Non-enzymatic continuous glucose monitoring system

被引:1
作者
Moore, Sean [1 ]
You, Byoung Hee [1 ]
Kim, Namwon [2 ]
Park, Taehyun [3 ]
Song, In-Hyouk [1 ]
机构
[1] Texas State Univ San Marcos, Dept Engn Technol, San Marcos, TX 78666 USA
[2] Texas State Univ San Marcos, Ingram Sch Engn, San Marcos, TX 78666 USA
[3] Kyungnam Univ, Sch Mech Engn, Changwon Si, Gyeongsangnam D, South Korea
来源
MICRO & NANO LETTERS | 2018年 / 13卷 / 08期
关键词
biosensors; patient monitoring; biochemistry; electrochemical sensors; electrochemical electrodes; blood; biomedical electrodes; chemical sensors; biomedical measurement; bioelectric phenomena; glucose concentration; entire glucose range; continuous glucose monitoring method; nonenzymatic continuous glucose monitoring system; nonenzymatic glucose sensor; biosensor development; electric properties; fluids contents; electrode surface area; impedimetric response; real-time measurement; charge transfer resistance; frequency; 10; 0; kHz; resistance; 1038; kohm; 752; 688; ELECTRODE; NANOPARTICLES; SENSOR; GOLD; NANOCOMPOSITES; FABRICATION; SIO2;
D O I
10.1049/mnl.2017.0894
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
A prominent field of study in biosensor development is the study of electric properties which provide valuable insight into the fluids contents. In this research, a non-enzymatic glucose sensor is fabricated, characterised, and employed. The developed device determines the effects of electrode surface area on sensing efficacy, the effects of glucose concentration on impedimetric response, and a real-time measurement of glucose concentration. Deviations throughout the entire glucose range are detected as an inverse of the impedance in the cell due to the inverse relationship of glucose concentration and charge transfer resistance. The continuous monitoring of glucose is demonstrated by a rapid device response over two iterations of glucose concentration in ascending order: 50 mu M, 400 mu M, and 3.2 mM. At a sustained frequency of 10 kHz, the result shows a stable impedimetric response of 1038, 752, and 688 k, respectively. The validity of the device as a continuous glucose monitoring method is carried out by repeating the cycle and observing the response.
引用
收藏
页码:1079 / 1084
页数:6
相关论文
共 24 条
[1]   Palladium nanoparticles deposit on multi-walled carbon nanotubes and their catalytic applications for electrooxidation of ethanol and glucose [J].
Cai, Zhi-xiong ;
Liu, Cong-cong ;
Wu, Geng-huang ;
Chen, Xiao-mei ;
Chen, Xi .
ELECTROCHIMICA ACTA, 2013, 112 :756-762
[2]   Mediated biosensors [J].
Chaubey, A ;
Malhotra, BD .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (6-7) :441-456
[3]   Current and Emerging Technology for Continuous Glucose Monitoring [J].
Chen, Cheng ;
Zhao, Xue-Ling ;
Li, Zhan-Hong ;
Zhu, Zhi-Gang ;
Qian, Shao-Hong ;
Flewitt, Andrew J. .
SENSORS, 2017, 17 (01)
[4]   Fast and continuous microorganism detection using aptamer-conjugated fluorescent nanoparticles on an optofluidic platform [J].
Chung, Jinyang ;
Kang, Joon Sang ;
Jurng, Jong Soo ;
Jung, Jae Hee ;
Kim, Byoung Chan .
BIOSENSORS & BIOELECTRONICS, 2015, 67 :303-308
[5]   ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY [J].
CLARK, LC ;
LYONS, C .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1962, 102 (01) :29-&
[6]   A reinforced composite structure composed of polydiacetylene assemblies deposited on polystyrene microspheres and its application to H5N1 virus detection [J].
Dong, Wenjie ;
Luo, Jing ;
He, Hongxuan ;
Jiang, Long .
INTERNATIONAL JOURNAL OF NANOMEDICINE, 2013, 8 :221-232
[7]   Electrochemistry of glucose at gold nanoparticles modified graphite/SrPdO3 electrode - Towards a novel non-enzymatic glucose sensor [J].
El-Ads, Ekram H. ;
Galal, Ahmed ;
Atta, Nada F. .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 749 :42-52
[8]   Silver nanoparticles decorated carboxylate functionalized SiO2, New nanocomposites for non-enzymatic detection of glucose and hydrogen peroxide [J].
Ensafi, Ali A. ;
Zandi-Atashbar, N. ;
Rezaei, B. ;
Ghiaci, M. ;
Taghizadeh, M. .
ELECTROCHIMICA ACTA, 2016, 214 :208-216
[9]   Fabrication and characterization of non-enzymatic glucose sensor based on ternary NiO/CuO/polyaniline nanocomposite [J].
Ghanbari, Kh. ;
Babaei, Z. .
ANALYTICAL BIOCHEMISTRY, 2016, 498 :37-46
[10]   Recent advances in lab-on-a-chip for biosensing applications [J].
Lafleur, Josiane P. ;
Joensson, Alexander ;
Senkbeil, Silja ;
Kutter, Joerg P. .
BIOSENSORS & BIOELECTRONICS, 2016, 76 :213-233