Counterflow heat exchanger with core and plenums at both ends

被引:12
作者
Bejan, A. [1 ]
Alalaimi, M. [1 ]
Lorente, S. [2 ]
Sabau, A. S. [3 ]
Klett, J. W. [3 ]
机构
[1] Duke Univ, Durham, NC 27708 USA
[2] Univ Toulouse, INSA, 135 Ave Rangueil, F-31077 Toulouse, France
[3] Oak Ridge Natl Lab, Oak Ridge, TN 37830 USA
基金
美国能源部;
关键词
Constructal; Heat exchanger; Counterflow; Crossflow; Morphing; DESIGN; OPTIMIZATION; SURFACES;
D O I
10.1016/j.ijheatmasstransfer.2016.03.117
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper illustrates the morphing of flow architecture toward greater performance in a counterflow heat exchanger. The architecture consists of two plenums with a core of counterflow channels between them. Each stream enters one plenum and then flows in a channel that travels the core and crosses the second plenum. The volume of the heat exchanger is fixed while the volume fraction occupied by each plenum is variable. Performance is driven by two objectives, simultaneously: low flow resistance and low thermal resistance. The analytical and numerical results show that the overall flow resistance is the lowest when the core is absent, and each plenum occupies half of the available volume and is oriented in counterflow with the other plenum. In this configuration, the thermal resistance also reaches its lowest value. These conclusions hold for fully developed laminar flow and turbulent flow through the core. The curve for effectiveness vs number of heat transfer units (N-tu) is steeper (when N-tu < 1) than the classical curves for counterflow and crossflow. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:622 / 629
页数:8
相关论文
共 50 条
  • [21] Numerical Investigation and Machine Learning-Based Prediction of the Effect of Using Ring Turbulators on Heat Transfer Characteristics in a Counterflow Heat Exchanger
    Solmaz Ö.
    Baysal E.
    Ökten M.
    Recent Innovations in Chemical Engineering, 2023, 16 (05) : 362 - 378
  • [22] Data analysis for performance index of plate heat exchanger filled by ionanofluid-oil: parallel versus counterflow
    Zahan, Ishrat
    Nasrin, Rehena
    Jakia, Nusrat Jahan
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [23] Study on structure optimization of heat exchanger and evaluation index of heat transfer performance
    Liu X.
    Zhang S.
    Zhou Z.
    Zheng H.
    Wang C.
    Shi H.
    Li M.
    Huagong Xuebao/CIESC Journal, 2020, 71 : 98 - 105
  • [24] Performance analysis of heat exchanger for fluids with variable properties
    Guo, Jiangfeng
    Cui, Xinying
    Zhang, Haiyan
    Huai, Xiulan
    Cheng, Keyong
    INNOVATIVE SOLUTIONS FOR ENERGY TRANSITIONS, 2019, 158 : 5724 - 5734
  • [25] Performance enhancement of cabinet cooling system by utilizing cross-flow plate heat exchanger
    Borjigin, Saranmanduh
    Zhang, Shuxiong
    Ma, Ting
    Zeng, Min
    Wang, Qiuwang
    ENERGY CONVERSION AND MANAGEMENT, 2020, 213 (213)
  • [26] Heat transfer intensification for retrofitting heat exchanger networks with considering exchanger detailed performances
    Pan, Ming
    Bulatov, Igor
    Smith, Robin
    AICHE JOURNAL, 2018, 64 (06) : 2052 - 2077
  • [27] On the optimum heat exchanger sizing for heat recovery
    Söylemez, MS
    ENERGY CONVERSION AND MANAGEMENT, 2000, 41 (13) : 1419 - 1427
  • [28] Waste heat recovery through plate heat exchanger based thermoelectric generator system
    Wang, Tongcai
    Luan, Weiling
    Wang, Wei
    Tu, Shan-Tung
    APPLIED ENERGY, 2014, 136 : 860 - 865
  • [29] Optimization of heat exchanger network
    Gorji-Bandpy, Mofid
    Yahyazadeh-Jelodar, Hossein
    Khalili, Mohammadtaghi
    APPLIED THERMAL ENGINEERING, 2011, 31 (05) : 779 - 784
  • [30] Entropy generation rate in counter-flow heat exchanger (influence of heat exchanger effectiveness)
    Ogiso, K
    HEAT TRANSFER SCIENCE AND TECHNOLOGY 2000, 2000, : 686 - 690