Wear rates of retentive versus nonretentive reverse total shoulder arthroplasty liners in an in vitro wear simulation

被引:14
作者
Carpenter, Shannon [1 ]
Pinkas, Daphne [1 ]
Newton, Michael D. [2 ]
Kurdziel, Michael D. [2 ,3 ]
Baker, Kevin C. [2 ,3 ]
Wiater, J. Michael [1 ,3 ]
机构
[1] Beaumont Hlth Syst, Dept Orthopaed Surg, Royal Oak, MI USA
[2] Beaumont Hlth Syst, Dept Orthopaed Res, Royal Oak, MI USA
[3] Oakland Univ, Dept Surg, William Beaumont Sch Med, Rochester, MI 48063 USA
关键词
Retentive humeral liners; reverse total shoulder arthroplasty; wear particle analysis; in vitro wear simulation; micro-CT surface deviation analysis; POLYETHYLENE WEAR; STABILITY; PROSTHESIS; COMPONENTS; REVISION; FRACTURE;
D O I
10.1016/j.jse.2015.02.016
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Although short-term outcomes of reverse total shoulder arthroplasty (rTSA) remain promising, the most commonly cited complication remains prosthetic instability. A retentive rTSA liner is commonly used to increase system constraint; however, no studies have evaluated the rate of polyethylene wear. Our hypothesis was that more constrained retentive liners would have higher wear rates than nonretentive liners. Methods: Six nonretentive and six retentive rTSA non-cross-linked polyethylene liners were subjected to 4.5 million cycles of alternating cycles of abduction-adduction and flexion-extension motion loading profiles. The rTSA liners were assessed for gravimetric wear loss, 3-dimensional volumetric loss by novel micro-computed tomography analysis, and particulate wear debris analysis. Results: Volumetric wear rates were significant at 7 specific time points (1.0, 2.0, 2.5, 3.25, 3.75, 4.0, and 4.5 million cycles) throughout testing between nonretentive and retentive liners; however, overall mean volumetric wear rate was not statistically significant (P = .076). Total volume loss between liner test groups was found to be significant starting after 3.5 million cycles of testing. Maximum and mean surface deviations were found to be larger for retentive liners vs. nonretentive liners by micro-computed tomography analysis across the entire articulation surface. Discussion and conclusion: Retentive liners undergo significantly greater volume loss and greater surface deviation compared with nonretentive liners, most notably at later time points representing extended implantation times. Additional stability afforded by retentive liners should be balanced against the potential for increased wear and potential for subsequent polyethylene wear-induced aseptic loosening. (C) 2015 Journal of Shoulder and Elbow Surgery Board of Trustees.
引用
收藏
页码:1372 / 1379
页数:8
相关论文
共 41 条
[1]  
Anderson M J, 1994, J Arthroplasty, V9, P17, DOI 10.1016/0883-5403(94)90133-3
[2]  
[Anonymous], P C SIM VIS SIMVIS
[3]   The long-term outcome of 755 consecutive constrained acetabular components in total hip arthroplasty - Examining the successes and failures [J].
Berend, KR ;
Lombardi, AV ;
Mallory, TH ;
Adams, JB ;
Russell, JH ;
Groseth, KL .
JOURNAL OF ARTHROPLASTY, 2005, 20 (07) :93-102
[4]   Grammont reverse prosthesis: Design, rationale, and biomechanics [J].
Boileau, P ;
Watkinson, DJ ;
Hatzidakis, AM ;
Balg, F .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2005, 14 (01) :147S-161S
[5]   Neer Award 2005: The Grammont reverse shoulder prosthesis: Results in cuff tear arthritis, fracture sequelae, and revision arthroplasty [J].
Boileau, Pascal ;
Watkinson, Duncan ;
Hatzidakis, Armodios M. ;
Hovorka, Istvan .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2006, 15 (05) :527-540
[6]   Validation of a micro-CT technique for measuring volumetric wear in retrieved acetabular liners [J].
Bowden, AE ;
Kurtz, SM ;
Edidin, AA .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2005, 75B (01) :205-209
[7]   Early dislocation after reverse total shoulder arthroplasty [J].
Chalmers, Peter N. ;
Rahman, Zain ;
Romeo, Anthony A. ;
Nicholson, Gregory P. .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2014, 23 (05) :737-744
[8]   Complications in Reverse Total Shoulder Arthroplasty [J].
Cheung, Emilie ;
Willis, Matthew ;
Walker, Matthew ;
Clark, Rachel ;
Frankle, Mark A. .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2011, 19 (07) :439-449
[9]   Infection associated with hematoma formation after shoulder arthroplasty [J].
Cheung, Emilie V. ;
Sperling, John W. ;
Cofield, Robert H. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2008, 466 (06) :1363-1367
[10]  
Cignoni P., 2008, P EUR IT CHAPT C SAL, P129, DOI [DOI 10.2312/LOCALCHAPTEREVENTS/ITALCHAP/ITALIANCHAPCONF2008/129-136, DOI 10.2312/LOCALCHAPTEREVENTS/ITALCHAP/ITALIANCHAPCONF2008]