Percutaneous radiofrequency ablation of HCC: reduced ablation duration and increased ablation size using single, internally cooled electrodes with an optimized pulsing algorithm

被引:5
作者
Solbiati, Luigi [1 ,2 ]
Ierace, Tiziana [2 ]
Gennaro, Nicolo [3 ]
Muglia, Riccardo [3 ]
Cosman, Eric R., Jr. [4 ]
Goldberg, S. Nahum [5 ]
机构
[1] Humanitas Univ, Dept Biomed Sci, I-20090 Milan, Italy
[2] Humanitas Clin & Res Hosp, Dept Radiol, Milan, Italy
[3] Humanitas Univ, Training Sch Radiol, Milan, Italy
[4] Cambridge Intervent, Burlington, MA USA
[5] Hadassah Hebrew Univ, Dept Radiol, Med Ctr, Jerusalem, Israel
关键词
Thermal ablation; radiofrequency ablation; hepatocellular carcinoma; calibration; interventional oncology; SECONDARY LIVER-TUMORS; HEPATOCELLULAR-CARCINOMA; TISSUE ABLATION; MICROWAVE ABLATION; EX-VIVO; IN-VIVO; THERMAL ABLATION; METASTASES; MECHANISM;
D O I
10.1080/02656736.2020.1790678
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To assess the use of optimized radiofrequency (RF) to achieve larger, spherical ablation volumes with short application duration for hepatocellular carcinoma (HCC). Materials and methods: Twenty-two patients (M:F=17:5, median age 69.6year, range 63-88) with 28 HCCs due to HCV+liver cirrhosis underwent RFA. 20/28 (71.4%) were tumors <= 3cm diameter, and 8/28 (28.6%) ranged from 3.2 to 4.2cm. RF was applied using up to 2500mA via an optimized pulsing algorithm with real-time ultrasound monitoring to detect hyperechogenic changes. Single insertions of an internally cooled electrode were performed using exposed tips of 2 or 3cm for 13 HCCs and 4cm for 15 HCCs. All patients were followed-up for a minimum of 5years with contrast-enhanced computed tomography (CECT). Results: Technical success was achieved without adverse events in all cases. The mean ablation time was 8.52.6min. In 21/28 (75%), ablation duration ranged from 3 to 9min, with 12min duration applied in only 7/28 (25%). Mean coagulation diameters were 2.4 +/- 0.14, 3.3 +/- 0.62, and 4.4 +/- 1.0, for 2, 3 and 4cm electrodes, respectively (p < 0.01). The sphericity index was 74.9 +/- 12.8 for 4cm electrodes and 81.9 +/- 8.0 for shorter electrodes (p=0.091). At 5-year follow-up, no tumor <= 3cm had recurrence and only 2/8 (25%) > 3cm tumors developed local progression. One patient had multifocal disease with no local progression. Conclusion: Efficient delivery of RF energy can considerably decrease the ablation time in many instances while achieving larger, relatively spherical, and reproducible areas of ablation with extremely low rates of local tumor progression and adverse events.
引用
收藏
页码:861 / 867
页数:7
相关论文
共 48 条
[21]   Increased Ablation Zones Using a Cryo-Based Internally Cooled Bipolar RF Applicator in Ex Vivo Bovine Liver [J].
Rempp, Hansjoerg ;
Voigtlaender, Matthias ;
Clasen, Stephan ;
Kempf, Simone ;
Neugebauer, Alexander ;
Schraml, Christina ;
Schmidt, Diethard ;
Claussen, Claus D. ;
Enderle, Markus D. ;
Goldberg, S. Nahum ;
Pereira, Philippe L. .
INVESTIGATIVE RADIOLOGY, 2009, 44 (12) :763-768
[22]   Hepatocellular carcinoma: Percutaneous radiofrequency ablation using expandable needle electrodes and the double-insertion technique [J].
