Comparison of storage stability of odorous VOCs in polyester aluminum and polyvinyl fluoride Tedlar® bags

被引:63
作者
Kim, Yong-Hyun [1 ]
Kim, Ki-Hyun [1 ]
Jo, Sang-Hee [1 ]
Jeon, Eui-Chan [1 ]
Sohn, Jong Ryeul [2 ]
Parker, David B. [3 ]
机构
[1] Sejong Univ, Dept Environm & Energy, Seoul 143747, South Korea
[2] Korea Univ, Dept Environm Hlth, Seoul 136703, South Korea
[3] ARS, USDA, US Meat Anim Res Ctr, Clay Ctr, NE 68933 USA
基金
新加坡国家研究基金会;
关键词
Tedlar bag (PVF); Polyester bag (PEA); Relative recovery; Storage time; Sorptive loss;
D O I
10.1016/j.aca.2011.11.014
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Whole air sampling using containers such as flexible bags or rigid canisters is commonly used to collect samples of volatile organic compounds (VOC) in air. The objective of this study was to compare the stability of polyester aluminum (PEA) and polyvinyl fluoride (PVF, brand name Tedlar (R)) bags for gaseous VOC sampling. Eight VOC standards (benzene, toluene, p-xylene, styrene, methyl ethyl ketone, methyl isobutyl ketone, butyl acetate, and isobutyl alcohol) were placed into each bag at storage times of 0, 2, and 3 days prior to analyses by gas chromatography/mass spectrometry (GC/MS). From each bag representing each storage day, samples of 3 different mass loadings were withdrawn and analyzed to derive response factors (RF) of each chemical between the slope of the GC response (y-axis) vs. loaded mass (x-axis). The relative recoveries (RR) of VOC, if derived by dividing RF value of a given storage day by that of 0 day, varied by time, bag type, and VOC type. If the RR values after three days are compared, those of methyl isobutyl ketone were the highest with 96 (PVF) and 99% (PEA): however, the results of isobutyl alcohol were highly contrasting between the two bags with 31 and 94%, respectively. Differences in RR values between the two bag types increased with storage time, such that RR of PEA bags (88 +/- 10%) were superior to those of PVF bags (73 +/- 22%) after three days, demonstrating that VOC in PEA bags were more stable than in PVF bags. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:162 / 167
页数:6
相关论文
共 17 条
[1]   A STUDY OF THE STABILITY OF METHANOL-FUELED VEHICLE EMISSIONS IN TEDLAR BAGS [J].
ANDINO, JM ;
BUTLER, JW .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1991, 25 (09) :1644-1646
[2]  
[Anonymous], 2008, ANN REP AMB AIR QUAL
[3]  
Gosh S., 2011, SCI WORLD, V11, P2160
[4]   Development and application of a thermal desorption method for the analysis of polar volatile organic compounds in workplace air [J].
Hallama, RA ;
Rosenberg, E ;
Grasserbauer, M .
JOURNAL OF CHROMATOGRAPHY A, 1998, 809 (1-2) :47-63
[5]  
Hsieh C.-C., 2003, AEROSOL AIR QUAL RES, V3, P17, DOI DOI 10.4209/AAQR.2003.06.0003
[6]  
Jeon S.J., 1999, KOREAN SOC ATMOSPHER, V15, P417
[7]   A Preliminary Study on Polyester Aluminum Bag as the Possible Substitute for Tedlar Bag Sampler in RSC Analysis [J].
Kim, Ki-Hyun ;
Jo, Sang Hee .
JOURNAL OF KOREAN SOCIETY FOR ATMOSPHERIC ENVIRONMENT, 2011, 27 (04) :454-459
[8]  
Koziel JA, 2009, AIP CONF PROC, V1137, P55, DOI 10.1063/1.3156616
[9]  
Park S. -Y., 2008, KOREAN SOC ATMOSPHER, V11, P12
[10]  
Posner J.C., 1986, APPL IND HYG, V1, P163