Compensation of intrafractional motion for lung stereotactic body radiotherapy (SBRT) on helical TomoTherapy

被引:9
作者
Price, Alex [1 ]
Chen, Jiawei [2 ]
Chao, Edward [3 ]
Schnarr, Eric [3 ]
Schreiber, Eric [2 ]
Lu, Lan [2 ]
Cox, Andrea [3 ]
Chang, Sha [2 ]
Lian, Jun [2 ]
机构
[1] Washington Univ, Dept Radiat Oncol, St Louis, MO 63110 USA
[2] Univ N Carolina, Dept Radiat Oncol, Chapel Hill, NC 27599 USA
[3] Accuray Inc, 1310 Chesapeake Terrace, Sunnyvale, CA 94089 USA
关键词
TomoTherapy; intrafractional motion; jaw and MLC tracking; RESPIRATORY MOTION; MOVING TARGET; DELIVERY; MANAGEMENT; FEASIBILITY;
D O I
10.1088/2057-1976/ab059e
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Helical TomoTherapy has unique challenges in handling intrafractional motion compared to a conventional LINAC. In this study, we analyzed the impact of intrafractional motion on cumulative dosimetry using actual patient motion data from clinically treated patients and investigated real time jaw and multileaf collimator (MLC) compensation approaches to minimize the motion-induced dose discrepancy in clinically acceptable TomoTherapy lung SBRT treatments. Intrafractional motion traces from eight fiducial tracking CyberKnife lung tumor treatment cases were used in this study. These cases were re-planned on TomoTherapy for SBRT, with 18 Gy x 3 fractions to a planning target volume (PTV) defined on the breath-hold CT without ITV expansion. Each case was planned with four different jaw settings: 1 cm static, 2.5 cm static, 2.5 cm dynamic and 5 cm dynamic. In-house 4D dose accumulation software was used to compute the dose distributions with tumor motion and then compensate for that motion by modifying the original jaw and MLC positions to track the trajectory of the tumor. The impact of motion and effectiveness of compensation on the PTV coverage depends on the motion type and plan settings. On average, the PTVV100% (the percent volume of the PTV receiving the prescription dose) accumulated from three fractions changed from 96.6% (motion-free) to 83.1% (motion-included), 97.5% to 93.0%, 97.7% to 92.1%, and 98.1% to 93.7% for the 1 cm static jaw, 2.5 cm static jaw, 2.5 cm dynamic jaw and 5 cm dynamic jaw setting, respectively. When the jaw and MLC compensation algorithm was engaged, the PTV V 100% was restored back to 92.2%, 95.9%, 96.6% and 96.4%, for the four jaw settings mentioned above respectively. TomoTherapy lung tumor SBRT treatments using a field width of 2.5 cm or larger are less sensitive to motion than treatments using a 1 cm field width. For 1 cm field width plans, PTV coverage can be greatly compromised, even over three fractions. Once the motion pattern is known, the jaw and MLC compensation algorithm can largely minimize the loss of PTV coverage induced by the motion.
引用
收藏
页数:14
相关论文
共 26 条
[1]   Stereotactic body radiation therapy: The report of AAPM Task Group 101 [J].
Benedict, Stanley H. ;
Yenice, Kamil M. ;
Followill, David ;
Galvin, James M. ;
Hinson, William ;
Kavanagh, Brian ;
Keall, Paul ;
Lovelock, Michael ;
Meeks, Sanford ;
Papiez, Lech ;
Purdie, Thomas ;
Sadagopan, Ramaswamy ;
Schell, Michael C. ;
Salter, Bill ;
Schlesinger, David J. ;
Shiu, Almon S. ;
Solberg, Timothy ;
Song, Danny Y. ;
Stieber, Volker ;
Timmerman, Robert ;
Tome, Wolfgang A. ;
Verellen, Dirk ;
Wang, Lu ;
Yin, Fang-Fang .
MEDICAL PHYSICS, 2010, 37 (08) :4078-4101
[2]   Evaluation of TomoTherapy dose calculations with intrafractional motion and motion compensation [J].
Chao, Edward H. ;
Lucas, Daniel ;
Schnarr, Eric .
MEDICAL PHYSICS, 2018, 45 (01) :18-28
[3]   Dynamic tomotherapy delivery [J].
Chen, Yu ;
Chen, Quan ;
Chen, Mingli ;
Lu, Weiguo .
MEDICAL PHYSICS, 2011, 38 (06) :3013-3024
[4]   SBRT targets that move with respiration [J].
Dieterich, Sonja ;
Green, Olga ;
Booth, Jeremy .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 56 :19-24
[5]   Report of AAPM TG 135: Quality assurance for robotic radiosurgery [J].
Dieterich, Sonja ;
Cavedon, Carlo ;
Chuang, Cynthia F. ;
Cohen, Alan B. ;
Garrett, Jeffrey A. ;
Lee, Charles L. ;
Lowenstein, Jessica R. ;
d'Souza, Maximian F. ;
Taylor, David D., Jr. ;
Wu, Xiaodong ;
Yu, Cheng .
MEDICAL PHYSICS, 2011, 38 (06) :2914-2936
[6]   Accelerated tomotherapy delivery with TomoEdge technique [J].
Katayama, Sonja ;
Haefner, Matthias F. ;
Mohr, Angela ;
Schubert, Kai ;
Oetzel, Dieter ;
Debus, Juergen ;
Sterzing, Florian .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (02) :33-42
[7]   The management of respiratory motion in radiation oncology report of AAPM Task Group 76 [J].
Keall, Paul J. ;
Mageras, Gig S. ;
Balter, James M. ;
Emery, Richard S. ;
Forster, Kenneth M. ;
Jiang, Steve B. ;
Kapatoes, Jeffrey M. ;
Low, Daniel A. ;
Murphy, Martin J. ;
Murray, Brad R. ;
Ramsey, Chester R. ;
Van Herk, Marcel B. ;
Vedam, S. Sastry ;
Wong, John W. ;
Yorke, Ellen .
MEDICAL PHYSICS, 2006, 33 (10) :3874-3900
[8]   Investigation of dose homogeneity for loose helical tomotherapy delivery in the context of breath-hold radiation therapy [J].
Kim, B ;
Kron, T ;
Battista, J ;
Van Dyk, J .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (10) :2387-2404
[9]   Feasibility study of multi-pass respiratory-gated helical tomotherapy of a moving target via binary MLC closure [J].
Kim, Bryan ;
Chen, Jeff ;
Kron, Tomas ;
Battista, Jerry .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (22) :6673-6694
[10]   Interfraction Tumor Size Changes During Lung SBRT: What Factors Matter? [J].
King, K. ;
Mayekar, S. ;
Marwaha, G. ;
Tolekidis, G. ;
Cifter, G. ;
Zhen, H. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02) :E469-E470