A raw water source heat pump air-conditioning system

被引:50
作者
Cho, Yong [2 ]
Yun, Rin [1 ]
机构
[1] Hanbat Natl Univ, Dept Mech Eng, Taejon 305719, South Korea
[2] Korea Water Resources Corp, Water Inst K, Taejon 305730, South Korea
关键词
Raw-water source; Heat pump; Heating and cooling; Part load performance;
D O I
10.1016/j.enbuild.2011.07.028
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Raw water source is one of the promising new heat sources that researchers are looking into along with various others water-based sources such as ground, lake, river and sewage water. Generally, the water that is taken from the environment and supplied to a water treatment facility is called raw water. In this study, the heating and cooling performance of a heat pump utilizing the heat energy of raw water supplied to a water treatment facility is investigated. The two heat pumps being investigated have a heating capacity of 65.2 kW and were installed at the site for the heating and cooling of the central control room. A brazed plate heat exchanger was used for obtaining heat energy from the raw water. The raw water source provides a favorable heat source compared to the ambient air source except in spring. In the seasons of spring and autumn, the heating and cooling load are extremely low, this is the main reason for the poor performance of the raw-water heat pump system for those seasons. The average unit COP during the heating season is 3.3, and the average unit COP for the cooling season is 7.2. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:3068 / 3073
页数:6
相关论文
共 7 条
[1]   Underground water-source loop heat-pump air-conditioning system applied in a residential building in Beijing [J].
Chen, C ;
Sun, FL ;
Feng, L ;
Liu, M .
APPLIED ENERGY, 2005, 82 (04) :331-344
[2]  
Koo K., 2007, P C SOC AIR COND REF, P788
[3]   USING UNCERTAINTY ANALYSIS IN THE PLANNING OF AN EXPERIMENT [J].
MOFFAT, RJ .
JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 1985, 107 (02) :173-178
[4]   Development of dual-source hybrid heat pump system using groundwater and air [J].
Nam, Yujin ;
Ooka, Ryozo ;
Shiba, Yoshiro .
ENERGY AND BUILDINGS, 2010, 42 (06) :909-916
[5]   Numerical simulation of ground heat and water transfer for groundwater heat pump system based on real-scale experiment [J].
Nam, Yujin ;
Ooka, Ryozo .
ENERGY AND BUILDINGS, 2010, 42 (01) :69-75
[6]  
PERCHERS N, 2003, COMBINED HEATING COO, P700
[7]   Year round experimental study on a constant temperature and humidity air-conditioning system driven by ground source heat pump [J].
Yu, X. ;
Wang, R. Z. ;
Zhai, X. Q. .
ENERGY, 2011, 36 (02) :1309-1318