Surface plasmon resonance based immunosensor for the detection of the cancer biomarker carcinoembryonic antigen

被引:125
|
作者
Altintas, Zeynep [1 ,2 ]
Uludag, Yildiz [1 ]
Gurbuz, Yasar [2 ]
Tothill, Ibtisam E. [1 ]
机构
[1] Cranfield Univ, Cranfield MK43 0AL, Beds, England
[2] Sabanci Univ, Fac Engn & Nat Sci, TR-34956 Istanbul, Turkey
关键词
Carcinoembryonic antigen; Immunoassay; SPR; Early diagnosis of cancer; Homogeneous assay; BIOSENSORS; MARKERS;
D O I
10.1016/j.talanta.2011.09.031
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An immunoassay in optimised conditions with a highly sensitive surface plasmon resonance (SPR) based biosensor was developed for the detection of the cancer biomarker carcinoembryonic antigen (CEA). Different formats of the immunoassay were initially investigated on the surface of the gold sensor chip. A self-assembled monolayer (SAM) was formed on the gold chip using 11-mercaptoundecanoic acid (MUDA), before the immobilisation of the antibodies was conducted. The assay was then formed in a direct capture and a sandwich assay. In order to increase the sensor signal the CEA antigen was incubated with the detection/capture antibody before it was injected to the sensor chip surface and the results were recorded in real-time using the Biacore 3000 instrument. A detection limit of 3 ng ml(-1) CEA was obtained with a dynamic detection range from 3 ng ml(-1) to 400 ng ml(-1) with correlation coefficients of 1.00 and 0.99 for the sandwich and rabbit anti-mouse (RAM) capture assay. Kinetic data analysis was performed for the standard capture test and subsequently for the developed assays and R-max showed an increase from 215 RU for the standard capture test to 428 RU for the RAM-capture assay and 734 RU for the sandwich assay, respectively. The developed SPR immunosensor using the sandwich assay format showed high sensitivity and reproducibility for CEA detection which makes it a promising procedure for cancer biomarker analysis. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:377 / 383
页数:7
相关论文
共 50 条
  • [41] Enhanced performance of a surface plasmon resonance-based immunosensor for the detection of glycocholic acid
    He, Qiyi
    Fang, Yanxiong
    Yang, Huiyi
    Shen, Ding
    Chen, Yingshan
    Zhong, Yingying
    Li, Xiangguang
    Eremin, Sergei A.
    Cui, Xiping
    Zhao, Suqing
    ANALYTICAL METHODS, 2021, 13 (16) : 1919 - 1924
  • [42] Photoelectrochemical immunosensor for carcinoembryonic antigen detection-an attempt for early cancer screening
    Mao, Chunling
    Wu, Lei
    Wen, Yi
    Tang, Ximing
    Huang, Zheng
    Zhao, Longshan
    BIOSENSORS & BIOELECTRONICS, 2023, 220
  • [43] Highly sensitive carboxyl-graphene oxide-based surface plasmon resonance immunosensor for the detection of lung cancer for cytokeratin 19 biomarker in human plasma
    Chiu, Nan-Fu
    Lin, Ting-Li
    Kuo, Chia-Tzu
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 265 : 264 - 272
  • [44] An optical immunosensor based on surface plasmon resonance for determination of bFGF
    Song, DQ
    Mu, Y
    Liu, X
    Zhao, LW
    Zhang, HQ
    Jin, QH
    MICROCHEMICAL JOURNAL, 2003, 74 (01) : 93 - 97
  • [45] Development and characterization of surface plasmon resonance (SPR)-based immunosensor
    Ichikawa, S
    Toyama, S
    Ikariyama, Y
    NIPPON KAGAKU KAISHI, 1997, (05) : 318 - 322
  • [46] AN IMMUNOSENSOR FOR SYPHILIS SCREENING BASED ON SURFACE-PLASMON RESONANCE
    SEVERS, AH
    SCHASFOORT, RBM
    SALDEN, MHL
    BIOSENSORS & BIOELECTRONICS, 1993, 8 (3-4): : 185 - 189
  • [47] Surface plasmon resonance immunosensor using Au nanoparticle for detection of TNT
    Kawaguchi, Toshikazu
    Shankaran, Dhesingh Ravi
    Kim, Sook Jin
    Matsumoto, Kiyoshi
    Toko, Kiyoshi
    Miura, Norio
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 133 (02) : 467 - 472
  • [48] Direct detection of carcinoembryonic antigen autoantibodies in clinical human serum samples using a surface plasmon resonance sensor
    Ladd, Jon
    Lu, Hailing
    Taylor, Allen D.
    Goodell, Vivian
    Disis, Mary L.
    Jiang, Shaoyi
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2009, 70 (01) : 1 - 6
  • [49] Sensitive Detection of Glycyrrhizin and Evaluation of the Affinity Constants by a Surface Plasmon Resonance-based Immunosensor
    Takatoshi Sakai
    Katsura Shinahara
    Akira Torimaru
    Hiroyuki Tanaka
    Yukihiro Shoyama
    Kiyoshi Matsumoto
    Analytical Sciences, 2004, 20 : 279 - 283
  • [50] Novel KinExA-based immunosensor for real-time measurement of the breast cancer biomarker carcinoembryonic antigen in serum
    Darwish, Ibrahim
    Wani, Tanveer
    Zargar, Seema
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2016, 251