The performance of the Delphi Jadron Calorimeter at LEP

被引:1
作者
Ajinenko, I
Beloous, K
Chudoba, J
Czellar, S
Herr, H
Jouravlev, N
Khovansky, N
Kluit, P
Krumstein, Z
Kurvinen, K
Lapin, V
Leitner, R
Masik, J
Olchevski, A
Ridky, J
Sedykh, Y
Sicho, P
Smirnova, O
Solovianov, O
Tchikilev, O
Tkatchev, L
Tomsa, Z
Vrba, V
Williams, WS
Wetherell, AM
Zaslavsky, J
机构
[1] JOINT INST NUCL RES,DUBNA 101000,RUSSIA
[2] HELSINKI UNIV,SEFT,RES INST HIGH ENERGY PHYS,FIN-00014 HELSINKI,FINLAND
[3] UNIV OXFORD,DEPT PHYS,OXFORD OX1 3RH,ENGLAND
[4] ACAD SCI CZECH REPUBL,INST PHYS,DIV HIGH ENERGY PHYS,FZU,CS-18040 PRAGUE 8,CZECH REPUBLIC
[5] CHARLES UNIV,MFF NUCL CTR,CS-18000 PRAGUE 8,CZECH REPUBLIC
[6] NIKHEF H,1009 DB AMSTERDAM,NETHERLANDS
关键词
D O I
10.1109/23.507216
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The DELPHI Hadron Calorimeter was conceived more than ten years ago, as an instrument to measure the energy of hadrons and hadronic jets from e(+)e(-) collisions at the CERN collider LEP. In addition it was expected to provide a certain degree of discrimination between pions and muons. The detector is a rather simple and relatively inexpensive device consisting of around 20,000 limited streamer plastic tubes, with inductive pad read-out, embedded in the iron yoke of the 1.2 T DELPHI magnet. Its depth is at minimum 6.6 nuclear interaction lengths. The electronics necessary for the pad readout was designed to have an adequate performance for a reasonable cost. This detector has proved over six years of operation to have an entirely satisfactory performance and great reliability; for example less than 1% of the streamer tubes have failed and electronic problems remain at the per mil level. During the past two years an improvement programme has been under way. It has been found possible to use the streamer tubes as strips, hence giving better granularity and particle tracking, by reading out the cathode of individual tubes. The constraints on this were considerable because of the. inaccessibility of the detectors in the magnet yoke. However a cheap and feasible solution has been found. The cathode readout leads to an improved energy resolution, better mu identification, a better pi/mu separation and to possibilities of neutral particle separation. The simultaneous anode read-out of several planes of the endcaps of the detector will provide a fast trigger in the forward/backward direction which is an important improvement for LEP200. On the barrel the system will provide a cosmic trigger which is very useful for calibration as counting rates at LEP200 will be very low.
引用
收藏
页码:1751 / 1756
页数:6
相关论文
共 3 条
[1]   THE CATHODE READ-OUT OF THE DELPHI HADRON CALORIMETER [J].
AJINENKO, I ;
CHUDOBA, J ;
CZELLAR, S ;
FALALEEV, V ;
HERR, H ;
KHOVANSKY, N ;
KLUIT, P ;
KRUMSTEIN, Z ;
KURVINEN, K ;
LAPIN, I ;
LEITNER, R ;
MASIK, J ;
NIKOLAENKO, V ;
OLCHEVSKI, A ;
RIDKY, J ;
SEDYKH, Y ;
SICHO, P ;
SMIRNOVA, O ;
SOLOVIANOV, O ;
TCHIKILEV, O ;
TKATCHEV, L ;
TOMSA, Z ;
VRBA, V ;
WILLIAMS, WS ;
WETHERELL, AM ;
ZASLAVSKY, J .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) :485-490
[2]   PLASTIC STREAMER TUBES AND THEIR APPLICATIONS IN HIGH-ENERGY PHYSICS [J].
IAROCCI, E .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 217 (1-2) :30-42
[3]  
1991, NUCL INSTRUM METH A, V303, P233