Non-enzymatic continuous glucose monitoring system

被引:1
|
作者
Moore, Sean [1 ]
You, Byoung Hee [1 ]
Kim, Namwon [2 ]
Park, Taehyun [3 ]
Song, In-Hyouk [1 ]
机构
[1] Texas State Univ San Marcos, Dept Engn Technol, San Marcos, TX 78666 USA
[2] Texas State Univ San Marcos, Ingram Sch Engn, San Marcos, TX 78666 USA
[3] Kyungnam Univ, Sch Mech Engn, Changwon Si, Gyeongsangnam D, South Korea
来源
MICRO & NANO LETTERS | 2018年 / 13卷 / 08期
关键词
biosensors; patient monitoring; biochemistry; electrochemical sensors; electrochemical electrodes; blood; biomedical electrodes; chemical sensors; biomedical measurement; bioelectric phenomena; glucose concentration; entire glucose range; continuous glucose monitoring method; nonenzymatic continuous glucose monitoring system; nonenzymatic glucose sensor; biosensor development; electric properties; fluids contents; electrode surface area; impedimetric response; real-time measurement; charge transfer resistance; frequency; 10; 0; kHz; resistance; 1038; kohm; 752; 688; ELECTRODE; NANOPARTICLES; SENSOR; GOLD; NANOCOMPOSITES; FABRICATION; SIO2;
D O I
10.1049/mnl.2017.0894
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
A prominent field of study in biosensor development is the study of electric properties which provide valuable insight into the fluids contents. In this research, a non-enzymatic glucose sensor is fabricated, characterised, and employed. The developed device determines the effects of electrode surface area on sensing efficacy, the effects of glucose concentration on impedimetric response, and a real-time measurement of glucose concentration. Deviations throughout the entire glucose range are detected as an inverse of the impedance in the cell due to the inverse relationship of glucose concentration and charge transfer resistance. The continuous monitoring of glucose is demonstrated by a rapid device response over two iterations of glucose concentration in ascending order: 50 mu M, 400 mu M, and 3.2 mM. At a sustained frequency of 10 kHz, the result shows a stable impedimetric response of 1038, 752, and 688 k, respectively. The validity of the device as a continuous glucose monitoring method is carried out by repeating the cycle and observing the response.
引用
收藏
页码:1079 / 1084
页数:6
相关论文
共 50 条
  • [1] Non-enzymatic continuous glucose monitoring system
    Moore S.
    You B.H.
    Kim N.
    Park T.
    Song I.-H.
    Song, In-Hyouk (in-hyouk.song@txstate.edu), 2018, John Wiley and Sons Inc (13): : 1079 - 1084
  • [2] Wearable, robust, non-enzymatic continuous glucose monitoring system and its in vivo investigation
    Yoon, Hyosang
    Xuan, Xing
    Jeong, Sungkwan
    Park, Jae Y.
    BIOSENSORS & BIOELECTRONICS, 2018, 117 : 267 - 275
  • [3] Flexible hydrogel non-enzymatic QCM sensor for continuous glucose monitoring
    Liu N.
    Xiang X.
    Sun M.
    Li P.
    Qin H.
    Liu H.
    Zhou Y.
    Wang L.
    Wu L.
    Zhu J.
    Biosensors and Bioelectronics: X, 2022, 10
  • [4] A wearable non-enzymatic sensor for continuous monitoring of glucose in human sweat
    Chen, Yuhua
    Sun, Yanghan
    Li, Yi
    Wen, Zhuo
    Peng, Xinyu
    He, Yuanke
    Hou, Yuanfang
    Fan, Jingchuan
    Zang, Guangchao
    Zhang, Yuchan
    TALANTA, 2024, 278
  • [5] Continuous glucose monitoring using wearable non-enzymatic sensors in a physiological environment
    Abbasnia Tehrani M.
    Ahmadi S.H.
    Alimohammadi S.
    Sasanpour P.
    Batvani N.
    Kazemi S.H.
    Kiani M.A.
    Biosensors and Bioelectronics: X, 2024, 18
  • [6] A sensitive non-enzymatic dual-conductive biosensor for continuous glucose monitoring
    Wang, Xiao
    Huo, Haoling
    Xu, Congjie
    Lin, Huaijun
    Wang, Qiwei
    Yang, Junjie
    Vogel, Florian
    Wang, Xiaoying
    Lin, Zhidan
    Cao, Lin
    Li, Wei
    Zhang, Peng
    ANALYTICA CHIMICA ACTA, 2023, 1279
  • [7] Review-In Vivo and In Vitro Microneedle Based Enzymatic and Non-Enzymatic Continuous Glucose Monitoring Biosensors
    Chinnadayyala, Somasekhar R.
    Park, Ki Deok
    Cho, Sungbo
    ECS JOURNAL OF SOLID STATE SCIENCE AND TECHNOLOGY, 2018, 7 (07) : Q3159 - Q3171
  • [8] A non-enzymatic nanoceria electrode for non-invasive glucose monitoring
    Jiang, Lei
    Xue, Qi
    Jiao, Chuanjie
    Liu, Hanyun
    Zhou, Yan
    Ma, Hongchao
    Yang, Qingli
    ANALYTICAL METHODS, 2018, 10 (18) : 2151 - 2159
  • [9] Long-term stabled non-enzymatic glucose sensor for continuously monitoring system applications
    Park, Dae-Joon
    Lee, Yi-Jae
    Park, Jae-Yeong
    Kim, Dae Heum
    2008 3RD IEEE INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS, VOLS 1-3, 2008, : 706 - +
  • [10] Non-Enzymatic Graphene-Based Biosensors for Continous Glucose Monitoring
    Sakr, Mahmoud A.
    Serry, Mohamed
    2015 IEEE SENSORS, 2015, : 938 - 941