Fully Automated Dynamic In-Syringe Liquid-Phase Microextraction and On-Column Derivatization of Carbamate Pesticides with Gas Chromatography/Mass Spectrometric Analysis

被引:97
作者
Lee, Jingyi [1 ]
Lee, Hian Kee [1 ]
机构
[1] Natl Univ Singapore, Dept Chem, Singapore 117543, Singapore
关键词
ORTHOGONAL ARRAY DESIGN; HOLLOW-FIBER; WATER SAMPLES; CONVENTIONAL MICROSYRINGE; MICROWAVE DISSOLUTION; BIOLOGICAL SAMPLES; CHEMOMETRIC METHOD; MASS-SPECTROMETRY; SINGLE DROP; EXTRACTION;
D O I
10.1021/ac200807d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new fully automated dynamic in-syringe liquid-phase microextraction (LPME) and on-column derivatization approach, with gas chromatography/mass spectrometric (GC/MS) analysis, was developed to determine carbamate pesticides from water samples. With the use of a CTC CombiPal autosampler and its associated Cycle Composer software, a sample preparation-GC/MS method was enabled that allowed sample extraction, extract injection, and analyte derivatization to be carried out completely automatically. Optimization of extraction parameters was carried out by orthogonal array design which required a minimum of 16 experiments; the entire set of experiments was performed completely automatically and consecutively without any human intervention. Low limits of detection ranging from 0.05 to 0.1 mu g/L were achieved for the carbamates. Effective enrichment of the analytes at a low concentration of 0.01 mg/L was also achieved (enrichment factors of between 57 and 138). The precision of the optimized method was satisfactory, with relative standard deviations of <6.0% (n = 6). High relative recoveries of between 81 and 125% were obtained when the method was applied to the analysis of real water samples, indicating that the sample matrix had little effect on the developed method. This automated dynamic in-syringe LPME approach demonstrated the feasibility of a complete analytical system comprising sample preparation and GC/MS that might be operated onsite, fully automatically without human intervention.
引用
收藏
页码:6856 / 6861
页数:6
相关论文
共 27 条
[1]   ANALYSIS OF SULFUR-CONTAINING CARBAMATES BY FORMATION OF DERIVATIVES IN GAS-LIQUID CHROMATOGRAPH USING TRIMETHYLPHENYLAMMONIUM HYDROXIDE [J].
BROMILOW, RH ;
LORD, KA .
JOURNAL OF CHROMATOGRAPHY, 1976, 125 (03) :495-502
[2]   Behaviour of carbamate pesticides in gas chromatography and their determination with solid-phase extraction and solid-phase microextraction as preconcentration steps [J].
Carabias-Martínez, R ;
García-Hermida, U ;
Rodríguez-Gonzalo, E ;
Ruano-Miguel, L .
JOURNAL OF SEPARATION SCIENCE, 2005, 28 (16) :2130-2138
[3]   Development of a Henry's constant correlation and solubility measurements of n-pentane, i-pentane, cyclopentane, n-hexane, and toluene in water [J].
Chapoy, Antonin ;
Haghighi, Hooman ;
Tohidi, Bahman .
JOURNAL OF CHEMICAL THERMODYNAMICS, 2008, 40 (06) :1030-1037
[4]   Automated polyvinylidene difluoride hollow fiber liquid-phase microextraction of flunitrazepam in plasma and urine samples for gas chromatography/tandem mass spectrometry [J].
Cui, Shufen ;
Tan, Shuo ;
Ouyang, Gangfeng ;
Pawliszyn, Janusz .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (12) :2241-2247
[5]   Automated in-tube solid-phase microextraction-high-performance liquid chromatography for carbamate pesticide analysis [J].
Gou, YN ;
Eisert, R ;
Pawliszyn, J .
JOURNAL OF CHROMATOGRAPHY A, 2000, 873 (01) :137-147
[6]   Liquid phase microextraction in a single drop of organic solvent by using a conventional microsyringe [J].
He, Y ;
Lee, HK .
ANALYTICAL CHEMISTRY, 1997, 69 (22) :4634-4640
[7]   Application of static and dynamic liquid-phase microextraction in the determination of polycyclic aromatic hydrocarbons [J].
Hou, L ;
Lee, HK .
JOURNAL OF CHROMATOGRAPHY A, 2002, 976 (1-2) :377-385
[8]   Solvent microextraction into a single drop [J].
Jeannot, MA ;
Cantwell, FF .
ANALYTICAL CHEMISTRY, 1996, 68 (13) :2236-2240
[9]  
Kokosa J. M., 2007, US patent, Patent No. [7,178,414B1, 7178414]
[10]  
LAN WG, 1994, ANALYST, V119, P1669, DOI 10.1039/an9941901669