Kranion, an open-source environment for planning transcranial focused ultrasound surgery: technical note

被引:28
作者
Sammartino, Francesco [1 ]
Beam, Dylan W. [1 ]
Snell, John [2 ]
Krishna, Vibhor [1 ]
机构
[1] Ohio State Univ, Ctr Neuromodulat, Columbus, OH 43210 USA
[2] Focused Ultrasound Fdn, Charlottesville, VA USA
关键词
focused ultrasound; surgical planning; temperature prediction; incision-less surgery; surgical technique;
D O I
10.3171/2018.11.JNS181995
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Transcranial focused ultrasound (FUS) ablation is an emerging incision-less treatment for neurological disorders. The factors affecting FUS treatment efficiency are not well understood. Kranion is open-source software that allows the user to simulate the planning stages of FUS treatment and to "replay" previous treatments for off-line analysis. This study aimed to investigate the relationship between skull parameters and treatment efficiency and to create a metric to estimate temperature rise during FUS. CT images from 28 patients were analyzed to validate the use of Kranion. For stereotactic targets within each patient, individual transducer element incident angles, skull density ratio, and skull thickness measurements were recorded. A penetration metric (the "beam index") was calculated by combining the energy loss from incident angles and the skull thickness. Kranion accurately estimated the patient's skull and treatment parameters. The authors observed significant changes in incident angles with different targets in the brain. Using the beam index as a predictor of temperature rise in a linear-mixed-effects model, they were able to predict the average temperature rise at the focal point during ablation with < 21% error (55 degrees C +/- 3.8 degrees C) in 75% of sonications, and with < 44% (55 degrees C +/- 7.9 degrees C) in 97% of sonications. This research suggests that the beam index can improve the prediction of temperature rise during FUS. Additional work is required to study the relationship between temperature rise and lesion shape and clinical outcomes.
引用
收藏
页码:1249 / 1255
页数:7
相关论文
共 10 条
[1]  
[Anonymous], C P IEEE ENG MED BIO
[2]  
[Anonymous], FOC ULTR FDN FDA APP
[3]  
[Anonymous], ULTRASONIC ATTENUATI
[4]   Factors associated with successful magnetic resonance guided focused ultrasound treatment: efficiency of acoustic energy delivery through the skull [J].
Chang, Won Seok ;
Jung, Hyun Ho ;
Zadicario, Eyal ;
Rachmilevitch, Itay ;
Tlusty, Tal ;
Vitek, Shuki ;
Chang, Jin Woo .
JOURNAL OF NEUROSURGERY, 2016, 124 (02) :411-416
[5]  
FRY F J, 1977, Ultrasound in Medicine and Biology, V3, P179, DOI 10.1016/0301-5629(77)90069-2
[6]  
FRY W J, 1954, J Neurosurg, V11, P471
[7]   ELECTRICAL SELF-STIMULATION OF BRAIN IN MAN [J].
HEATH, RG .
AMERICAN JOURNAL OF PSYCHIATRY, 1963, 120 (06) :571-&
[8]   PHASE-ABERRATION CORRECTION USING SIGNALS FROM POINT REFLECTORS AND DIFFUSE SCATTERERS - MEASUREMENTS [J].
ODONNELL, M ;
FLAX, SW .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1988, 35 (06) :768-774
[9]   Multi-frequency characterization of the speed of sound and attenuation coefficient for longitudinal transmission of freshly excised human skulls [J].
Pichardo, Samuel ;
Sin, Vivian W. ;
Hynynen, Kullervo .
PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (01) :219-250
[10]   Advances in functional and structural MR image analysis and implementation as FSL [J].
Smith, SM ;
Jenkinson, M ;
Woolrich, MW ;
Beckmann, CF ;
Behrens, TEJ ;
Johansen-Berg, H ;
Bannister, PR ;
De Luca, M ;
Drobnjak, I ;
Flitney, DE ;
Niazy, RK ;
Saunders, J ;
Vickers, J ;
Zhang, YY ;
De Stefano, N ;
Brady, JM ;
Matthews, PM .
NEUROIMAGE, 2004, 23 :S208-S219