Dual biomineralized metal-organic frameworks-mediated conversion of chemical energy to electricity enabling portable PEC sensing of telomerase activity in bladder cancer tissues
被引:28
作者:
Li, Fenglan
[1
]
Xu, Mingdi
[2
]
Zhuang, Junyang
[1
]
机构:
[1] Fujian Med Univ, Higher Educ Key Lab Nano Biomed Technol Fujian Pr, Sch Pharm, Fuzhou 350122, Peoples R China
[2] Fujian Univ Technol, Coll Ecol Environm & Urban Construct, Fuzhou 350108, Peoples R China
基金:
中国国家自然科学基金;
关键词:
Photoelectrochemical assay;
Biomineralized ZIF-8;
Telomerase activity;
Y-junction DNA;
Metal-organic framework;
DNA;
BIOSENSOR;
ASSAY;
D O I:
10.1016/j.bios.2022.114070
中图分类号:
Q6 [生物物理学];
学科分类号:
071011 ;
摘要:
In this work, we report on a portable photoelectrochemical (PEC) sensing system for telomerase activity detection based on dual biomineralized ZIF-8 nanoparticles (NPs)-medicated conversion of chemical energy to electricity and terminal deoxynucleoside transferase (TdTase)-catalyzed elongation of Y-junction DNA structure. Two kinds of biomineralized ZIF-8 NPs including glucose oxidase (GOx)-encapsulated ZIF-8 (GZIF) and horse-radish peroxidase (HRP)-encapsulated ZIF-8 (HZIF) are involved in this assay system. The recognition of telomerase is started with telomerase-catalyzed elongation of a telomerase substrate (TS) primer, which generates a longer elongation chain to trigger the formation of a Y-junction DNA structure. The Y-junction DNA with abundant 3'-OH terminal and small steric hindrance facilitates the implement of TdTase-catalyzed elongation reaction, in which the branches of Y-junction DNA are elongated and endowed with biotin moiety to capture streptavidin-modified GZIF (SA-GZIF). The signal transduction is then achieved on a luminol/HZIF/CdS-based photoelectrode. Once the H2O2 produced from GZIF-catalyzed hydrolysis of glucose is introduced to the photoelectrode, chemiluminescence of HRP-luminol-H2O2-p-iodo-phenol (PIP) system confined in HZIF is activated to excite photocurrent of CdS NPs, which is then recorded by a portable digital multimeter (DMM). The developed PEC sensing system possesses a wide calibration range from 50 to 5000 HeLa cells and a low detection limit of 46 cells. Significantly, the sensing platform is successfully applied to evaluate the telomerase activity in resected bladder tumor tissues. This work not only provides a diagnostic tool for telomerase-related diseases but also open a new avenue for establishing PEC assay methods using metal-organic framework (MOF) NPs.
引用
收藏
页数:8
相关论文