Facial Scanner Accuracy with Different Superimposition Methods: An In Vivo Study

被引:12
作者
da Silva Marques, Duarte Nuno [1 ,2 ]
Aparicio Aguiar Alves, Rita Vanessa [3 ]
Marques Pinto, Ricardo Jorge [3 ]
Bartolo Carames, Joao Rodrigo [1 ]
de Oliveira Francisco, Helena Cristina [4 ]
Mendez Carames, Joao Manuel [4 ]
机构
[1] Implantol Inst, Lisbon, Portugal
[2] Univ Lisbon, Fac Med Dent, Postgrad Program Prosthodont, Lisbon, Portugal
[3] Univ Lisbon, Implantol Inst, Postgrad Program Prosthodont, Fac Med Dent, Lisbon, Portugal
[4] Univ Lisbon, Implantol Inst, Postgrad Program Oral Surg & Implant Dent, Fac Med Dent, Lisbon, Portugal
关键词
REPRODUCIBILITY; RELIABILITY; VALIDATION; VALIDITY;
D O I
10.11607/ijp.7253
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To compare trueness and precision between conventional and digital facial measurements and to evaluate the accuracy of different superimposition techniques for facial scans. Materials and Methods: Twenty volunteers were recruited. Predetermined facial landmarks were marked with a black marker, and the interlandmark distances were measured manually with a conventional caliper and digitally with Geomagic software. Two consecutive facial scans were performed and then superimposed, using as best-fit reference the full face, the face without the eyes, and the bone-supported areas (eg, forehead and zygomatic areas) in order to assess root mean square (RMS) differences. Trueness and precision were evaluated and compared between the conventional and digital techniques. Mann-Whitney U and Kruskal-Wallis post hoc tests were used. The significance level was established as alpha = .05. Results: Trueness between conventional and digital measurements was 1,151.75 +/- 1,265.52 mu m (3.04% +/- 4.82%), and precision was 322.31 +/- 300.54 mu m (0.93% +/- 1.10%). Global mean RMS values for each superimposition technique were 334.15 +/- 172.07 for the full face, 339.57 +/- 173.13 for the face without the eyes, and 385.65 +/- 182.29 for the bone-supported areas, with the latter presenting statistically significant differences compared to the other two. Conclusion: Although statistically significant differences were detected in facial measurements, they were below the clinically detectable threshold. Superimposition with the full face and the face without the eyes area presented smaller discrepancies than with the bone-supported areas, with higher discrepancies in the lower third of the face.
引用
收藏
页码:578 / 584
页数:7
相关论文
共 31 条
[1]   The Accuracy of Digital Face Scans Obtained from 3D Scanners: An In Vitro Study [J].
Amornvit, Pokpong ;
Sanohkan, Sasiwimol .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2019, 16 (24)
[2]   A comparison between 2D and 3D methods of quantifying facial morphology [J].
Anas, I. Y. ;
Bamgbose, B. O. ;
Nuhu, Saleh .
HELIYON, 2019, 5 (06)
[3]   Soft tissue replication in single unit implant impressions-A three dimensional clinical study [J].
da Silva Marques, Duarte Nuno ;
Marques Pinto, Ricardo Jorge ;
Aparicio Aguiar Alves, Rita Vanessa ;
Baratieri, Luiz Narciso ;
Sola Pereira da Mata, Antonio Duarte ;
Mendez Carames, Joao Manuel .
JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2019, 31 (04) :359-368
[4]   Validity and reliability of a Portuguese version of the Summated Xerostomia Inventory-5 [J].
de Almeida Rato Amaral, Joao Pedro ;
da Silva Marques, Duarte Nuno ;
Thomson, William Murray ;
Rodrigues Vinagre, Alexandra Rosa ;
Sola Pereira da Mata, Antonio Duarte .
GERODONTOLOGY, 2018, 35 (01) :33-37
[5]   Smartphone Application as a Low-Cost Alternative for Digitizing Facial Defects: Is It Accurate Enough for Clinical Application? [J].
Elbashti, Mahmoud E. ;
Sumita, Yuka, I ;
Aswehlee, Amel M. ;
Seelaus, Rosemary .
INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2019, 32 (06) :541-543
[6]  
Fleiss J.L., 1985, DESIGN ANAL CLIN EXP
[7]  
Franco de Sa Gomes Camilla, 2019, J Oral Biol Craniofac Res, V9, P331, DOI 10.1016/j.jobcr.2019.07.001
[8]   Validation of a low-cost laser scanner device for the assessment of three-dimensional facial anatomy in living subjects [J].
Gibelli, Daniele ;
Pucciarelli, Valentina ;
Caplova, Zuzana ;
Cappella, Annalisa ;
Dolci, Claudia ;
Cattaneo, Cristina ;
Sforza, Chiarella .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2018, 46 (09) :1493-1499
[9]   Intraobserver Reliability of the 2-Dimensional Analysis of Facial Expressions [J].
Houstis, Odyssia ;
Dudic, Alexander ;
Kiliaridis, Stavros .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2010, 68 (07) :1498-1503
[10]   Application of Digital Anthropometry for Craniofacial Assessment [J].
Jayaratne, Yasas S. N. ;
Zwahlen, Roger A. .
CRANIOMAXILLOFACIAL TRAUMA & RECONSTRUCTION, 2014, 7 (02) :101-107