Effect of Distal Radius Volar Plate Position on Contact Pressure Between the Flexor Pollicis Longus Tendon and the Distal Plate Edge

被引:57
作者
Tanaka, Yoshitaka [1 ,2 ]
Aoki, Mitsuhiro
Izumi, Tomoki
Fujimiya, Mineko
Yamashita, Toshihiko
Imai, Tomohito
机构
[1] Seikeikai Hosp, Dept Orthopaed Trauma, Sakai Ku, Sakai, Osaka 5900024, Japan
[2] Seikeikai Hosp, Microsurg Ctr, Sakai Ku, Sakai, Osaka 5900024, Japan
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 2011年 / 36A卷 / 11期
关键词
Flexor pollicis longus tendon; rupture; contact pressure; plate; radius fracture; INTERNAL-FIXATION; OPEN REDUCTION; SECONDARY LOSS; FRACTURES; OSTEOSYNTHESIS; SYSTEM;
D O I
10.1016/j.jhsa.2011.08.027
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Some clinical studies have suggested that distal radius plates placed distal to the watershed line have the potential to impinge on the traversing flexor tendons. However, the validity of this theory remains unclear. The purpose of this study was to evaluate the quantitative effect of volar plate position on flexor pollicis longus (FPL) tendon friction by measuring the contact pressure between the FPL tendon and the distal edge of the locking plate. Methods We used 7 fresh cadaveric upper extremities without wrist osteoarthritis or any deformity. External loads of 1.5 and 3.0 kgf were applied to the FPL tendon to simulate the pinch function of the thumb. A distal radius volar plate was applied to these cadaveric specimens in various positions relative to the watershed line. We measured contact pressure between the distal plate edge and the FPL tendon using a thin flexible pressure sensor and compared it among various positions of the volar plate for wrist extension angles of 00, 300, and 60 degrees and ulnar deviation angles of 0 degrees and 20 degrees. Results Under the 30 degrees or 60 degrees wrist extension condition, contact pressure significantly increased when the distal plate edge was placed distal to the watershed line, compared with when it was placed proximal to or at the watershed line. Conclusions Our quantitative results support the theory that plates placed distal to the watershed line have the potential to impinge on the traversing FPL tendon, even when a radius fracture heals anatomically. Clinical relevance This study clarifies a mechanism of FPL tendon irritation after volar plate fixation for distal radius fractures. (J Hand Surg 2011;36A:1790-1797. Copyright (C) 2011 by the American Society for Surgery of the Hand. All rights reserved.)
引用
收藏
页码:1790 / 1797
页数:8
相关论文
共 17 条
[1]  
Adham Mehdi N, 2009, Hand (N Y), V4, P406, DOI 10.1007/s11552-009-9180-0
[2]   Rupture of flexor pollicis longus tendon - A complication of volar plating of the distal radius [J].
Bell, JSP ;
Wollstein, R ;
Citron, ND .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (02) :225-226
[3]   Open reduction and internal fixation of unstable distal radius fractures with a low-profile plate: A multicenter study of 73 fractures [J].
Carter, PR ;
Frederick, HA ;
Laseter, GF .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1998, 23A (02) :300-307
[4]   FLEXOR POLLICIS LONGUS TENDON RUPTURES AFTER PALMAR PLATE FIXATION OF FRACTURES OF THE DISTAL RADIUS [J].
Casaletto, J. A. ;
Machin, D. ;
Leung, R. ;
Brown, D. J. .
JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2009, 34E (04) :471-474
[5]   Flexor tendon injuries following locked volar plating of distal radius fractures [J].
Cross, Andrew W. ;
Schmidt, Christopher C. .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2008, 33A (02) :164-167
[6]  
Douthit John D, 2005, Am J Orthop (Belle Mead NJ), V34, P140
[7]   Osteosynthesis of distal radial fractures with a volar locking screw plate system [J].
Drobetz, H ;
Kutscha-Lissberg, E .
INTERNATIONAL ORTHOPAEDICS, 2003, 27 (01) :1-6
[8]   Volar fixed-angle plating of distal radius extension fractures: influence of plate position on secondary loss of reduction - A biomechanic study in a cadaveric model [J].
Drobetz, H ;
Bryant, AL ;
Pokorny, T ;
Spitaler, R ;
Leixnering, M ;
Jupiter, JB .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (04) :615-622
[9]   Unstable Distal Radius Fractures in the Elderly Patient-Volar Fixed-Angle Plate Osteosynthesis Prevents Secondary Loss of Reduction [J].
Figl, Markus ;
Weninger, Patrick ;
Jurkowitsch, Josef ;
Hofbauer, Marcus ;
Schauer, Josef ;
Leixnering, Martin .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2010, 68 (04) :992-998
[10]   Open reduction and internal fixation of displaced intraarticular fractures of the distal radius - 31 patients followed for 3-7 years [J].
Hove, LM ;
Nilsen, PT ;
Furnes, O ;
Oulie, HE ;
Solheim, E ;
Molster, AO .
ACTA ORTHOPAEDICA SCANDINAVICA, 1997, 68 (01) :59-63