Influence of Clinical Parameters on the Primary Stability of a Tapered Dental Implant: A Retrospective Analysis

被引:5
作者
Blume, Oliver [1 ]
Wildenhof, Jan [2 ]
Otto, Sven [3 ]
Probst, Florian A. [4 ]
机构
[1] Private Practice Dres Back & Blume, Munich, Germany
[2] Private Clin Schloss Schellenstein, Olsberg, Germany
[3] Martin Luther Univ Halle Wittenberg, Univ Hosp Oral & Plast Maxillofacial Surg, Halle, Germany
[4] Ludwig Maximilians Univ LMU, Univ Hosp, Dept Oral & Maxillofacial Surg & Facial Plast, Munich, Germany
关键词
bone quality; primary stability; tapered dental implant; undersized drilling protocol; BONE QUALITY; INSERTION TORQUE; SURGICAL TECHNIQUE; SECONDARY STABILITY; OUTCOMES; DESIGN; SITES;
D O I
10.11607/jomi.8682
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this study was to investigate the influence of different clinical parameters on the primary stability of a variable thread tapered implant system with a focus on surgical undersizing protocols. Materials and Methods: This retrospective study evaluated patients who received NobelActive implants in a single institution. The relationship between the independent variables, bone quality, implant diameter, implant length, implantation time, region of the jaw, and surgical undersizing protocol, and the dependent variable, maximum insertion torque, was investigated. Statistical analysis was conducted using analysis of variance (ANOVA) and multiple linear regression. Results: A total of 1,292 implants placed in 574 fully or partially edentulous patients were evaluated. For the total sample size, without further differentiation between bone qualities, statistically significantly higher primary stability values were shown for an 8% to 9% undersized group (50.33 +/- 17.16 Ncm), compared with a 16% undersized group (41.88 +/- 17.63 Ncm), a 20% undersized group (33.65 +/- 15.78 Ncm), a 26% to 28% undersized group (34.53 +/- 15.49 Ncm), and a 35% to 44% undersized group (32.78 +/- 18.80 Ncm). No statistical differences were found for undersizing protocols in bone quality 4. Bone quality had the highest influence on primary stability (Welch-Test F(3, 65.57) = 119.48, P < .001, eta(2)= .20). Contrary to the other investigated independent variables, no statistically significant differences in primary stability were found for the different implantation times. Conclusion: Undersizing protocols exceeding 8% to 9% do not seem to enhance primary stability values. Further studies are needed to investigate the biologic consequences of undersizing, including the impact of implant design characteristics.
引用
收藏
页码:762 / 770
页数:9
相关论文
共 49 条
[1]   Biomechanical aspects of initial intraosseous stability and implant design:: a quantitative micro-morphometric analysis [J].
Akca, Kivanc ;
Chang, Ting-Ling ;
Tekdemir, Ibrahim ;
Fanuscu, Mete I. .
CLINICAL ORAL IMPLANTS RESEARCH, 2006, 17 (04) :465-472
[2]   Impact of local and systemic factors on the incidence of failures up to abutment connection with modified surface oral implants [J].
Alsaadi, Ghada ;
Quirynen, Marc ;
Michiles, Katleen ;
Teughels, Wim ;
Komarek, Arnost ;
van Steenberghe, Daniel .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2008, 35 (01) :51-57
[3]   A biomechanical assessment of the relation between the oral implant stability at insertion and subjective bone quality assessment [J].
Alsaadi, Ghada ;
Quirynen, Marc ;
Michiels, Katleen ;
Jacobs, Reinhilde ;
van Steenberghe, Daniel .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2007, 34 (04) :359-366
[4]   Stability of tapered and parallel-walled dental implants: A systematic review and meta-analysis [J].
Atieh, Momen A. ;
Alsabeeha, Nabeel ;
Duncan, Warwick J. .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2018, 20 (04) :634-645
[5]   Implant Compression Necrosis: Current Understanding and Case Report [J].
Bashutski, Jill D. ;
D'Silva, Nisha J. ;
Wang, Hom-Lay .
JOURNAL OF PERIODONTOLOGY, 2009, 80 (04) :700-704
[6]   Evaluation of the correlation between insertion torque and primary stability of dental implants using a block bone test [J].
Bayarchimeg, Dorjpalam ;
Namgoong, Hee ;
Kim, Byung Kook ;
Kim, Myung Duk ;
Kim, Sungtae ;
Kim, Tae-Il ;
Seol, Yang Jo ;
Lee, Yong Moo ;
Ku, Young ;
Rhyu, In-Chul ;
Lee, Eun Hee ;
Koo, Ki-Tae .
JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2013, 43 (01) :30-36
[7]   Correlation of insertion torques with bone mineral density from dental quantitative CT in the mandible [J].
Beer, A ;
Gahleitner, A ;
Holm, A ;
Tschabitscher, M ;
Homolka, P .
CLINICAL ORAL IMPLANTS RESEARCH, 2003, 14 (05) :616-620
[8]   Immediate Restoration of NobelActive Implants Placed Into Fresh Extraction Sites in the Anterior Maxilla [J].
Bell, Christopher ;
Bell, Robert E. .
JOURNAL OF ORAL IMPLANTOLOGY, 2014, 40 (04) :455-458
[9]  
Binon PP, 2000, INT J ORAL MAX IMPL, V15, P76
[10]   Are insertion torque and early osseointegration proportional? A histologic evaluation [J].
Campos, Felipe E. B. ;
Jimbo, Ryo ;
Bonfante, Estevam A. ;
Barbosa, Darceny Z. ;
Oliveira, Maiolino T. F. ;
Janal, Malvin N. ;
Coelho, Paulo G. .
CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (11) :1256-1260