Horizontal Pull-Out Strength of Orthodontic Infrazygomatic Mini-Implant: An In Vitro Study

被引:13
作者
Chen, Chun-Ming [1 ]
Wu, Ju-Hui [2 ]
Lu, Pei-Chen [3 ]
Wang, Huang-Chi [4 ]
Lee, Huey-Er [2 ]
Wang, Chau-Hsiang [2 ]
Du, Je-Kang [4 ,5 ]
机构
[1] Kaohsiung Med Univ Hosp, Fac Dent, Coll Dent Med, Kaohsiung, Taiwan
[2] Kaohsiung Med Univ Hosp, Dept Family Dent, Kaohsiung, Taiwan
[3] Kaohsiung Med Univ Hosp, Dept Conservat Dent, Kaohsiung, Taiwan
[4] Kaohsiung Med Univ, Grad Inst Dent Sci, Coll Dent Med, Kaohsiung 807, Taiwan
[5] Kaohsiung Med Univ Hosp, Dept Prosthet Dent, Kaohsiung, Taiwan
关键词
infrazygomatic mini-implant; mechanical strength; orthodontic anchorage; CORTICAL BONE THICKNESS; TORQUE; ANCHORAGE; INSERTION; STABILITY;
D O I
10.1097/ID.0b013e31820fb7d4
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: New modified mini-implants have recently come into use for reinforcing skeletal anchorage in orthodontic application. The aim of this study was to investigate the influence of the design of a mini-implant on its mechanical strength. Materials and Methods: We measured the insertion torques and horizontal pull-out strengths of 3 brands of infrazygomatic mini-implants (AbsoAnchor, Bioray, and Lomas; 2 mm for all). Five implants of each brand were manually driven 6 mm into the artificial bone. Significant differences in various parameters among the brands were investigated with the Kruskal-Wallis test. Results: There was no significant relationship between insertion torque and horizontal pull-out strength. The Bioray mini-implants had significantly greater horizontal pull-out strength than the AbsoAnchor mini-implants. Conclusions: The design of the mini-implant can influence its insertion torque and horizontal pull-out strength. In our findings, the horizontal pull-out strength of all mini-implants placed in the infrazygomatic crest was significantly greater than the orthodontic force applied. (Implant Dent 2011; 20:139-145)
引用
收藏
页码:139 / 145
页数:7
相关论文
共 15 条
[1]   Pitch and Longitudinal Fluting Effects on the Primary Stability of Miniscrew Implants [J].
Brinley, Christine L. ;
Behrents, Rolf ;
Kim, Ki Beom ;
Condoor, Sridhar ;
Kyung, Hee-Moon ;
Buschang, Peter H. .
ANGLE ORTHODONTIST, 2009, 79 (06) :1156-1161
[2]   Effect of screw torque level on cortical bone pullout strength [J].
Cleek, Tammy M. ;
Reynolds, Karen J. ;
Hearn, Trevor C. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (02) :117-123
[3]  
Inceoglu Serkan, 2004, Spine J, V4, P513, DOI 10.1016/j.spinee.2004.02.006
[4]   Correction of deep overbite and gummy smile by using a mini-implant with a segmented wire in a growing Class 11 Division 2 patient [J].
Kim, Tae-Woo ;
Kim, Hyewon ;
Lee, Shin-Jae .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2006, 130 (05) :676-685
[5]   Root proximity is a major factor for screw failure in orthodontic anchorage [J].
Kuroda, Shingo ;
Yamada, Kazuyo ;
Deguchi, Toru ;
Hashimoto, Takashi ;
Kyung, Hee-Moon ;
Takano-Yamamoto, Teruko .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2007, 131 (04) :S68-S73
[6]   Insertion torque of orthodontic miniscrews according to changes in shape, diameter and length [J].
Lim, Seon-A ;
Cha, Jung-Yul ;
Hwang, Chung-Ju .
ANGLE ORTHODONTIST, 2008, 78 (02) :234-240
[7]   A computed tomographic image study on the thickness of the infrazygomatic crest of the maxilla and its clinical implications for miniscrew insertion [J].
Liou, Eric J. W. ;
Chen, Po-Hsun ;
Wang, Yu-Chih ;
Lin, James Chen-Yi .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2007, 131 (03) :352-356
[8]  
Motoyoshi M, 2007, INT J ORAL MAX IMPL, V22, P779
[9]   Cortical bone thickness in the buccal posterior region for orthodontic mini-implants [J].
Ono, A. ;
Motoyoshi, M. ;
Shimizu, N. .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2008, 37 (04) :334-340
[10]   Insertional torque and axial pull-out strength of mini-implants in mandibles of dogs [J].
Salmoria, Karine Kimak ;
Tanaka, Orlando Motohiro ;
Guariza-Filho, Odilon ;
Camargo, Elisa Souza ;
de Souza, Leandro Teixeira ;
Maruob, Hiroshi .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2008, 133 (06) :790.e15-790.e22