Drilling with 3D Fluoroscopic Navigation in osteonecrosis of the femoral condyle

被引:8
|
作者
Citak, M. [1 ]
Kendoff, D. [1 ]
Stuebig, T. [1 ]
Krettek, C. [1 ]
Huefner, T. [1 ]
机构
[1] Medizin Hsch, Unfallchirurg Klin, D-30625 Hannover, Germany
来源
UNFALLCHIRURG | 2008年 / 111卷 / 05期
关键词
navigation; image fusion; ISO-C(3D); MRI scan; osteonecrosis;
D O I
10.1007/s00113-007-1353-0
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The primary goal of drilling procedures for the treatment of osteonecrotic lesions is revascularisation of the defect area. In the literature good results are reported for this technique in 70% of cases. Precise drilling of the necrosed area as part of a minimally invasive technique does, however, require unequivocal intraoperative identification of the region visually, either by arthroscopy or by fluoroscopy. In the case of inadequate imaging, as in our case, there is no longer any guarantee of precise drilling. Computer-assisted navigation system have already improved the precision of drilling procedures performed for various indications. Basically, however, a navigation is only as accurate as the underlying imaging. The use of preoperative data sets assumes an invasive and/or elaborate intraoperative recording procedure. For a procedure not requiring recording to be possible, image diffusion of the MRI and ISO-C(3D) data sets during the surgery would be necessary. In the present case a preoperative MRI data set was first combined with the ISO-C(3D) data set acquired intraoperatively. To this end, following application of the reference base a 3D scan was performed, and the data ascertained were transferred to the navigation system and in addition to the planning software. After fusion of the images the drilling canals were planned and implemented on the basis of the additional information emerging from the combination of the data. To be sure of success postoperatively, this was also merged with the preoperative MRI. The example shows that combining data sets makes it possible to improve the precision and safety of drilling in target areas that cannot be adequately imaged. In future, we hope it will prove possible to transfer the image data back into the navigation system after they have been merged. At present this is only possible with CT and MRI images. A comparative clinical trial is needed to find to what extent the success rate is improved over that achieved with conventional techniques.
引用
收藏
页码:344 / 349
页数:6
相关论文
共 50 条
  • [21] Development of a 3D LADAR system for autonomous navigation
    Ng, TC
    Guzmán, JI
    Tan, JC
    2004 IEEE CONFERENCE ON ROBOTICS, AUTOMATION AND MECHATRONICS, VOLS 1 AND 2, 2004, : 792 - 797
  • [22] Comparing the usefulness of a fluoroscopic navigation system in femoral trochanteric fracture for orthopaedic residents with the conventional method
    Takai, Hirokazu
    Mizuta, Kazutaka
    Murayama, Masatoshi
    Nakayama, Daisuke
    Kii, Sakumo
    Hayai, Chihiro
    Takahashi, Tomoki
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2020, 51 (08): : 1840 - 1845
  • [23] Intra-operative visualisation of 3D temperature maps and 3D navigation during tissue cryoablation
    Samset, E
    Mala, T
    Aurdal, L
    Balasingham, I
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2005, 29 (06) : 499 - 505
  • [24] Fluoroscopic navigation versus conventional manual positioning of the femoral component for hip resurfacing:: first experimental trial
    Gravius, Sascha
    Belei, Peter
    de la Fuente, Matias
    Mueller-Rath, Ralf
    Radermacher, Klaus
    Wirtz, Dieter Christian
    Mumme, Torsten
    BIOMEDIZINISCHE TECHNIK, 2008, 53 (04): : 204 - 212
  • [25] A New Navigation Method for 3D Virtual Environment Exploration
    Haydar, Mahmoud
    Maidi, Madjid
    Roussel, David
    Mallem, Malik
    INTELLIGENT SYSTEMS AND AUTOMATION, 2009, 1107 : 190 - 195
  • [26] Egocentric Navigation for Video Surveillance in 3D Virtual Environments
    de Haan, Gerwin
    Scheuer, Josef
    de Vries, Raymond
    Post, Frits H.
    3DUI : IEEE SYMPOSIUM ON 3D USER INTERFACES 2009, PROCEEDINGS, 2009, : 103 - +
  • [27] 3D ultrasound navigation in syrinx surgery - a feasibility study
    Bonsanto, MM
    Metzner, R
    Aschoff, A
    Tronnier, V
    Kunze, S
    Wirtz, CR
    ACTA NEUROCHIRURGICA, 2005, 147 (05) : 533 - 541
  • [28] Evaluation of 2D and 3D navigation for iliosacral screw fixation
    Behrendt, Daniel
    Muetze, Maria
    Steinke, Hanno
    Koestler, Martin
    Josten, Christoph
    Boehme, Jorg
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2012, 7 (02) : 249 - 255
  • [29] Evaluation of 2D and 3D navigation for iliosacral screw fixation
    Daniel Behrendt
    Maria Mütze
    Hanno Steinke
    Martin Koestler
    Christoph Josten
    Jörg Böhme
    International Journal of Computer Assisted Radiology and Surgery, 2012, 7 : 249 - 255
  • [30] 3D Audio Navigation - Feasibility and Requirements for Older Adults
    Mattheiss, Elke
    Regal, Georg
    Vogelauer, Christian
    Furtado, Hugo
    COMPUTERS HELPING PEOPLE WITH SPECIAL NEEDS, ICCHP 2020, PT II, 2020, 12377 : 323 - 331