Fire performance of ultra-high performance concrete: effect of fine aggregate size and fibers

被引:11
作者
Zhang, Dong [1 ,2 ]
Tan, Kang Hai [2 ]
机构
[1] Fuzhou Univ, Coll Civil Engn, Fuzhou 350108, Peoples R China
[2] Nanyang Technol Univ, Sch Civil & Environm Engn, Singapore 639798, Singapore
基金
新加坡国家研究基金会;
关键词
Ultra-high performance concrete; Spalling; Fiber; Aggregate; High temperature; RESIDUAL MECHANICAL-PROPERTIES; REACTIVE POWDER CONCRETE; HIGH-STRENGTH CONCRETE; STEEL FIBERS; SPALLING RESISTANCE; HIGH-TEMPERATURE; TRANSPORT-PROPERTIES; TENSILE PROPERTIES; UHPC; MICROSTRUCTURE;
D O I
10.1007/s43452-022-00430-8
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study conducted a thorough investigation on the combined effects of fine aggregate (FA) size, steel fiber, and polypropylene (PP) fiber on the spalling behavior and mechanical properties of ultra-high-performance concrete (UHPC) at high temperature. FAs with 0.6, 2.36, and 4.75 mm were incorporated with steel fibers or PP fibers in UHPC. Test results showed that the synergistic enhancement in spalling prevention of UHPC at high temperature was only found in the combination of PP fiber and large-sized FA. Large-sized FA not only increased the fraction of microcracks but also enhanced their connectivity in UHPC with PP fibers, thus increasing the permeability and improving the spalling resistance at high temperature. This reduced the required PP fiber content for spalling prevention. Besides, steel fibers and large-sized FAs had a combined negative effect on mechanical properties above 600 degrees C, resulting in even lower mechanical properties at 900 degrees C compared to UHPC without any fiber and UHPC with PP fibers. Microstructural observation also found that the degradation of steel fibers and microcracks generated by expansion of aggregate both severely damaged the microstructures of UHPC at 900 degrees C. By contrast, adding PP fibers reduced compressive strength of UHPC below 600 degrees C due to the voids left by the decomposition of PP fibers, but it did not affect compressive strength at 900 degrees C, as the cracks in the matrix was enlarged, which reduced the negative effect of PP fibers.
引用
收藏
页数:14
相关论文
共 46 条
[1]   High temperature and residual properties of reactive powder concrete - A review [J].
Abid, Muhammad ;
Hou, Xiaomeng ;
Zheng, Wenzhong ;
Hussain, Raja Rizwan .
CONSTRUCTION AND BUILDING MATERIALS, 2017, 147 :339-351
[2]  
Abrmoff M.D., 2004, BIOPHOTONICS INT, V11, P36, DOI DOI 10.1201/9781420005615.AX4
[3]  
ASTM, 2020, STANDARD TEST METHOD, DOI [10.1520/D7136, DOI 10.1520/D7136]
[4]   The effect of high temperature on reactive powder concrete [J].
Canbaz, Mehmet .
CONSTRUCTION AND BUILDING MATERIALS, 2014, 70 :508-513
[5]   Evaluation of the mechanical properties of 200 MPa ultra-high-strength concrete at elevated temperatures and residual strength of column [J].
Choe, Gyeongcheol ;
Kim, Gyuyong ;
Gucunski, Nenad ;
Lee, Seonghun .
CONSTRUCTION AND BUILDING MATERIALS, 2015, 86 :159-168
[6]   Reactive powder based concretes: Mechanical properties, durability and hybrid use with OPC [J].
Cwirzen, A. ;
Penttala, V. ;
Vornanen, C. .
CEMENT AND CONCRETE RESEARCH, 2008, 38 (10) :1217-1226
[7]   Optimized design of steel fibres reinforced ultra-high performance concrete (UHPC) composites: Towards to dense structure and efficient fibre application [J].
Fan Dingqiang ;
Rui Yu ;
Liu Kangning ;
Tan Junhui ;
Shui Zhonghe ;
Wu Chunfeng ;
Wang Shuo ;
Guan Zhenfeng ;
Hu Zhengdong ;
Su Qiqi .
CONSTRUCTION AND BUILDING MATERIALS, 2021, 273
[8]   Workability, fiber distribution, and mechanical properties of UHPC with hooked end steel macro-fibers [J].
Hung, Chung-Chan ;
Chen, Yueh-Ting ;
Yen, Cheng-Hao .
CONSTRUCTION AND BUILDING MATERIALS, 2020, 260
[9]   Effect of aggregate on residual mechanical properties of heated ultra-high-strength concrete [J].
Kim, Young-Sun ;
Ohmiya, Yoshifumi ;
Kanematsu, Manabu ;
Kim, Gyu-Yong .
MATERIALS AND STRUCTURES, 2016, 49 (09) :3847-3859
[10]  
Klingsch E.W.H, 2014, EXPLOSIVE SPALLING C