Characteristics of implant-CAD/CAM abutment connections of two different internal connection systems

被引:41
作者
Sumi, T. [2 ]
Braian, M. [1 ]
Shimada, A. [3 ]
Shibata, N. [2 ]
Takeshita, K.
Vandeweghe, S. [1 ,4 ]
Coelho, P. G. [5 ]
Wennerberg, A. [1 ]
Jimbo, R. [1 ]
机构
[1] Malmo Univ, Fac Odontol, Dept Prosthodont, S-20506 Malmo, Sweden
[2] Aichi Gakuin Univ, Dept Fixed Prosthodont, Nagoya, Aichi, Japan
[3] Univ Aarhus, Sch Dent, Dept Clin Oral Physiol, Aarhus, Denmark
[4] Univ Ghent, Fac Med & Hlth Sci, Sch Dent, Dept Periodontoloy & Oral Implantol, Ghent, Belgium
[5] NYU, Dept Biomat & Biomimet, New York, NY USA
关键词
computer-aided design; computer-aided manufacturing abutment; internal connection; microscopic analysis; misfit; FINITE-ELEMENT-ANALYSIS; SCREW JOINT STABILITY; EXTERNAL-HEX IMPLANT; IN-VITRO EVALUATION; BIOMECHANICAL ASPECTS; INTERFACE; BONE; INFLAMMATION; PROSTHESES; MORPHOLOGY;
D O I
10.1111/j.1365-2842.2011.02273.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Titanium or zirconium computer-aided design/computer-aided manufacturing abutments are now widely used for aesthetic implant treatments; however, information regarding microscopic structural differences that may influence the biological and mechanical outcomes of different implant systems is limited. Therefore, the characteristics of different connection systems were investigated. Optical microscopic observation and scanning electron microscopy showed different characteristics of two internal systems, namely the Astra Tech and the Replace Select system, and for different materials. The scanning electron microscopic observation showed for the Astra Tech that the implantabutment interface seemed to be completely sealed for both titanium and zirconium abutments, both horizontally and sagittally; however, the first implantabutment contact was below the fixture top, creating a microgap, and fixtures connected with titanium abutments showed significantly larger values (23.56 mu m +/- 5.44 in width, and 168.78 mu m +/- 30.39 in depth, P < 0.001). For Replace Select, scanning electron microscopy in the sagittal direction showed that the sealing of titanium and zirconium abutments differed. The seal between the implanttitanium and implantzirconium abutments seemed to be complete at the butt-joint interface; however, the displacement of the abutment in relation to the fixture in the lateral direction was evident for both abutments with no statistical differences (P > 0.70), creating an inverted microgap. Thus, microscopy evaluation of two commonly used internal systems connected to titanium or zirconium abutments showed that the implantabutment interface was perfectly sealed under no-loading conditions. However, an inverted microgap was seen in both systems, which may result in bacterial accumulation as well as alteration of stress distribution at the implantabutment interface.
引用
收藏
页码:391 / 398
页数:8
相关论文
共 37 条
[1]  
Albrektsson T, 2009, INT J PROSTHODONT, V22, P120
[2]  
Binon PP, 1996, INT J PROSTHODONT, V9, P149
[3]  
Binon PP, 1996, INT J PROSTHODONT, V9, P511
[4]   Peri-implant inflammation defined by the implant-abutment interface [J].
Broggini, N ;
McManus, LM ;
Hermann, JS ;
Medina, R ;
Schenk, RK ;
Buser, D ;
Cochran, DL .
JOURNAL OF DENTAL RESEARCH, 2006, 85 (05) :473-478
[5]   Persistent acute inflammation at the implant-abutment interface [J].
Broggini, N ;
McManus, LM ;
Hermann, JS ;
Medina, RU ;
Oates, TW ;
Schenk, RK ;
Buser, D ;
Mellonig, JT ;
Cochran, DL .
JOURNAL OF DENTAL RESEARCH, 2003, 82 (03) :232-237
[6]   Biomechanical Aspects of Bone-Level Diameter Shifting at Implant-Abutment Interface [J].
Canay, Senay ;
Akca, Kivanc .
IMPLANT DENTISTRY, 2009, 18 (03) :239-244
[7]   Implant design and interface force transfer - A photoelastic and strain-gauge analysis [J].
Cehreli, M ;
Duyck, J ;
De Cooman, M ;
Puers, R ;
Naert, I .
CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (02) :249-257
[8]  
Chun HJ, 2006, INT J ORAL MAX IMPL, V21, P195
[9]   Cross-sectional analysis of the implant-abutment interface [J].
Coelho, A. L. ;
Suzuki, M. ;
Dibart, S. ;
Da Silva, N. ;
Coelho, P. G. .
JOURNAL OF ORAL REHABILITATION, 2007, 34 (07) :508-516
[10]   In vitro evaluation of the implant abutment connection sealing capability of different implant systems [J].
Coelho, P. G. ;
Sudack, P. ;
Suzuki, M. ;
Kurtz, K. S. ;
Romanos, G. E. ;
Silva, N. R. F. A. .
JOURNAL OF ORAL REHABILITATION, 2008, 35 (12) :917-924