TOWARDS QUANTIFICATION OF KIDNEY STONES USING X-RAY DARK-FIELD TOMOGRAPHY

被引:0
|
作者
Hu, S. [1 ,2 ]
Yang, F. [3 ,5 ]
Griffa, M. [3 ]
Kaufmann, R. [3 ]
Anton, G. [4 ]
Maier, A. [1 ,2 ]
Riess, C. [1 ]
机构
[1] Univ Erlangen Nurnberg, Pattern Recognit Lab, Erlangen, Germany
[2] Univ Erlangen Nurnberg, Erlangen Grad Sch Adv Opt Technol SAOT, Erlangen, Germany
[3] EMPA, Construct Chem Lab, Ctr Xray Analyt & Concrete, Dubendorf, Switzerland
[4] Univ Erlangen Nurnberg, ECAP, Erlangen, Germany
[5] Swiss Fed Inst Technol, Swiss Fed Inst Technol Zurich, Zurich, Switzerland
来源
2017 IEEE 14TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2017) | 2017年
关键词
X-ray imaging; kidney; Image reconstruction analytical & iterative methods; URINARY-TRACT CALCULI; RECONSTRUCTION; MINIMIZATION;
D O I
暂无
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Kidney stones is a renal disease with high prevalence and one of the major reasons for emergency room visits. The prevalence of kidney stones is increasing, and the lifetime recurrence rate is estimated as almost 50%. Thus, treatment of kidney stones becomes an increasingly important topic. However, different types of kidney stones require specific treatments, which creates the need for accurate diagnosis of the stone type prior to the intervention. Imaging techniques that are commonly used for the detection of kidney stones, such as X-ray CT and ultrasound, are insufficient to differentiate the types of kidney stones. In this paper, we present a proof-of-concept study for differentiating kidney stones using X-ray dark-field tomography. The most important advantage of this method is its ability to image non-homogeneous kidney stones, i.e., to localize and identify the individual components of mixed-material kidney stones. We use a weighted total-variation regularized reconstruction method to compute the ratio of dark-field over absorption signal (DA Ratio) from noisy projections. We evaluate the performance of the proposed approach on two kidney stones of homogeneous composition, and one well-defined numerical phantom with known ground truth for mixed types of stones. We illustrate that the DA Ratio is significantly distinguished for different materials from the experiments. Reconstruction of phantom data recovers voxel-wise material information with high accuracy. We show that X-ray dark-field tomography has a significant potential in selective characterization of kidney stones.
引用
收藏
页码:1112 / 1115
页数:4
相关论文
共 50 条
  • [1] Artifacts in X-ray Dark-Field Tomography
    Modregger, P.
    Wang, Z.
    Thuering, T.
    Pinzer, B.
    Stampanoni, M.
    10TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2011, 1365 : 269 - 272
  • [2] Tissue Visualization Using X-Ray Dark-Field Imaging towards Pathological Goal
    Ando, Masami
    Chikaura, Yoshinori
    Endo, Tokiko
    Gupta, Rajiv
    Huo, Qingkai
    Hyodo, Kazuyuki
    Ichihara, Shu
    Mori, Kensaku
    Nakao, Yuki
    Ohura, Norihiko
    Sunaguchi, Naoki
    Sugiyama, Hiroshi
    Suzuki, Yoshifumi
    Wu, Yanlin
    Yuasa, Tetsuya
    Zhang Xiaowei
    11TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI 2012), 2013, 425
  • [3] Optimization of in vivo murine X-ray dark-field computed tomography
    Umkehrer, Stephan
    Birnbacher, Lorenz
    Burkhardt, Rico
    von Teuffenbach, Maximilian
    Yildirim, Ali Onder
    Pfeiffer, Daniela
    Herzen, Julia
    Pfeiffer, Franz
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2019, 90 (10)
  • [4] Dark-field hyperspectral X-ray imaging
    Egan, Christopher K.
    Jacques, Simon D. M.
    Connolley, Thomas
    Wilson, Matthew D.
    Veale, Matthew C.
    Seller, Paul
    Cernik, Robert J.
    PROCEEDINGS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2014, 470 (2165):
  • [5] Artifacts in X-ray dark-field measurements
    Horn, Florian
    Bayer, Florian
    Goedel, Karl
    Haas, Wilhelm
    Pelzer, Georg
    Rieger, Jens
    Ritter, Andre
    Weber, Thomas
    Zang, Andrea
    Durst, Juergen
    Michel, Thilo
    Anton, Gisela
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [6] X-ray refraction-contrast computed tomography images using dark-field imaging optics
    Sunaguchi, Naoki
    Yuasa, Tetsuya
    Huo, Qingkai
    Ichihara, Shu
    Ando, Masami
    APPLIED PHYSICS LETTERS, 2010, 97 (15)
  • [7] Review and experimental verification of x-ray dark-field signal interpretations with respect to quantitative isotropic and anisotropic dark-field computed tomography
    Graetz, J.
    Balles, A.
    Hanke, R.
    Zabler, S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (23)
  • [8] X-ray dark-field imaging with a single absorption grating
    Yang, Jun
    Zong, Fangke
    Lei, Yaohu
    Huang, Jianheng
    Liu, Jinyuan
    Guo, Jinchuan
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2019, 52 (19)
  • [9] Simulations of dislocation contrast in dark-field X-ray microscopy
    Borgi, Sina
    Raeder, Trygve Magnus
    Carlsen, Mads Allerup
    Detlefs, Carsten
    Winther, Grethe
    Poulsen, Henning Friis
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2024, 57 (Pt 2) : 358 - 368
  • [10] Simulation study towards quantitative X-ray and neutron tensor tomography regarding the validity of linear approximations of dark-field anisotropy
    Graetz, Jonas
    SCIENTIFIC REPORTS, 2021, 11 (01)