An innovative digital imaging set-up allowing a low-dose approach to phase contrast applications in the medical field

被引:189
作者
Olivo, A
Arfelli, F
Cantatore, G
Longo, R
Menk, RH
Pani, S
Prest, M
Poropat, P
Rigon, L
Tromba, G
Vallazza, E
Castelli, E
机构
[1] Univ Trieste, Dipartimento Fis, I-34100 Trieste, Italy
[2] Ist Nazl Fis Nucl, Sez Trieste, I-34100 Trieste, Italy
[3] Sincrotrone Trieste, I-34100 Trieste, Italy
关键词
phase contrast; diffraction; digital radiology; synchrotron radiation; image enhancement;
D O I
10.1118/1.1388219
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recently, new imaging modalities based on the detection of weak phase perturbations effects, among which are phase contrast and diffraction imaging, have been developed by several researchers. Due to their high sensitivity to weakly absorbing details, these techniques seem to be very promising for applications in the medical field. On the other hand, digital radiology is undergoing a wide diffusion, and its benefits are presently very well understood. Up to now, however, the strong pixel size constraints associated with phase contrast pattern detection limited the possibility of exploiting the advantages of phase contrast in digital radiology applications, In this paper, an innovative setup capable of removing the pixel size constraints, and thus opening the way to low dose digital phase contrast imaging, is described. Furthermore, we introduce an imaging technique based on the detection of radiation scattered at small angles: the information extracted from the sample is increased at no dose expense. We believe that several radiological fields, mammography being the first important example, may benefit from the herein described innovative imaging techniques. (C) 2001 American Association of Physicists in Medicine.
引用
收藏
页码:1610 / 1619
页数:10
相关论文
共 33 条
[1]   A linear array silicon pixel detector: images of a mammographic test object and evaluation of delivered doses [J].
Arfelli, F ;
Bonvicini, V ;
Bravin, A ;
Cantatore, G ;
Castelli, E ;
DallaPalma, L ;
DiMichiel, M ;
Longo, R ;
Olivo, A ;
Pani, S ;
Pontoni, D ;
Poropat, P ;
Prest, M ;
Rashevsky, A ;
Tromba, G ;
Vacchi, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (08) :1565-1573
[2]   Low-dose phase contrast x-ray medical imaging [J].
Arfelli, F ;
Assante, M ;
Bonvicini, V ;
Bravin, A ;
Cantatore, G ;
Castelli, E ;
Dalla Palma, L ;
Di Michiel, M ;
Longo, R ;
Olivo, A ;
Pani, S ;
Pontoni, D ;
Poropat, P ;
Prest, M ;
Rashevsky, A ;
Tromba, G ;
Vacchi, A ;
Vallazza, E ;
Zanconati, F .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (10) :2845-2852
[3]   DIGITAL MAMMOGRAPHY WITH SYNCHROTRON-RADIATION [J].
ARFELLI, F ;
BRAVIN, A ;
BARBIELLINI, G ;
CANTATORE, G ;
CASTELLI, E ;
DIMICHIEL, M ;
POROPAT, P ;
ROSEI, R ;
SESSA, M ;
VACCHI, A ;
DALLAPALMA, L ;
LONGO, R ;
BERNSTORFF, S ;
SAVOIA, A ;
TROMBA, G .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02) :1325-1328
[4]   Mammography of a phantom and breast tissue with synchrotron radiation and a linear-array silicon detector [J].
Arfelli, F ;
Bonvicini, V ;
Bravin, A ;
Cantatore, G ;
Castelli, E ;
Dalla Palma, L ;
Di Michiel, M ;
Longo, R ;
Olivo, A ;
Pani, S ;
Pontoni, D ;
Poropat, P ;
Prest, M ;
Rashevsky, A ;
Tromba, G ;
Vacchi, A .
RADIOLOGY, 1998, 208 (03) :709-715
[5]   Mammography with synchrotron radiation: Phase-detection techniques [J].
Arfelli, F ;
Bonvicini, V ;
Bravin, A ;
Cantatore, G ;
Castelli, E ;
Dalla Palma, L ;
Di Michiel, M ;
Fabrizioli, M ;
Longo, R ;
Menk, RH ;
Olivo, A ;
Pani, S ;
Pontoni, D ;
Poropat, P ;
Prest, M ;
Rashevsky, A ;
Ratti, M ;
Rigon, L ;
Tromba, G ;
Vacchi, A ;
Vallazza, E ;
Zanconati, F .
RADIOLOGY, 2000, 215 (01) :286-293
[6]   A multilayer edge-on silicon microstrip single photon counting detector for digital mammography [J].
Arfelli, F ;
Bonvicini, V ;
Bravin, A ;
Cantatore, G ;
Castelli, E ;
Fabrizioli, M ;
Longo, R ;
Olivo, A ;
Pani, S ;
Pontoni, D ;
Poropat, P ;
Prest, M ;
Rashevsky, A ;
Rigon, L ;
Tromba, G ;
Vacchi, A ;
Vallazza, E .
NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 1999, 78 :592-597
[7]  
Arfelli F, 1999, INFORM MIDEM, V29, P26
[8]  
ARFELLI F, 1993, PHYS MEDICA, V9, P229
[9]   SILICON X-RAY-DETECTOR - FOR SYNCHROTRON-RADIATION DIGITAL RADIOLOGY [J].
ARFELLI, F ;
BARBIELLINI, G ;
CANTATORE, G ;
CASTELLI, E ;
CRISTAUDO, P ;
DALLAPALMA, L ;
DIMICHIEL, M ;
LONGO, R ;
POROPAT, P ;
ROSEI, R ;
SESSA, M ;
TOMASINI, F ;
TROMBA, G ;
VACCHI, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 353 (1-3) :366-370
[10]   Silicon detectors for digital radiography [J].
Arfelli, F ;
Barbiellini, G ;
Bonvicini, V ;
Bravin, A ;
Cantatore, G ;
Castelli, E ;
dallaPalma, L ;
diMichiel, M ;
Longo, R ;
Olivo, A ;
Poropat, P ;
Prest, M ;
Rosei, R ;
Savoia, A ;
Sessa, M ;
Tomasini, F ;
Tromba, G ;
Vacchi, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 367 (1-3) :48-53