Comparison of Efficacy and Tolerability of Hylan G-F 20 in Patients with and without Effusions at the Time of Initial Injection

被引:5
|
作者
Waddell, Bradford S. [1 ]
Waddell, W. Hunter [1 ]
Waddell, David D. [1 ]
机构
[1] Orthoped Specialists Louisiana, Dept Orthoped, Shreveport, LA 71101 USA
关键词
viscosupplementation; effusion; knee; KNEE OSTEOARTHRITIS; MULTICENTER TRIAL; VISCOSUPPLEMENTATION; G-F-20; HYALURONAN; SAFETY;
D O I
10.1055/s-0034-1376328
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
An effusion at the onset of viscosupplementation has been thought to diminish the efficacy and increase adverse event rates. This study compares efficacy of hylan G-F 20 in patients with and without an effusion. Patients with knee osteoarthritis (OA) received three weekly injections of hylan G-F 20. A total of 50 patients with an effusion requiring aspiration were compared with 50 matched patients without an effusion. Outcome measurements included Western Ontario and McMaster's Universities Osteoarthritis index (WOMAC) and visual analog scale (VAS). Patients were followed for 26 weeks. Both effusion and control group VAS was significantly lowered at all time points. WOMAC scores improved (p < 0.025) at all visits in the effusion group except for WOMAC A-1 week 14. Control WOMAC scores also significantly improved at all visits (p < 0.027), except for full WOMAC and WOMAC A-1 at week 1. Neither group experienced an adverse event. Presence of an effusion at onset of viscosupplementation requiring aspiration does not negatively impact efficacy of hylan G-F 20 or increase adverse event rates.
引用
收藏
页码:213 / 222
页数:10
相关论文
共 50 条
  • [1] Hylan G-F 20 Single-Injection Formulation
    Frampton, James E.
    DRUGS & AGING, 2010, 27 (01) : 77 - 85
  • [2] Viscosupplementation with hylan G-F 20 in patients with osteoarthrosis of the knee
    Bert, Jack M.
    Waddell, David D.
    THERAPEUTIC ADVANCES IN MUSCULOSKELETAL DISEASE, 2010, 3 (03) : 127 - 132
  • [3] A randomized, single-blind comparison of the efficacy and tolerability of hylan G-F 20 and triamcinolone hexacetonide in patients with osteoarthritis of the knee
    Caborn, D
    Rush, J
    Lanzer, W
    Parenti, D
    Murray, C
    JOURNAL OF RHEUMATOLOGY, 2004, 31 (02) : 333 - 343
  • [4] The role of elastoviscosity in the efficacy of viscosupplementation for osteoarthritis of the knee: A comparison of hylan G-F 20 and a lower-molecular-weight hyaluronan
    Wobig, M
    Bach, G
    Beks, P
    Dickhut, A
    Runzheimer, J
    Schwieger, G
    Vetter, G
    Balazs, E
    CLINICAL THERAPEUTICS, 1999, 21 (09) : 1549 - 1562
  • [5] Delayed Total Knee Replacement with Hylan G-F 20
    Waddell, David D.
    Joseph, Biji
    JOURNAL OF KNEE SURGERY, 2016, 29 (02) : 159 - 168
  • [6] The role of viscosupplementation in the ankle using hylan G-F 20
    Carpenter, Brian
    Motley, Travis
    JOURNAL OF FOOT & ANKLE SURGERY, 2008, 47 (05) : 377 - 384
  • [7] Hylan G-F 20: Review of its Safety and Efficacy in the Management of Joint Pain in Osteoarthritis
    Migliore, A.
    Giovannangeli, F.
    Granata, M.
    Lagana, B.
    CLINICAL MEDICINE INSIGHTS-ARTHRITIS AND MUSCULOSKELETAL DISORDERS, 2010, 3 : 55 - 68
  • [8] Tolerability and short-term effectiveness of hylan G-F 20 in 4253 patients with osteoarthritis of the knee in clinical practice
    Kemper, F
    Gebhardt, U
    Meng, T
    Murray, C
    CURRENT MEDICAL RESEARCH AND OPINION, 2005, 21 (08) : 1261 - 1269
  • [9] The evaluation of efficacy and tolerability of Hylan G-F 20 in bilateral thumb base osteoarthritis: 6 months follow-up
    Ayhan, F. Figen
    Ustun, Nilgun
    CLINICAL RHEUMATOLOGY, 2009, 28 (05) : 535 - 541
  • [10] Efficacy and safety of hylan G-F 20 injection in treatment of knee osteoarthritis in Chinese patients: results of a prospective, multicentre, longitudinal study
    Yan, C. H.
    Chan, W. L.
    Yuen, W. H.
    Yung, Patrick S. H.
    Ip, K. Y.
    Fan, Jason C. H.
    Chiu, K. Y.
    HONG KONG MEDICAL JOURNAL, 2015, 21 (04) : 327 - 332