Shirato, K ;
Morimoto, M ;
Tomita, N ;
Kokawa, A ;
Sugimori, K ;
Saito, T ;
Tanaka, K .
HEPATO-GASTROENTEROLOGY, 2002, 49 (48) :1481-1483
[23]   No-Touch vs. Conventional Radiofrequency Ablation Using Twin Internally Cooled Wet Electrodes for Small Hepatocellular Carcinomas: A Randomized Prospective Comparative Study [J].
Suh, Yun Seok ;
Choi, Jae Won ;
Yoon, Jeong Hee ;
Lee, Dong Ho ;
Kim, Yoon Jun ;
Lee, Jeong Hoon ;
Yu, Su Jong ;
Cho, Eun Ju ;
Yoon, Jung Hwan ;
Lee, Jeong Min .
KOREAN JOURNAL OF RADIOLOGY, 2021, 22 (12) :1974-1984
[24]   Radiofrequency ablation in the liver using two cooled-wet electrodes in the bipolar mode [J].
Han, JK ;
Lee, JM ;
Kim, SH ;
Lee, JY ;
Park, HS ;
Eo, H ;
Choi, BI .
EUROPEAN RADIOLOGY, 2005, 15 (10) :2163-2170
[25]   Comparison of therapeutic efficacy and safety of radiofrequency ablation of hepatocellular carcinomas between internally cooled 15-G and 17-G single electrodes [J].
Park, H. J. ;
Lee, M. W. ;
Song, K. D. ;
Cha, D. I. ;
Rhim, H. ;
Kang, T. W. ;
Lim, S. ;
Lim, H. K. .
BRITISH JOURNAL OF RADIOLOGY, 2014, 87 (1036)
[26]   Radiofrequency ablation in the liver using two cooled-wet electrodes in the bipolar mode [J].
Joon Koo Han ;
Jeong Min Lee ;
Se Hyung Kim ;
Jae Young Lee ;
Hee Sun Park ;
Hong Eo ;
Byung Ihn Choi .
European Radiology, 2005, 15 :2163-2170
[27]   No-Touch Radiofrequency Ablation Using Twin Cooled Wet Electrodes for Recurrent Hepatocellular Carcinoma Following Locoregional Treatments [J].
Hong, Seong Jun ;
Kim, Jae Hyun ;
Yoon, Jeong Hee ;
Park, Jeong Hoan ;
Yoon, Jung-Hwan ;
Kim, Yoon Jun ;
Yu, Su Jong ;
Cho, Eun Ju ;
Lee, Jeong Min .
KOREAN JOURNAL OF RADIOLOGY, 2024, 25 (05) :438-448
[28]   Bipolar Radiofrequency ablation using internally cooled electrodes in ex vivo bovine liver -: Prediction of coagulation volume from applied energy [J].
Clasen, Stephan ;
Schmidt, Diethard ;
Dietz, Klaus ;
Boss, Andreas ;
Kroeber, Stefan M. ;
Schraml, Christina ;
Fritz, Jan ;
Claussen, Claus D. ;
Pereira, Philippe L. .
INVESTIGATIVE RADIOLOGY, 2007, 42 (01) :29-36
[29]   Intraoperative radiofrequency ablation using a loop internally cooled-perfusion electrode:: In vitro and in vivo experiments [J].
Lee, JM ;
Han, JK ;
Eoh, H ;
Kim, SH ;
Lee, JY ;
Lee, MW ;
Choi, BI .
JOURNAL OF SURGICAL RESEARCH, 2006, 131 (02) :215-224
[30]   Switching monopolar radiofrequency ablation technique using multiple, internally cooled electrodes and a multichannel generator - Ex vivo and in vivo pilot study [J].
Lee, Jeong Min ;
Han, Joon Koo ;
Kim, Hyo Cheol ;
Choi, Young Hun ;
Kim, Se Hyung ;
Choi, Jin Young ;
Choi, Byung Ihn .
INVESTIGATIVE RADIOLOGY, 2007, 42 (03) :163-171