Seismic Vulnerability and performance level of confined brick walls

被引:0
|
作者
Ghalehnovi, M. [1 ]
Rahdar, H. A. [1 ]
机构
[1] Univ Sistan & Baluchestan, Zahedan, Iran
来源
2008 SEISMIC ENGINEERING CONFERENCE COMMEMORATING THE 1908 MESSINA AND REGGIO CALABRIA EARTHQUAKE, PTS 1 AND 2 | 2008年 / 1020卷
关键词
performance level; masonry structures; Seismic Vulnerability; accelerator suitable with geology conditions;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
There has been an increase on the interest of Engineers and designers to use designing methods based on displacement and behavior ( designing based on performance) Regarding to the importance of resisting structure design against dynamic loads such as earthquake, and inability to design according to prediction of nonlinear behavior element caused by nonlinear properties of constructional material. Economically speaking, easy carrying out and accessibility of masonry material have caused an enormous increase in masonry structures in villages, towns and cities. On the other hand, there is a necessity to study behavior and Seismic Vulnerability in these kinds of structures since Iran is located on the earthquake belt of Alpide. Different reasons such as environmental, economic, social, cultural and accessible constructional material have caused different kinds of constructional structures. In this study, some tied walls have been modeled with software and with relevant accelerator suitable with geology conditions under dynamic analysis to research on the Seismic Vulnerability and performance level of confined brick walls. Results from this analysis seem to be satisfactory after comparison of them with the values in Code ATC40, FEMA and standard 2800 of Iran.
引用
收藏
页码:1738 / 1746
页数:9
相关论文
共 50 条
  • [1] Study of the seismic performance of damaged confined brick masonry walls reinforced with FRCM
    Qu, Fenghao
    Yin, Shiping
    Wang, Fei
    Wang, Boxue
    MATERIALS AND STRUCTURES, 2024, 57 (09)
  • [2] Evaluation of the seismic performance of brick masonry walls
    Bosiljkov V.
    Page A.W.
    Bokan-Bosiljkov V.
    Žarnicá R.
    Structural Control and Health Monitoring, 2010, 17 (01) : 100 - 118
  • [3] Study on seismic performance of autoclaved brick walls
    Zhang, Jianmin
    Yin, Zexiang
    Modelling, Measurement and Control B, 2017, 86 (02): : 447 - 455
  • [4] Experimental research on the seismic behavior of confined shale brick masonry walls
    Wang, Zhenggang
    Xue, Guoya
    Gao, Benli
    Zhang, Jintao
    Dongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Southeast University (Natural Science Edition), 2003, 33 (05): : 638 - 642
  • [5] Evaluation of seismic performance of anchored brick veneer walls
    Memari, AM
    Hamid, AA
    PERFORMANCE OF EXTERIOR BUILDING WALLS, 2003, 1422 : 115 - 131
  • [6] Out-of-Plane Seismic Performance and Detailing of Brick Veneer Walls
    Reneckis, Dziugas
    LaFave, James M.
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2010, 136 (07): : 781 - 794
  • [7] EXPERIMENTAL STUDY ON SEISMIC PERFORMANCE OF BRICK WALLS REINFORCED BY SPRAYING POLYURETHANE
    Liu Y.
    Tian Y.
    Huang Q.-X.
    Zhang Y.-X.
    Gongcheng Lixue/Engineering Mechanics, 2024, 41 (04): : 174 - 183
  • [8] Seismic performance of composite walls made of reinforced concrete and brick masonry
    Liang, Jianguo
    Zhang, Wangxi
    Zheng, Yongqiang
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2003, 24 (03):
  • [9] Experimental Seismic Performance Evaluation of Unreinforced Brick Masonry Shear Walls
    Javed, Mohammed
    Magenes, Guido
    Alam, Bashir
    Khan, Akhtar Naeem
    Ali, Qaisar
    Syed, Ali M.
    EARTHQUAKE SPECTRA, 2015, 31 (01) : 215 - 246
  • [10] SEISMIC BEHAVIOR OF UNREINFORCED AND CONFINED BRICK MASONRY WALLS BEFORE AND AFTER FERROCEMENT OVERLAY RETROFITTING
    Ashraf, Mohammad
    Khan, Akhtar Naeem
    Naseer, Amjad
    Ali, Qaisar
    Alam, Bashir
    INTERNATIONAL JOURNAL OF ARCHITECTURAL HERITAGE, 2012, 6 (06) : 665 - 688