Development of prototype wireless transmission measurement for glucose in subcutaneous and brain striatum

被引:4
作者
Ahmad, Farook [1 ]
Chow, Fook Cheong [2 ]
Ho, Yah Wen [2 ]
Chin, Yew Siang [2 ]
Christenson, Andreas [3 ]
Bainbridge, Martina [4 ]
Yousof, Ahmad Pauzi Md [1 ]
Ab Ghani, Sulaiman [1 ]
机构
[1] Univ Sains Malaysia, USM, George Town 11800, Malaysia
[2] Copperlink Solut Sdn Bhd, Kuala Lumpur 59100, Malaysia
[3] Lund Univ, Dept Analyt Chem, S-22100 Lund, Sweden
[4] E Carolina Univ, Brody Sch Med, Dept Comparat Med, Greenville, SC USA
关键词
wireless transmission; insulin administration; glucose sensors; diabetes; hyperglycemia;
D O I
10.1002/elan.200704142
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Monitoring of glucose in subcutaneous and brain striatum have been extensively studied in the past. While biocompatibility was one of the limitations, others included the messy measuring equipments preclude monitoring in a complex environment. This study tried to establish an amperometric measurement of glucose in pre- and post-insulin-administration on diabetic and hyperglycemia rats via wireless. The results have indicated that the wireless sensing kit used was capable of monitoring glucose in both subcutaneous and brain. The physiological data have also shown a new insight on the fabrication of implantable glucose sensors.
引用
收藏
页码:1008 / 1015
页数:8
相关论文
共 22 条
[11]  
PALMER T, 1995, UNDERSTANDING ENZYME, P114
[12]   In vivo glucose monitoring: the clinical reality and the promise [J].
Pickup, JC ;
Hussain, F ;
Evans, ND ;
Sachedina, N .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (10) :1897-1902
[13]   Implantable closed-loop glucose-sensing and insulin delivery: the future for insulin pump therapy [J].
Renard, E .
CURRENT OPINION IN PHARMACOLOGY, 2002, 2 (06) :708-716
[14]  
ROARK J, 2003, HEALTHCARE INFORM TE
[15]   Closed-loop insulin delivery - the path to physiological glucose control [J].
Steil, GM ;
Panteleon, AE ;
Rebrin, K .
ADVANCED DRUG DELIVERY REVIEWS, 2004, 56 (02) :125-144
[16]   In vivo monitoring of dopamine overflow in the central nervous system by amperometric techniques combined with carbon fibre electrodes [J].
Suaud-Chagny, MF .
METHODS, 2004, 33 (04) :322-329
[17]   PARAVENTRICULAR NUCLEUS - A SITE FOR THE INTEGRATION OF NEUROENDOCRINE AND AUTONOMIC MECHANISMS [J].
SWANSON, LW ;
SAWCHENKO, PE .
NEUROENDOCRINOLOGY, 1980, 31 (06) :410-417
[18]   MOLECULAR PHYSIOLOGY OF GLUCOSE TRANSPORTERS [J].
THORENS, B ;
CHARRON, MJ ;
LODISH, HF .
DIABETES CARE, 1990, 13 (03) :209-218
[19]   A new amperometric glucose microsensor: in vitro and short-term in vivo evaluation [J].
Ward, WK ;
Jansen, LB ;
Anderson, E ;
Reach, G ;
Klein, JC ;
Wilson, GS .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (03) :181-189
[20]  
Weisman C. J., 2002, The Essential Guide to RF and Wireless