Tautomer interconversion of 2,4-pentanedione during gas chromatography on an oxidized cyano-modified capillary column

被引:20
作者
Skrdla, PJ [1 ]
Antonucci, V [1 ]
Lindemann, C [1 ]
机构
[1] Merck & Co Inc, Rahway, NJ 07065 USA
关键词
D O I
10.1093/chromsci/39.10.431
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The tautomerization of 2,4-pentanedione (acetylacetone) is examined on a microbore column containing an acid-modified stationary phase made by oxidizing a commercially available cyano-modified column. This stationary phase is found to provide separation of the two tautomers, which allows the kinetic and thermodynamic properties of the on-column interconversion to be investigated. The enol-to-keto tautomerization is found to occur primarily in the stationary phase, being enthalpically driven. By treating the column as a reactor, the interconversion is investigated as a function of temperature. Monitoring the loss of the more gasstable 'enol' tautomer makes it possible to extract an energy of activation for the net tautomerization (42.7 kj/mol), because the reaction is found to obey pseudo first-order kinetics. Simple peak-shape analysis of the major component (enol), which is used commonly in treatments of peak tailing, provides insight into the nature of the retention processes of the two tautomers as well as information on chromatographic optimization.
引用
收藏
页码:431 / 440
页数:10
相关论文
共 26 条
[1]   CONFORMER INTERCONVERSION IN THE LC ANALYSIS OF TRIOSTIN-A AND ITS UNDER-N-METHYLATED SYNTHETIC ANALOG [J].
ALFREDSON, TV ;
BRUINS, PW ;
MAKI, AH ;
EXCOFFIER, JL .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1994, 32 (04) :132-138
[2]   DYNAMIC PHENOMENA DURING ENANTIOMER RESOLUTION BY COMPLEXATION GAS-CHROMATOGRAPHY - A KINETIC-STUDY OF ENANTIOMERIZATION [J].
BURKLE, W ;
KARFUNKEL, H ;
SCHURIG, V .
JOURNAL OF CHROMATOGRAPHY, 1984, 288 (01) :1-14
[3]   Oxidation studies of phenols with cobalt(II) ion-modified silica in a liquid chromatographic reactor [J].
Deng, ZQ ;
Dieckmann, GR ;
Langer, SH .
JOURNAL OF THE CHEMICAL SOCIETY-PERKIN TRANSACTIONS 2, 1998, (05) :1123-1128
[4]   EQUATIONS FOR CALCULATION OF CHROMATOGRAPHIC FIGURES OF MERIT FOR IDEAL AND SKEWED PEAKS [J].
FOLEY, JP ;
DORSEY, JG .
ANALYTICAL CHEMISTRY, 1983, 55 (04) :730-737
[5]   Peak tailing and mass transfer kinetics in linear chromatography [J].
Fornstedt, T ;
Zhong, GM ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 1996, 741 (01) :1-12
[6]   Peak tailing and slow mass transfer kinetics in nonlinear chromatography [J].
Fornstedt, T ;
Zhong, GM ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 1996, 742 (1-2) :55-68
[7]   STOCHASTIC CONSIDERATIONS ON CHROMATOGRAPHIC DISPERSION [J].
GIDDINGS, JC .
JOURNAL OF CHEMICAL PHYSICS, 1957, 26 (01) :169-173
[8]   Peak tailing and mass transfer kinetics in linear chromatography - Dependence on the column length and the linear velocity of the mobile phase [J].
Gotmar, G ;
Fornstedt, T ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 1999, 831 (01) :17-35
[9]   DETERMINATION OF ENANTIOMERIZATION BARRIERS BY COMPUTER-SIMULATION OF INTERCONVERSION PROFILES - ENANTIOMERIZATION OF DIAZIRIDINES DURING CHIRAL INCLUSION GAS-CHROMATOGRAPHY [J].
JUNG, M ;
SCHURIG, V .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1992, 114 (02) :529-534
[10]   Site selective processes: A combined theoretical and experimental investigation of thermally activated tautomerization processes in 2(2,4-dinitrobenzyl) pyridine derivatives [J].
Khatib, S ;
Tal, S ;
Godsi, O ;
Peskin, U ;
Eichen, Y .
TETRAHEDRON, 2000, 56 (36) :6753-6761