Sensitive gluten determination in gluten-free foods by an electrochemical aptamer-based assay

被引:38
作者
Amaya-Gonzalez, Sonia [1 ]
de-los-Santos-Alvarez, Noemi [1 ]
Miranda-Ordieres, Arturo J. [1 ]
Jesus Lobo-Castanon, Maria [1 ]
机构
[1] Univ Oviedo, Dept Quim Fis & Analit, Oviedo 33006, Spain
关键词
Aptamer; Coeliac disease; Electrochemical detection; Gliadin analysis; Gluten; 33-mer peptide; CELIAC-DISEASE; MONOCLONAL-ANTIBODY; GLIADIN; IMMUNOASSAYS; EXTRACTION; HEAT;
D O I
10.1007/s00216-015-8771-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Enzyme immunoassays are currently the methods of choice for gluten control in foods labelled as gluten free, providing a mechanism for assessing food safety for consumption by coeliac and other allergic patients. However, their limitations, many of them associated to the reactivity of the different antibodies used and their degree of specificity, have prevented the establishment of a standardised method of analysis. We explore new methods for quantitatively determining gluten content in foods based on the use of two recently described aptamers, raised against a 33-mer peptide recognised as the immunodominant fragment from alpha 2-gliadin. The assays use the target peptide immobilised onto streptavidin-coated magnetic beads in combination with a limited amount of biotin-aptamer in a competitive format, followed by streptavidin-peroxidase labelling of the aptamer that remains bound to the magnetic beads. The enzyme activity onto the beads, measured by chronoamperometry in disposable screen-printed electrodes, is inversely related to the target concentration in the test solution. We find that while the assay using the aptamer with the highest affinity towards the target (Gli 4) achieves low detection limits (similar to 0.5 ppm) and excellent analytical performance, when challenged in samples containing the intact protein, gliadin, it fails in detecting the peptide in solution. This problem is circumvented by employing another aptamer (Gli 1), the most abundant one in the SELEX pool, as a receptor. The proposed assays allow the convenient detection of the allergen in different kinds of food samples, including heat-treated and hydrolysed ones. The obtained results correlate with those of commercially available antibody-based assays, providing an alternative for ensuring the safety and quality of nominally gluten-free foods.
引用
收藏
页码:6021 / 6029
页数:9
相关论文
共 26 条
[1]  
Amaya-Gonzalez S, 2015, ANAL CHIM ACTA, V873, P73, DOI [10.1016/j.aca.2015.1002.1053, DOI 10.1016/J.ACA.2015.1002.1053]
[2]   Aptamer Binding to Celiac Disease-Triggering Hydrophobic Proteins: A Sensitive Gluten Detection Approach [J].
Amaya-Gonzalez, Sonia ;
de-los-Santos-Alvarez, Noemi ;
Miranda-Ordieres, Arturo J. ;
Jesus Lobo-Castanon, M. .
ANALYTICAL CHEMISTRY, 2014, 86 (05) :2733-2739
[3]   Amperometric Quantification of Gluten in Food Samples Using an ELISA Competitive Assay and Flow Injection Analysis [J].
Amaya-Gonzalez, Sonia ;
de-los-Santos-Alvarez, Noemi ;
Jesus Lobo-Castanon, Maria ;
Miranda-Ordieres, Arturo J. ;
Tunon-Blanco, Paulino .
ELECTROANALYSIS, 2011, 23 (01) :108-114
[4]   In vivo antigen challenge in celiac disease identifies a single transglutaminase-modified peptide as the dominant A-gliadin T-cell epitope [J].
Anderson, RP ;
Degano, P ;
Godkin, AJ ;
Jewell, DP ;
Hill, AVS .
NATURE MEDICINE, 2000, 6 (03) :337-342
[5]   Interference of denaturing and reducing agents on the antigen/antibody interaction.: Impact on the performance of quantitative immunoassays in gliadin analysis [J].
Dona, V. V. ;
Fossati, C. A. ;
Chirdo, F. G. .
EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2008, 226 (03) :591-602
[6]   Celiac disease, gluten-free diet, and oats [J].
Fric, Premysl ;
Gabrovska, Dana ;
Nevoral, Jiri .
NUTRITION REVIEWS, 2011, 69 (02) :107-115
[7]   Development of a general procedure for complete extraction of gliadins for heat processed and unheated foods [J].
García, E ;
Llorente, M ;
Hernando, A ;
Kieffer, R ;
Wieser, H ;
Méndez, E .
EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2005, 17 (05) :529-539
[8]   Gluten Fragment Detection with a Competitive ELISA [J].
Haas-Lauterbach, Sigrid ;
Immer, Ulrike ;
Richter, Mareike ;
Koehler, Peter .
JOURNAL OF AOAC INTERNATIONAL, 2012, 95 (02) :377-381
[9]   Magneto immunosensor for gliadin detection in gluten-free foodstuff: Towards food safety for celiac patients [J].
Laube, T. ;
Kergaravat, S. V. ;
Fabiano, S. N. ;
Hernandez, S. R. ;
Alegret, S. ;
Pividori, M. I. .
BIOSENSORS & BIOELECTRONICS, 2011, 27 (01) :46-52
[10]   Comprehensive analysis of gluten in processed foods using a new extraction method and a competitive ELISA based on the R5 antibody [J].
Mena, Maria C. ;
Lombardia, Manuel ;
Hernando, Alberto ;
Mendez, Enrique ;
Albar, Juan P. .
TALANTA, 2012, 91 :33-40