Development and comparison of various rod-shaped mini-reference electrode compositions based on Ag/AgCl for potentiometric applications

被引:0
作者
Nigde, Mustafa [1 ]
Agir, Ismail [2 ]
Yildirim, Ridvan [1 ]
Isildak, Ibrahim [1 ]
机构
[1] Yildiz Tech Univ, Fac Chem & Met Engn, Dept Bioengn, TR-34220 Istanbul, Turkey
[2] Istanbul Medeniyet Univ, Fac Engn & Nat Sci, Dept Bioengn, TR-34720 Istanbul, Turkey
关键词
STATE REFERENCE ELECTRODES; POLYMER; CHIP; PH;
D O I
10.1039/d1an01754c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Several fundamentally similar, miniaturized solid-state reference electrode designs, and their fabrication and comparison are described in this article. All electrodes were based on Ag/AgCl as their reference element. The best electrode (a three-layer assembly with graphite oxide, epoxy, and hardener as the framework providers and with well-mixed micro-Ag particles in the bottom layer, AgCl in the middle layer, and fine KCl powder in the top layer) exhibited satisfactory short-term performance to replace a commercial reference electrode in many cases and was rigorously tested in terms of pH response, long-term leakage, and the effect of oxygen to better evaluate its characteristics. To assess the electrode's performance in medically important studies, cytotoxicity experiments and tests in artificial saliva were also conducted. All tests demonstrated that our best reference electrode was stable and had a long shelf life.
引用
收藏
页码:516 / 526
页数:11
相关论文
共 39 条
[1]   Internet of Things Implementation of Nitrate and Ammonium Sensors for Online Water Monitoring [J].
Agir, Ismail ;
Yildirim, Ridvan ;
Nigde, Mustafa ;
Isildak, Ibrahim .
ANALYTICAL SCIENCES, 2021, 37 (07) :971-976
[2]  
[Anonymous], 2013, Handbook of Reference Electrodes, DOI DOI 10.1007/978-3-642-36188-3
[3]   Large-scale fabrication of flexible solid-state reference electrodes [J].
Bananezhad, Asma ;
Jovic, Milica ;
Villalobos, Luis Francisco ;
Agrawal, Kumar Varoon ;
Ganjali, Mohammad Reza ;
Girault, Hubert H. .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2019, 847
[4]   Junction-less reference electrode for potentiometric measurements obtained by buffering pH in a conducting polymer matrix [J].
Blaz, T ;
Migdalski, J ;
Lewenstam, A .
ANALYST, 2005, 130 (05) :637-643
[5]   Reference Electrodes for Electrochemical Sensors Based on Redox Couples Immobilized within Nafion Films [J].
Chen, Lifu ;
Compton, Richard G. .
ACS SENSORS, 2019, 4 (06) :1716-1723
[6]   Reference Electrodes Based on Ionic Liquid-Doped Reference Membranes with Biocompatible Silicone Matrixes [J].
Chen, Xin, V ;
Stein, Andreas ;
Buhlmann, Philippe .
ACS SENSORS, 2020, 5 (06) :1717-1725
[7]   Alternative strategy for manufacturing of all-solid-state reference electrodes for potentiometry [J].
Fernandes, J. C. B. ;
Heinke, E. V. .
JOURNAL OF SENSORS AND SENSOR SYSTEMS, 2015, 4 (01) :53-61
[8]   Electrochemical Biosensors as Potential Diagnostic Devices for Autoimmune Diseases [J].
Florea, Anca ;
Melinte, Gheorghe ;
Simon, Ioan ;
Cristea, Cecilia .
BIOSENSORS-BASEL, 2019, 9 (01)
[9]   Analytical quality solid-state composite reference electrode manufactured by injection moulding [J].
Granholm, Kim ;
Mousavi, Zekra ;
Sokalski, Tomasz ;
Lewenstam, Andrzej .
JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2014, 18 (03) :607-612
[10]   A reference electrode based on polyvinyl butyral (PVB) polymer for decentralized chemical measurements [J].
Guinovart, Tomas ;
Crespo, Gaston A. ;
Xavier Rius, F. ;
Andrade, Francisco J. .
ANALYTICA CHIMICA ACTA, 2014, 821 :72-80