Effect of Normal Forces on the Electrical Endurance of Tin-Plated Contacts Under Elevated Temperature Fretting Conditions

被引:1
|
作者
Lee, Doo-Jin [1 ]
Lee, Chae-Eun [2 ]
Kim, Ho-Kyung [3 ,4 ]
机构
[1] Seoul Natl Univ Sci & Technol, Grad Sch NID Fus Technol, Seoul 139743, South Korea
[2] Seoul Natl Univ Sci & Technol, Grad Sch, Dept Automot Engn, Seoul 139743, South Korea
[3] Seoul Natl Univ Sci & Technol, Dept Automot Engn, Seoul 139743, South Korea
[4] Seoul Natl Univ Sci & Technol, Dept Mech & Automot Engn, Seoul 139743, South Korea
来源
IEEE TRANSACTIONS ON COMPONENTS PACKAGING AND MANUFACTURING TECHNOLOGY | 2020年 / 10卷 / 07期
关键词
Electrical contacts; fretting corrosion; threshold displacement amplitude; CORROSION; FREQUENCY; AMPLITUDE; BEHAVIOR; WEAR;
D O I
10.1109/TCPMT.2020.3003016
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this article, an attempt is made to explore the effects of normal force and temperature on the threshold displacement amplitudes of tin-plated electrical contacts at elevated temperatures. Fretting tests were conducted at 323, 348, and 373 K at normal forces of 1, 1.25, 1.5, and 2 N. Riders and flats made from a 0.3-mm-thick brass sheet were coated with 10 mu m of tin. Dimples were commonly found at the center of the contact area of the test specimens corresponding to an unlimited lifetime. In the testing temperature range, the threshold displacement amplitude decreases with an increase in the temperature and with a decrease in the normal force. In this range, the threshold displacement amplitude was found to be controlled by the oxidation of a tin-plated surface. The activation energy was found to be 7.5 kJ/mole, which is close to the value of the activation energy for the growth of tin oxide film. The threshold displacement amplitude can be represented in the form of an Arrhenius equation and is proportional to the normal force.
引用
收藏
页码:1158 / 1165
页数:8
相关论文
共 50 条
  • [1] Fretting corrosion of tin-plated contacts
    Park, Young Woo
    Narayanan, T. S. N. Sankara
    Lee, Kang Yong
    TRIBOLOGY INTERNATIONAL, 2008, 41 (07) : 616 - 628
  • [2] Effects of temperature and span amplitude on fretting corrosion behavior of tin-plated electrical contacts
    Kim, Min-Jung
    Kim, Ho-Kyung
    MICROELECTRONICS RELIABILITY, 2017, 69 : 80 - 87
  • [3] Fretting corrosion of lubricated tin-plated contacts
    Narayanan, T. S. N. Sankara
    Park, Young Woo
    Lee, Kang Yong
    INDUSTRIAL LUBRICATION AND TRIBOLOGY, 2008, 60 (05) : 233 - 241
  • [4] Fretting corrosion of tin-plated contacts: Evaluation of surface characteristics
    Park, Young Woo
    Narayanan, T. S. N. Sankara
    Lee, Kang Yong
    TRIBOLOGY INTERNATIONAL, 2007, 40 (03) : 548 - 559
  • [5] Fretting effect on gold-plated and tin-plated surfaces
    Shao, Chunbo
    Zhang, Jigao
    Beijing Youdian Xueyuan Xuebao/Journal of Beijing University of Posts And Telecommunications, 1998, 21 (02): : 23 - 27
  • [6] Fretting-corrosion mapping of tin-plated copper alloy contacts
    Narayanan, T. S. N. Sankara
    Park, Young Woo
    Lee, Kang Yong
    WEAR, 2007, 262 (1-2) : 228 - 233
  • [7] Effect of normal forces on fretting corrosion of tin-coated electrical contacts
    Han, Dong-Woon
    Kim, Ho-Kyung
    MICROELECTRONICS RELIABILITY, 2017, 79 : 321 - 327
  • [8] Effect of temperature on the fretting corrosion of tin plated copper alloy contacts
    Park, Young Woo
    Narayanan, T. S. N. Sankara
    Lee, Kang Yong
    WEAR, 2007, 262 (3-4) : 320 - 330
  • [9] Development of empirical equations for fretting-corrosion failure-time of tin-plated contacts
    Park, Young Woo
    Lee, Kang Yong
    WEAR, 2008, 265 (5-6) : 756 - 762
  • [10] Fretting corrosion of lubricated tin plated copper alloy contacts: Effect of temperature
    Narayanan, T. S. N. Sankara
    Park, Young Woo
    Lee, Kang Yong
    TRIBOLOGY INTERNATIONAL, 2008, 41 (02) : 87 - 102