Accurate mass screening of pharmaceuticals and fungicides in water by U-HPLC-Exactive Orbitrap MS

被引:48
作者
Chitescu, Carmen Lidia [1 ]
Oosterink, Efraim [2 ]
de Jong, Jacob [2 ]
Stolker, Alida Adriana Maria [2 ]
机构
[1] Dunarea de Jos Univ Galati, Fac Food Sci & Engn, Galati 800201, Romania
[2] RIKILT Wageningen Univ & Res, NL-6700 AE Wageningen, Netherlands
关键词
Antibiotics; Antifungal compounds; Water contamination; Mass accuracy; Post-target approach; Multi-residue analysis; LIQUID-CHROMATOGRAPHY; ANTIFUNGAL AGENTS; SURFACE-WATER; ANTIBIOTICS; RESISTANCE; SPECTROMETRY; GROUNDWATER; SUPPRESSION; RESIDUES; TIME;
D O I
10.1007/s00216-012-5888-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The use of pharmaceuticals in livestock production is a potential source of surface water, groundwater and soil contamination. Possible impacts of antibiotics on the environment include toxicity and the emergence of antibiotic resistance. Monitoring programs are required to record the presence of these substances in the environment. A rapid, versatile and selective multi-method was developed and validated for screening 43 pharmaceutical and fungicides compounds, in surface and groundwater, in one single full-scan MS method, using benchtop U-HPLC-Exactive Orbitrap MS at 50,000 (FWHM) resolution. Detection was based on calculated exact masses and on retention time. Sample volume, pH conditions and solid-phase extraction (SPE) sample clean-up conditions were optimized. In the final method, 74 % of the compounds had recoveries higher than 80 %, 15 % of the compounds had recoveries between 60 % and 80 %, and 7 % of the compounds had recoveries between 40 % and 50 %. One of the compounds (itraconazole) had a recovery lower than 10 % and nystatin was not detected. The level of detection was 10 ng L-1 for 61 % of the compounds, 50 ng L-1 for 32 % and 100 ng L-1 for 5%. In-house validation, based on EU guidelines, proves that the detection capability CC beta is lower than 10 ng L-1 (for beta error 5 %) for 37 % of the compounds, lower than 50 ng L-1 for 35 % of the compounds and lower than 100 ng L-1 for 14 % of compounds. This study demonstrates that the ultra-high resolution and reliable mass accuracy of Exactive Orbitrap MS permits the detection of pharmaceutical residues in a concentration range of 10-100 ng L-1, applying a post target screening approach, in the multi-method conditions.
引用
收藏
页码:2997 / 3011
页数:15
相关论文
共 33 条
[1]  
[Anonymous], OFF J EUR COMMUN L
[2]  
[Anonymous], CVMPERA4182822005 EM
[3]  
[Anonymous], P60128TR R D
[4]  
[Anonymous], THESIS GUJARAT AGR U
[5]  
[Anonymous], THESIS ANAND AGR U A
[6]   Simultaneous analysis of multiple classes of antibiotics by ion trap LC/MS/MS for assessing surface water and groundwater contamination [J].
Batt, AL ;
Aga, DS .
ANALYTICAL CHEMISTRY, 2005, 77 (09) :2940-2947
[7]   Antifungal Drug Resistance - Concerns for Veterinarians [J].
Bhanderi, Bharat B. ;
Yadav, Mahendra Mohan ;
Roy, Ashish .
VETERINARY WORLD, 2009, 2 (05) :204-207
[8]   Fast and robust simultaneous determination of three veterinary antibiotics in groundwater and surface water using a tandem solid-phase extraction with high-performance liquid chromatography-UV detection [J].
Blackwell, PA ;
Lützhoft, HCH ;
Ma, HP ;
Halling-Sorensen, B ;
Boxall, ABA ;
Kay, P .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1045 (1-2) :111-117
[9]  
Connors K. A., 1986, Chemical Stability of Pharmaceuticals, A Handbook for Pharmacists
[10]  
EC, 2010, GUID VAL SCREEN METH