Cascaded voltage-current control;
droop control of inverters;
parallel operation;
virtual inductance;
virtual flux droop control;
voltage source inverter;
CONTROL STRATEGY;
CONNECTED INVERTERS;
DESIGN;
D O I:
10.1109/TPEL.2018.2834621
中图分类号:
TM [电工技术];
TN [电子技术、通信技术];
学科分类号:
0808 ;
0809 ;
摘要:
In this paper, a simple controller configuration for the decentralized parallel operation of single-phase inverters in stand-alone ac supply systems is proposed. The configuration is designed considering the unavailability of the filter capacitor voltage and grid current information to the controller. Due to the unavailability of voltage information, internally estimated voltage references and the measured value of the converter-side inductor current are used for the calculation of the active and reactive power. Frequency and voltage droop characteristics are used, and hence, communication is not required. The operation of the inverter at the reference voltage magnitude and frequency is achieved by the direct control of the modulating wave. Therefore, inability to implement closed loops caused by the absence of certain voltage and current information is mitigated. The proposed controller has the provision for protection of switching devices during overcurrent situation. The accuracy and feasibility of the proposed controller are validated using the simulation and experimental results.
Goestan S, 2013, 4TH ANNUAL INTERNATIONAL POWER ELECTRONICS, DRIVE SYSTEMS & TECHNOLOGIES CONFERENCE (PEDSTC 2013), P510, DOI 10.1109/PEDSTC.2013.6506761
Goestan S, 2013, 4TH ANNUAL INTERNATIONAL POWER ELECTRONICS, DRIVE SYSTEMS & TECHNOLOGIES CONFERENCE (PEDSTC 2013), P510, DOI 10.1109/PEDSTC.2013.6506761