Supervisory Model Predictive Control of the Heat Integrated Distillation Column

被引:11
作者
Meyer, Kristian [1 ]
Bisgaard, Thomas [1 ]
Huusom, Jakob K. [1 ]
Abildskov, Jens [1 ]
机构
[1] Tech Univ Denmark, Dept Chem & Biochem Engn, Soltofts Plads Bldg 227, DK-2800 Lyngby, Denmark
来源
IFAC PAPERSONLINE | 2017年 / 50卷 / 01期
关键词
Control system design; distillation columns; HIDiC; heat integration; predictive control; dynamic systems; TEMPERATURE CONTROL;
D O I
10.1016/j.ifacol.2017.08.1506
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper benchmarks a centralized control system based on model predictive control for the operation of the heat integrated distillation column (HIDiC) against a fully decentralized control system using the most complete column model currently available in the literature. The centralized control system outperforms the decentralized system, because it handles the interactions in the HIDiC process better. The integral absolute error (IAE) is reduced by a factor of 2 and a factor of 4 for control of the top and bottoms compositions, respectively. (C) 2017, IFAC (International Federation of Automatic Control) Hosting by Elsevier Ltd. All rights reserved.
引用
收藏
页码:7375 / 7380
页数:6
相关论文
共 16 条
  • [1] Optimal operation and stabilising control of the concentric heat-integrated distillation column (HIDiC)
    Bisgaard, Thomas
    Skogestad, Sigurd
    Abildskov, Jens
    Huusom, Jakob K.
    [J]. COMPUTERS & CHEMICAL ENGINEERING, 2017, 96 : 196 - 211
  • [2] Modeling and analysis of conventional and heat-integrated distillation columns
    Bisgaard, Thomas
    Huusom, Jakob Kjobsted
    Abildskov, Jens
    [J]. AICHE JOURNAL, 2015, 61 (12) : 4251 - 4263
  • [3] Temperature control of an ideal heat-integrated distillation column (HIDiC)
    Huang, Kejin
    Wang, San-Jang
    Iwakabe, Koichi
    Shan, Lan
    Zhu, Qunxiong
    [J]. CHEMICAL ENGINEERING SCIENCE, 2007, 62 (22) : 6486 - 6491
  • [4] High-purity control of internal thermally coupled distillation columns based on nonlinear wave model
    Liu, Xinggao
    Zhou, Yexiang
    Cong, Lin
    Ding, Feng
    [J]. JOURNAL OF PROCESS CONTROL, 2011, 21 (06) : 920 - 926
  • [5] Luyben W.L., 2012, Practical Distillation Control
  • [6] FEEDBACK CONTROL OF DISTILLATION COLUMNS BY DOUBLE DIFFERENTIAL TEMPERATURE CONTROL
    LUYBEN, WL
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY FUNDAMENTALS, 1969, 8 (04): : 739 - &
  • [7] DISTILLATION WITH SECONDARY REFLUX AND VAPORIZATION - COMPARATIVE EVALUATION
    MAH, RSH
    NICHOLAS, JJ
    WODNIK, RB
    [J]. AICHE JOURNAL, 1977, 23 (05) : 651 - 658
  • [8] Minasidis V, 2015, COMPUT-AIDED CHEM EN, V37, P101
  • [9] Evaluating control structures for a general heat integrated distillation column (general HIDiC)
    Nakaiwa, M
    Huang, K
    Endo, A
    Naito, K
    Owa, M
    Akiya, T
    Nakane, T
    Takamatsu, T
    [J]. COMPUTERS & CHEMICAL ENGINEERING, 1999, 23 : S851 - S854
  • [10] Operating an ideal heat integrated distillation column with different control algorithms
    Nakaiwa, M
    Huang, K
    Owa, M
    Akiya, T
    Nakane, T
    Takamatsu, T
    [J]. COMPUTERS & CHEMICAL ENGINEERING, 1998, 22 : S389 - S393