In-plane strength of concrete-filled steel tubular circular arches

被引:50
作者
Pi, Yong-Lin [2 ]
Liu, Changyong [1 ,2 ]
Bradford, Mark Andrew [2 ]
Zhang, Sumei [1 ]
机构
[1] Harbin Inst Technol, Sch Civil Engn, Harbin 150090, Peoples R China
[2] Univ New S Wales, Ctr Infrastruct Engn & Safety, Unsw Sydney, NSW 2052, Australia
基金
澳大利亚研究理事会;
关键词
Elastic-plastic buckling; Concrete-filled steel tubular arches; In-plane; Strength; Design equations; DESIGN; STABILITY; BEHAVIOR; COLUMNS;
D O I
10.1016/j.jcsr.2011.08.008
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
More than 400 concrete-filled steel tubular (CFST) arch bridges have been constructed worldwide so far. However, design codes or guidance for the in-plane strength design of CFST arches are yet to be developed. In current design practice, the philosophy for the in-plane strength design of reinforced and prestressed concrete arches is widely adopted for CFST arches. For this, the CFST arches are considered under central or eccentric axial compression and are treated similarly to CFST columns, and the classical buckling load of CFST columns is used as the reference elastic buckling load of CFST arches. However, under transverse loading, the in-plane elastic buckling behaviour of CFST arches, particularly shallow CFST arches, is very different from that of CFST columns under axial compression. In addition, different from CFST columns under central or eccentric axial compression, CFST arches are subjected to significant nonlinear bending actions and transverse deformations prior to buckling and these will influence the strength of CFST arches greatly. Therefore, it is doubtful if the current method for in-plane strength design of CFST arches can provide correct strength predictions. In this paper, a method for the in-plane strength design of CFST circular arches, which is consistent with the current major design codes for steel structures, is developed by considering both geometric and material nonlinearities. A design equation for the in-plane strength capacity of CFST arches under uniform compression, and a lower-bound design equation for the in-plane strength check of CFST arches under combined actions of bending and compression are proposed. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:77 / 94
页数:18
相关论文
共 43 条
[1]  
ABAQUS, 2008, STAND US MAN VERS 6
[2]  
[Anonymous], 2003, CODE DESIGN STEEL ST
[3]  
[Anonymous], 2005, Load and resistance factor design specification for structural steel buildings
[4]  
[Anonymous], STEEL TUBE CONFINED
[5]  
[Anonymous], 2002, J ZHEJIANG UNIV-SC A, DOI DOI 10.1007/BF03396433
[6]  
[Anonymous], 2002, CODE DESIGN CONCRETE
[7]   In-plane elastic stability of arches under a central concentrated load [J].
Bradford, MA ;
Uy, B ;
Pi, Y .
JOURNAL OF ENGINEERING MECHANICS-ASCE, 2002, 128 (07) :710-719
[8]  
Bradford MA, 1996, ACI STRUCT J, V93, P229
[9]  
*CEC, 1994, DES COMP STEEL CONCR
[10]   Push-out test of pre-stressing concrete filled circular steel tube columns by means of expansive cement [J].
Chang Xu ;
Huang Chengkui ;
Jiang Decheng ;
Song Yuancheng .
CONSTRUCTION AND BUILDING MATERIALS, 2009, 23 (01) :491-497