INTRA AND INTERSESSION RELIABILITY OF BALANCE MEASURES DURING ONE-LEG STANDING IN YOUNG ADULTS

被引:34
作者
Muehlbauer, Thomas [1 ,2 ]
Roth, Ralf [1 ]
Mueller, Sylvana [1 ]
Granacher, Urs [2 ]
机构
[1] Univ Basel, Inst Exercise & Hlth Sci, Basel, Switzerland
[2] Univ Jena, Inst Sport Sci, D-6900 Jena, Germany
关键词
postural control; center of pressure; test-retest reliability; intraclass correlation; HIGH-SCHOOL BASKETBALL; PRESSURE MEASURES; SPORTS INJURIES; FORCE-PLATFORM; INTRASESSION RELIABILITY; POSTURAL STEADINESS; PREVENTION STRATEGY; SWAY; GENERALIZABILITY; REDUCE;
D O I
10.1519/JSC.0b013e3181fb393b
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Muehlbauer, T, Roth, R, Mueller, S, and Granacher, U. Intra and intersession reliability of balance measures during one-leg standing in young adults. J Strength Cond Res 25(8): 2228-2234, 2011-A study was designed to investigate the intra and intersession reliability during 1-leg standing recorded from a computerized balance platform. Thirty-nine healthy young men (n = 17, age range: 20-30 years) and women (n = 22, age range: 21-28 years) performed 3 testing sessions, with the second session 30 minutes (intrasession comparison) and the third session 1 week (intersession comparison) after the initial testing session. Within each testing session, participants completed 3 trials of 1-leg standing with their dominant leg. Reliability statistics were calculated using the mean of all 3 trials during each session for 6 balance measures (i.e., total displacements of the center of pressure [CoP], the CoP displacements in mediolateral and anterior-posterior directions, and the CoP speed and CoP area and their SD). Test-retest reliability was examined calculating both, intraclass correlation coefficient (ICC) with 95% confidence interval (95% CI) and Bland-Altman plots. In both sexes and irrespective of balance measure, ICC values were >= 0.75 except for 1 parameter in men. This indicates an excellent intra and intersession reliability. Bland-Altman plots confirmed these findings by showing that only 1 or 2 (4.5-11.8%) of the data points were beyond the 95% CI. Practitioners and clinicians are provided with a posturographic test setup that proved to be reliable. Researchers can use these data to identify the range in which the true value of a subject's score lies and estimate a priori sample sizes.
引用
收藏
页码:2228 / 2234
页数:7
相关论文
共 34 条
[11]   Generalizability of center of pressure measures of quiet standing [J].
Doyle, Richard J. ;
Hsiao-Wecksler, Elizabeth T. ;
Ragan, Brian G. ;
Rosengren, Karl S. .
GAIT & POSTURE, 2007, 25 (02) :166-171
[12]   Reliability of traditional and fractal dimension measures of quiet stance center of pressure in young, healthy people [J].
Doyle, TL ;
Newton, RU ;
Burnett, AF .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2005, 86 (10) :2034-2040
[13]  
EKDAHL C, 1989, SCAND J REHABIL MED, V21, P187
[14]   The effectiveness of a neuromuscular prevention strategy to reduce injuries in youth soccer: a cluster-randomised controlled trial [J].
Emery, C. A. ;
Meeuwisse, W. H. .
BRITISH JOURNAL OF SPORTS MEDICINE, 2010, 44 (08) :555-562
[15]   Development of a clinical static and dynamic standing balance measurement tool appropriate for use in adolescents [J].
Emery, CA ;
Cassidy, JD ;
Klassen, TP ;
Rosychuk, RJ ;
Rowe, BH .
PHYSICAL THERAPY, 2005, 85 (06) :502-514
[16]   A prevention strategy to reduce the incidence of injury in high school basketball: A cluster randomized controlled trial [J].
Emery, Carolyn A. ;
Rose, M. Sarah ;
McAllister, Jenelle R. ;
Meeuwisse, Willem H. .
CLINICAL JOURNAL OF SPORT MEDICINE, 2007, 17 (01) :17-24
[17]   Postural balance in a random sample of 7,979 subjects aged 30 years and over [J].
Era, P. ;
Sainio, P. ;
Koskinen, S. ;
Haavisto, P. ;
Vaara, M. ;
Aromaa, A. .
GERONTOLOGY, 2006, 52 (04) :204-213
[18]   G*Power 3: A flexible statistical power analysis program for the social, behavioral, and biomedical sciences [J].
Faul, Franz ;
Erdfelder, Edgar ;
Lang, Albert-Georg ;
Buchner, Axel .
BEHAVIOR RESEARCH METHODS, 2007, 39 (02) :175-191
[19]   STEADINESS IN ONE-LEGGED STANCE - DEVELOPMENT OF A RELIABLE FORCE-PLATFORM TESTING PROCEDURE [J].
GOLDIE, PA ;
EVANS, OM ;
BACH, TM .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1992, 73 (04) :348-354
[20]  
Granacher U, 2010, J STRENGTH COND RES