Dual biomineralized metal-organic frameworks-mediated conversion of chemical energy to electricity enabling portable PEC sensing of telomerase activity in bladder cancer tissues

被引:28
作者
Li, Fenglan [1 ]
Xu, Mingdi [2 ]
Zhuang, Junyang [1 ]
机构
[1] Fujian Med Univ, Higher Educ Key Lab Nano Biomed Technol Fujian Pr, Sch Pharm, Fuzhou 350122, Peoples R China
[2] Fujian Univ Technol, Coll Ecol Environm & Urban Construct, Fuzhou 350108, Peoples R China
基金
中国国家自然科学基金;
关键词
Photoelectrochemical assay; Biomineralized ZIF-8; Telomerase activity; Y-junction DNA; Metal-organic framework; DNA; BIOSENSOR; ASSAY;
D O I
10.1016/j.bios.2022.114070
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In this work, we report on a portable photoelectrochemical (PEC) sensing system for telomerase activity detection based on dual biomineralized ZIF-8 nanoparticles (NPs)-medicated conversion of chemical energy to electricity and terminal deoxynucleoside transferase (TdTase)-catalyzed elongation of Y-junction DNA structure. Two kinds of biomineralized ZIF-8 NPs including glucose oxidase (GOx)-encapsulated ZIF-8 (GZIF) and horse-radish peroxidase (HRP)-encapsulated ZIF-8 (HZIF) are involved in this assay system. The recognition of telomerase is started with telomerase-catalyzed elongation of a telomerase substrate (TS) primer, which generates a longer elongation chain to trigger the formation of a Y-junction DNA structure. The Y-junction DNA with abundant 3'-OH terminal and small steric hindrance facilitates the implement of TdTase-catalyzed elongation reaction, in which the branches of Y-junction DNA are elongated and endowed with biotin moiety to capture streptavidin-modified GZIF (SA-GZIF). The signal transduction is then achieved on a luminol/HZIF/CdS-based photoelectrode. Once the H2O2 produced from GZIF-catalyzed hydrolysis of glucose is introduced to the photoelectrode, chemiluminescence of HRP-luminol-H2O2-p-iodo-phenol (PIP) system confined in HZIF is activated to excite photocurrent of CdS NPs, which is then recorded by a portable digital multimeter (DMM). The developed PEC sensing system possesses a wide calibration range from 50 to 5000 HeLa cells and a low detection limit of 46 cells. Significantly, the sensing platform is successfully applied to evaluate the telomerase activity in resected bladder tumor tissues. This work not only provides a diagnostic tool for telomerase-related diseases but also open a new avenue for establishing PEC assay methods using metal-organic framework (MOF) NPs.
引用
收藏
页数:8
相关论文
共 34 条
[31]   Flexible photoelectrochemical biosensor for ultrasensitive microRNA detection based on concatenated multiplex signal amplification [J].
Zhao, Yuecan ;
Xiang, Junzhu ;
Cheng, Hao ;
Liu, Xiaojuan ;
Li, Feng .
BIOSENSORS & BIOELECTRONICS, 2021, 194
[32]   One-Step High-Throughput Telomerase Activity Measurement of Cell Populations, Single Cells, and Single-Enzyme Complexes [J].
Zheng, Ke-wei ;
Liu, Chao ;
Meng, Qing ;
Hao, Yu-hua ;
Zheng, Jin-ping ;
Li, Wei ;
Tan, Zheng .
ACS OMEGA, 2020, 5 (38) :24666-24673
[33]   Ultra-sensitive and chemiluminescent detection of telomerase activity via handheld luminometer [J].
Zhu, Jinrui ;
Wang, Yan ;
Li, Baoxin ;
Jin, Yan .
SENSORS AND ACTUATORS B-CHEMICAL, 2019, 301
[34]   Targeted gene silencing in vivo by platelet membrane-coated metal-organic framework nanoparticles [J].
Zhuang, Jia ;
Gong, Hua ;
Zhou, Jiarong ;
Zhang, Qiangzhe ;
Gao, Weiwei ;
Fang, Ronnie H. ;
Zhang, Liangfang .
SCIENCE ADVANCES, 2020, 6 (13)