Stereotactic body radiation therapy planning for liver tumors using functional images from dual-energy computed tomography

被引:5
作者
Ohira, Shingo [1 ,2 ]
Kanayama, Naoyuki [1 ]
Toratani, Masayasu [1 ]
Ueda, Yoshihiro [1 ]
Koike, Yuhei [3 ]
Karino, Tsukasa [1 ]
Shunsuke, Ono [1 ]
Miyazaki, Masayoshi [1 ,4 ]
Koizumi, Masahiko [2 ]
Teshima, Teruki [1 ]
机构
[1] Osaka Int Canc Inst, Dept Radiat Oncol, Osaka, Japan
[2] Osaka Univ, Dept Med Phys & Engn, Grad Sch Med, Suita, Osaka, Japan
[3] Osaka Univ, Dept Radiat Oncol, Grad Sch Med, Suita, Osaka, Japan
[4] Hyogo Coll Med, Dept Radiol, Nishinomiya, Hyogo, Japan
关键词
SBRT; Liver; DECT; Fibrosis; Function; CHRONIC HEPATITIS-B; HEPATOCELLULAR-CARCINOMA; FIBROSIS; LUNG; CT; ELASTOGRAPHY; RADIOTHERAPY; PERFORMANCE; AVOIDANCE; REDUCTION;
D O I
10.1016/j.radonc.2019.12.002
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: This study aimed to generate a functional image of the liver using dual-energy computed tomography (DECT) and a functional-image-based stereotactic body radiation therapy plan to minimize the dose to the volume of the functional liver (V-fl). Material and methods: A normalized iodine density (NID) map was generated for fifteen patients with liver tumors. The volume of liver with an NID < 0.46 was defined as V-fl, and the ratio between Vfl and the total volume of the liver (FLR) was calculated. The relationship between the FLR and Fibrosis-4 (FIB-4) was assessed. For patients with 15% < FLR < 85%, functional volumetric modulated-arc therapy plans (F-VMAT) were retrospectively generated to preserve V-fl, and compared to the clinical plans (C-VMAT). Results: FLR showed a significantly strong correlation with FIB-4 (r = -0.71, p < 0.01). For ten generated F-VMAT plans, the dosimetric parameters of D-99%, D-50%, D-1% and the conformity index were comparable to those of the C-VMAT (p > 0.05). For V-fl, F-VMAT plans achieved lower V-5Gy (122.4 +/- 31.7 vs 181.1 +/- 57.3 cc), V-10Gy (44.4 +/- 22.2 vs 98.2 +/- 33.3 cc), V-15Gy (22.6 +/- 20.3 vs 49.8 +/- 33.7 cc), V-20Gy (11.6 +/- 14.1 vs 24.9 +/- 25.1 cc), and D-mean (3.9 +/- 2.3 vs 5.8 +/- 3.0 Gy) values than the C-VMAT plans (p < 0.01). Conclusions: The functional image derived from DECT was successfully used, allowing for a reduction in the dose to the V-fl without compromising target coverage. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:56 / 62
页数:7
相关论文
共 35 条
  • [1] Liver Fibrosis Staging with MR Elastography: Comparison of Diagnostic Performance between Patients with Chronic Hepatitis B and Those with Other Etiologic Causes
    Chang, Won
    Lee, Jeong Min
    Yoon, Jeong Hee
    Han, Joon Koo
    Choi, Byung Ihn
    Yoon, Jung Hwan
    Lee, Kyoung Bun
    Lee, Kwang-Woong
    Yi, Nam-Joon
    Suh, Kyung-Suk
    [J]. RADIOLOGY, 2016, 280 (01) : 88 - 97
  • [2] Hepatobiliary scintigraphy allows the evaluation of short-term functional toxicity of liver stereotactic body radiotherapy: Results of a pilot study
    De Bari, Berardino
    Breuneval, Thomas
    Zeverino, Michele
    Godin, Sarah
    Deantonio, Letizia
    Geldhof, Christine
    Bourhis, Jean
    Schaefer, Nicklaus
    Moeckli, Raphael
    Prior, John
    Ozsahin, Mahmut
    [J]. PLOS ONE, 2018, 13 (10):
  • [3] Dietrich CF, 2017, ULTRASCHALL MED, V38, pE52, DOI [10.1055/s-0043-103952, 10.1055/a-0641-0076]
  • [4] Iodine density Changes in Hepatic and Splenic Parenchyma in Liver Cirrhosis with Dual Energy CT (DECT): A Preliminary Study
    Dong, Jian
    He, Fuliang
    Wang, Lei
    Yue, Zhendong
    Wen, Tingguo
    Wang, Rengui
    Liu, Fuquan
    [J]. ACADEMIC RADIOLOGY, 2019, 26 (07) : 872 - 877
  • [5] Evaluating the Toxicity Reduction With Computed Tomographic Ventilation Functional Avoidance Radiation Therapy
    Faught, Austin M.
    Miyasaka, Yuya
    Kadoya, Noriyuki
    Castillo, Richard
    Castillo, Edward
    Vinogradskiy, Yevgeniy
    Yamamoto, Tokihiro
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : 325 - 333
  • [6] Accuracy of Real-Time Shear Wave Elastography for Assessing Liver Fibrosis in Chronic Hepatitis C: A Pilot Study
    Ferraioli, Giovanna
    Tinelli, Carmine
    Dal Bello, Barbara
    Zicchetti, Mabel
    Filice, Gaetano
    Filice, Carlo
    [J]. HEPATOLOGY, 2012, 56 (06) : 2125 - 2133
  • [7] Conformity index:: A review
    Feuvret, L
    Noël, G
    Mazeron, JJ
    Bey, P
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 64 (02): : 333 - 342
  • [8] Performance of Acoustic Radiation Force Impulse imaging for the staging of liver fibrosis: a pooled meta-analysis
    Friedrich-Rust, M.
    Nierhoff, J.
    Lupsor, M.
    Sporea, I.
    Fierbinteanu-Braticevici, C.
    Strobel, D.
    Takahashi, H.
    Yoneda, M.
    Suda, T.
    Zeuzem, S.
    Herrmann, E.
    [J]. JOURNAL OF VIRAL HEPATITIS, 2012, 19 (02) : E212 - E219
  • [9] Hepatocellular carcinoma in cirrhotic patients at multidetector CT: hepatic venous phase versus delayed phase for the detection of tumour washout
    Furlan, A.
    Marin, D.
    Vanzulli, A.
    Patera, G. Palermo
    Ronzoni, A.
    Midiri, M.
    Bazzocchi, M.
    Lagalla, R.
    Brancatelli, G.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2011, 84 (1001) : 403 - 412
  • [10] A mid-treatment break and reassessment maintains tumor control and reduces toxicity in patients with hepatocellular carcinoma treated with stereotactic body radiation therapy
    Jackson, W. C.
    Suresh, K.
    Maurino, C.
    Feng, M.
    Cuneo, K. C.
    Ten Haken, R. K.
    Lawrence, T. S.
    Schipper, M. J.
    Owen, D.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2019, 141 : 101 - 107