using an anthropomorphic phantom to evaluate the skin dose for the different treatment techniques. Results: Using VMAT, the delivery times could be reduced to an average of 6.6 min compared with 23.7 min with noncoplanar IMRT. The mean dose to the healthy lung was 4.1 Gy for VMAT and noncoplanar IMRT and 4.2 Gy for coplanar IMRT. The volume of healthy lung receiving > 5 Gy and > 20 Gy was 18.0% and 5.4% for VMAT, 18.5% and 5.0% for noncoplanar IMRT, and 19.4% and 5.7% for coplanar IMRT, respectively. The dose conformity at 100% and 50% of the prescribed dose of 54 Gy was 1.13 and 5.17 for VMAT, 1.11 and 4.80 for noncoplanar IMRT and 1.12 and 5.31 for coplanar IMRT, respectively. The measured skin doses were comparable for VMAT and noncoplanar IMRT and slightly greater for coplanar IMRT. Conclusions: Coplanar VMAT for SBRT for early-stage lung cancer achieved plan quality and skin dose levels comparable to those using noncoplanar IMRT and slightly better than those with coplanar IMRT. In addition, the delivery time could be reduced by <= 70% with VMAT. (C) 2011 Elsevier Inc.
引用
收藏
页码:1560 / 1567
页数:8
相关论文
共 15 条
[1]   Dose calculations accounting for breathing motion in stereotactic lung radiotherapy based on 4D-CT and the internal target volume [J].
Admiraal, Marjan A. ;
Schuring, Danny ;
Hurkmans, Coen W. .
RADIOTHERAPY AND ONCOLOGY, 2008, 86 (01) :55-60
[2]   Treatment planning for volumetric modulated arc therapy [J].
Bedford, James L. .
MEDICAL PHYSICS, 2009, 36 (11) :5128-5138
[3]   Development and evaluation of an efficient approach to volumetric arc therapy planning [J].
Bzdusek, Karl ;
Friberger, Henrik ;
Eriksson, Kjell ;
Hardemark, Bjorn ;
Robinson, David ;
Kaus, Michael .
MEDICAL PHYSICS, 2009, 36 (06) :2328-2339
[4]   Accurate skin dose measurements using radiochromic film in clinical applications [J].
Devic, S ;
Seuntjens, J ;
Abdel-Rahman, W ;
Evans, M ;
Olivares, M ;
Podgorsak, EB ;
Vuong, T ;
Soares, CG .
MEDICAL PHYSICS, 2006, 33 (04) :1116-1124
[5]   CHEST WALL VOLUME RECEIVING &gt;30 GY PREDICTS RISK OF SEVERE PAIN AND/OR RIB FRACTURE AFTER LUNG STEREOTACTIC BODY RADIOTHERAPY [J].
Dunlap, Neal E. ;
Cai, Jing ;
Biedermann, Gregory B. ;
Yang, Wensha ;
Benedict, Stanley H. ;
Sheng, Ke ;
Schefter, Tracey E. ;
Kavanagh, Brian D. ;
Larner, James M. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (03) :796-801
[6]   ACUTE SKIN TOXICITY FOLLOWING STEREOTACTIC BODY RADIATION THERAPY FOR STAGE I NON-SMALL-CELL LUNG CANCER: WHO'S AT RISK? [J].
Hoppe, Bradford S. ;
Laser, Benjamin ;
Kowalski, Alex V. ;
Fontenla, Sandra C. ;
Pena-Greenberg, Elizabeth ;
Yorke, Ellen D. ;
Lovelock, D. Michael ;
Hunt, Margie A. ;
Rosenzweig, Kenneth E. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (05) :1283-1286
[7]   Outcomes of risk-adapted fractionated stereotactic radiotherapy for stage I non-small-cell lung cancer [J].
Lagerwaard, Frank J. ;
Haasbeek, Cornelis J. A. ;
Smit, Egbert F. ;
Slotman, Ben J. ;
Senan, S. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (03) :685-692
[8]   3D Dosimetric verification of volumetric-modulated arc therapy by portal dosimetry [J].
Mans, Anton ;
Remeijer, Peter ;
Olaciregui-Ruiz, Igor ;
Wendling, Markus ;
Sonke, Jan-Jakob ;
Mijnheer, Ben ;
van Herk, Marcel ;
Stroom, Joep C. .
RADIOTHERAPY AND ONCOLOGY, 2010, 94 (02) :181-187
[9]   First clinical cone-beam CT imaging during volumetric modulated arc therapy [J].
Nakagawa, Keiichi ;
Haga, Akihiro ;
Shiraishi, Kenshiro ;
Yamashita, Hideomi ;
Igaki, Hiroshi ;
Terahara, Atsuro ;
Ohtomo, Kuni ;
Saegusa, Shigeki ;
Shiraki, Takashi ;
Oritate, Takashi ;
Yoda, Kiyoshi .
RADIOTHERAPY AND ONCOLOGY, 2009, 90 (03) :422-423
[10]   Volumetric modulated arc therapy: IMRT in a single gantry arc [J].
Otto, Karl .
MEDICAL PHYSICS, 2008, 35 (01) :310-317