Percutaneous radiofrequency ablation of HCC: reduced ablation duration and increased ablation size using single, internally cooled electrodes with an optimized pulsing algorithm

被引:5
|
作者
Solbiati, Luigi [1 ,2 ]
Ierace, Tiziana [2 ]
Gennaro, Nicolo [3 ]
Muglia, Riccardo [3 ]
Cosman, Eric R., Jr. [4 ]
Goldberg, S. Nahum [5 ]
机构
[1] Humanitas Univ, Dept Biomed Sci, I-20090 Milan, Italy
[2] Humanitas Clin & Res Hosp, Dept Radiol, Milan, Italy
[3] Humanitas Univ, Training Sch Radiol, Milan, Italy
[4] Cambridge Intervent, Burlington, MA USA
[5] Hadassah Hebrew Univ, Dept Radiol, Med Ctr, Jerusalem, Israel
关键词
Thermal ablation; radiofrequency ablation; hepatocellular carcinoma; calibration; interventional oncology; SECONDARY LIVER-TUMORS; HEPATOCELLULAR-CARCINOMA; TISSUE ABLATION; MICROWAVE ABLATION; EX-VIVO; IN-VIVO; THERMAL ABLATION; METASTASES; MECHANISM;
D O I
10.1080/02656736.2020.1790678
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To assess the use of optimized radiofrequency (RF) to achieve larger, spherical ablation volumes with short application duration for hepatocellular carcinoma (HCC). Materials and methods: Twenty-two patients (M:F=17:5, median age 69.6year, range 63-88) with 28 HCCs due to HCV+liver cirrhosis underwent RFA. 20/28 (71.4%) were tumors <= 3cm diameter, and 8/28 (28.6%) ranged from 3.2 to 4.2cm. RF was applied using up to 2500mA via an optimized pulsing algorithm with real-time ultrasound monitoring to detect hyperechogenic changes. Single insertions of an internally cooled electrode were performed using exposed tips of 2 or 3cm for 13 HCCs and 4cm for 15 HCCs. All patients were followed-up for a minimum of 5years with contrast-enhanced computed tomography (CECT). Results: Technical success was achieved without adverse events in all cases. The mean ablation time was 8.52.6min. In 21/28 (75%), ablation duration ranged from 3 to 9min, with 12min duration applied in only 7/28 (25%). Mean coagulation diameters were 2.4 +/- 0.14, 3.3 +/- 0.62, and 4.4 +/- 1.0, for 2, 3 and 4cm electrodes, respectively (p < 0.01). The sphericity index was 74.9 +/- 12.8 for 4cm electrodes and 81.9 +/- 8.0 for shorter electrodes (p=0.091). At 5-year follow-up, no tumor <= 3cm had recurrence and only 2/8 (25%) > 3cm tumors developed local progression. One patient had multifocal disease with no local progression. Conclusion: Efficient delivery of RF energy can considerably decrease the ablation time in many instances while achieving larger, relatively spherical, and reproducible areas of ablation with extremely low rates of local tumor progression and adverse events.
引用
收藏
页码:861 / 867
页数:7
相关论文
共 50 条
  • [1] Percutaneous Radiofrequency Ablation Using Internally Cooled Wet Electrodes for the Treatment of Hepatocellular Carcinoma
    Kim, Jin Hyoung
    Kim, Pyo Nyun
    Won, Hyung Jin
    Shin, Yong Moon
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (02) : 471 - 476
  • [2] Percutaneous radiofrequency ablation using internally cooled wet electrodes for the treatment of patients with lung tumors
    Iezzi, R.
    Larici, A. R.
    Posa, A.
    Carchesio, F.
    Congedo, M. T.
    Tagliaferri, L.
    Cassano, A.
    D'argento, E.
    Mantini, G.
    Rodolfino, E.
    Margaritora, S.
    Bria, E.
    Tortora, G.
    Valentini, V.
    Manfredi, R.
    EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2019, 23 (15) : 6554 - 6561
  • [3] Percutaneous radiofrequency ablation using internally cooled wet electrodes for treatment of colorectal liver metastases
    Yoon, H. M.
    Kim, J. H.
    Shin, Y. M.
    Won, H. J.
    Kim, P. N.
    CLINICAL RADIOLOGY, 2012, 67 (02) : 122 - 127
  • [4] Percutaneous Radiofrequency Ablation with Internally Cooled versus Internally Cooled Wet Electrodes for Small Subphrenic Hepatocellular Carcinomas
    Kim, Jin Hyoung
    Kim, Pyo Nyun
    Won, Hyung Jin
    Shin, Yong Moon
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2013, 24 (03) : 351 - 356
  • [5] Optimization and characterization of a novel internally-cooled radiofrequency ablation system with optimized pulsing algorithm in an ex-vivo bovine liver
    Ben-David, Eliel
    Nissenbaum, Isaac
    Gurevich, Svetlana
    Cosman, Eric R., Jr.
    Goldberg, S. Nahum
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2019, 36 (02) : 81 - 88
  • [6] Radiofrequency renal ablation: In vivo comparison of internally cooled, multitined expandable and internally cooled perfusion electrodes
    Lee, JM
    Han, JK
    Chang, JM
    Chung, SY
    Son, KR
    Kim, SH
    Lee, JY
    Choi, BI
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2006, 17 (03) : 549 - 556
  • [7] Comparison of Microwave Ablation and Multipolar Radiofrequency Ablation In Vivo Using Two Internally Cooled Probes
    Fan, WeiJun
    Li, Xin
    Zhang, Liang
    Jiang, Hua
    Zhang, JianLei
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (01) : W46 - W50
  • [8] CT findings after radiofrequency ablation in rabbit livers: Comparison of internally cooled electrodes, perfusion electrodes, and internally cooled perfusion electrodes
    Kim, Seung Kwon
    Gu, Myung Seo
    Hong, Hyun Pyo
    Choi, Dongil
    Chae, Seoung Wan
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2007, 18 (11) : 1417 - 1427
  • [9] Percutaneous Radiofrequency Ablation of Hepatocellular Carcinomas Adjacent to the Gallbladder with Internally Cooled Electrodes: Assessment of Safety and Therapeutic Efficacy
    Kim, Sang Won
    Rhim, Hyunchul
    Park, Mihyun
    Kim, Heejung
    Kim, Young-sun
    Choi, Dongil
    Lim, Hyo K.
    KOREAN JOURNAL OF RADIOLOGY, 2009, 10 (04) : 366 - 376
  • [10] Radiofrequency Ablation in the Treatment of Large Hepatic Hemangiomas A Comparison of Multitined and Internally Cooled Electrodes
    Gao, Jun
    Ding, Xuemei
    Ke, Shan
    Xin, Zonghai
    Ning, Chunmin
    Sha, Qi
    Sun, Wenbing
    JOURNAL OF CLINICAL GASTROENTEROLOGY, 2014, 48 (06) : 540 - 547