T2 and T2* quantification using optimal B1 image reconstruction for multicoil arrays

被引:10
|
作者
Graves, Martin J. [1 ,2 ]
Emmens, Daniel [2 ]
Lejay, Hubert [3 ]
Hariharan, Hari [4 ]
Polzin, Jason [4 ]
Lomas, David J. [1 ]
机构
[1] Univ Cambridge Hosp, NHS Fdn Trust, Dept Radiol, Cambridge, England
[2] Univ Cambridge Hosp, NHS Fdn Trust, Dept Med Phys & Clin Engn, Cambridge, England
[3] GE Healthcare Diagnost Imaging, Buc, France
[4] GE Healthcare Diagnost Imaging, Waukesha, WI USA
关键词
T-2 relaxation time; T-2* relaxation time; optimal B-i reconstruction; articular cartilage; liver;
D O I
10.1002/jmri.21420
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the accuracy of low signal-to-noise ratio (SNR) T-2 and T-2* measurements using array coils and optimal B-1 image reconstruction (OBR) compared to the standard root sum of squares (RSS) reconstruction. Materials and Methods: Calibrated gels were used for the in vitro study of T-2. T-2 and T-2* measurements were obtained from a volunteer's knee and liver, respectively. T-2 and T-2* measurements were performed using multiecho spin echo and multiecho gradient echo sequences, respectively. SNR was deliberately kept low. The same raw data were used for both reconstructions. For the in vivo studies the effect of signal averaging was also investigated. Results: The optimal reconstructions demonstrated a lower mean background noise level than RSS. In vitro, the T-2 measurements made with OBR images agreed better with a reference high SNR measurement than measurements made from RSS images; the RSS image results overestimated the T2. In vivo, increasing the signal averages decreased the difference between the measurements obtained using the OBR and RSS methods, with RSS resulting in longer relaxation times. Conclusion: This work demonstrates improvements to the accuracy of T-2 and T-2* measurements obtained when OBR is used compared to RSS, particularly in the case of low SNR.
引用
收藏
页码:278 / 281
页数:4
相关论文
共 50 条
  • [1] Simultaneous T1, T2 and T2*mapping of the liver with multi-shot MI-SAGE
    Zhang, Ke
    Triphan, Simon M. F.
    Wielpuetz, Mark O.
    Ziener, Christian H.
    Ladd, Mark E.
    Schlemmer, Heinz-Peter
    Kauczor, Hans-Ulrich
    Kurz, Felix T.
    Sedlaczek, Oliver
    MAGNETIC RESONANCE IMAGING, 2024, 105 : 75 - 81
  • [2] Feasibility study for evaluating early lumbar facet joint degeneration using axial T1, T2, and T2*mapping in cartilage
    Hu, Jianzhong
    Zhang, Yi
    Duan, Chunyue
    Peng, Xianjing
    Hu, Ping
    Lu, Hongbin
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 46 (02) : 468 - 475
  • [3] Application of quantitative T1, T2 and T2*mapping magnetic resonance imaging in cartilage degeneration of the shoulder joint
    Cao, Guijuan
    Gao, Shubo
    Xiong, Bin
    SCIENTIFIC REPORTS, 2023, 13 (01):
  • [4] Simultaneous acquisition of T1ρ and T2 quantification in knee cartilage: Repeatability and diurnal variation
    Li, Xiaojuan
    Wyatt, Cory
    Rivoire, Julien
    Han, Eric
    Chen, Weitian
    Schooler, Joseph
    Liang, Fei
    Shet, Keerthi
    Souza, Richard
    Majumdar, Sharmila
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (05) : 1287 - 1293
  • [5] Assessment of early cartilage degeneration after slipped capital femoral epiphysis using T2 and T2*mapping
    Miese, Falk Roland
    Zilkens, Christoph
    Holstein, Arne
    Bittersohl, Bernd
    Kroepil, Patric
    Mamisch, Tallal Charles
    Lanzman, Rotem Shlomo
    Bilk, Philip
    Blondin, Dirk
    Jaeger, Marcus
    Krauspe, Ruediger
    Fuerst, Guenther
    ACTA RADIOLOGICA, 2011, 52 (01) : 106 - 110
  • [6] Assessment of MRF for simultaneous T1 and T2 quantification and water–fat separation in the liver at 0.55 T
    Yuchi Liu
    Jesse Hamilton
    Yun Jiang
    Nicole Seiberlich
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2023, 36 : 513 - 523
  • [7] Validation of T2*in-line analysis for tissue iron quantification at 1.5 T
    Alam, Mohammed H.
    He, Taigang
    Auger, Dominique
    Smith, Gillian C.
    Drivas, Peter
    Wage, Rick
    Izgi, Cemil
    Symmonds, Karen
    Greiser, Andreas
    Spottiswoode, Bruce S.
    Anderson, Lisa
    Firmin, David
    Pennell, Dudley J.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2016, 18
  • [8] Validation of T2* in-line analysis for tissue iron quantification at 1.5 T
    Mohammed H. Alam
    Taigang He
    Dominique Auger
    Gillian C. Smith
    Peter Drivas
    Rick Wage
    Cemil Izgi
    Karen Symmonds
    Andreas Greiser
    Bruce S. Spottiswoode
    Lisa Anderson
    David Firmin
    Dudley J. Pennell
    Journal of Cardiovascular Magnetic Resonance, 18
  • [9] B1 Field inhomogeneity correction for qDESS T2 mapping: application to rapid bilateral knee imaging
    Barbieri, Marco
    Watkins, Lauren E.
    Mazzoli, Valentina
    Desai, Arjun D.
    Rubin, Elka
    Schmidt, Andrew
    Gold, Garry Evan
    Hargreaves, Brian Andrew
    Chaudhari, Akshay Sanjay
    Kogan, Feliks
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2023, 36 (05): : 711 - 724
  • [10] Quantitative Analysis of Supraspinatus Tendon Pathologies via T2/T2* Mapping Techniques with 1.5 T MRI
    Ece, Bunyamin
    Yigit, Hasan
    Ergun, Elif
    Koseoglu, Enver Necip
    Karavas, Erdal
    Aydin, Sonay
    Kosar, Pinar Nercis
    DIAGNOSTICS, 2023, 13 (15)