A cross-differential protection scheme for quadruple-circuit lines with asymmetric parameters

被引:1
|
作者
Liu, Qi [1 ]
Tai, Nengling [1 ]
Fan, Chunju [1 ]
Yu, Zhongan [2 ]
Shang, Jin [1 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Elect Informat & Elect Engn, 800 Dongchuan Rd, Shanghai 200240, Peoples R China
[2] Jiangxi Univ Sci & Technol, Dept Mech & Elect Engn, Ganzhou, Jiangxi, Peoples R China
基金
中国国家自然科学基金;
关键词
quadruple-circuit lines; asymmetric parameters; cross-differential protection; sequence component; superimposed network; TRANSMISSION-LINE; ALGORITHM;
D O I
10.1002/etep.2166
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Quadruple-circuit lines with asymmetric parameters have been widely built to increase power transmission capacity. The asymmetric parameters of the lines lead to different current characteristics compared with traditional lines. A cross-differential protection scheme based on negative sequence fault current is proposed to overcome the deficiency of traditional protection scheme. The fault superimposed networks of quadruple-circuit lines are discussed to analyze the fault sequence currents of each line. Differential currents are deduced to form the relay criterion. The threshold values of protection are calculated according to characteristics of superimposed fault sequence currents. Corresponding operational logic is also introduced to ensure the stability and reliability of protection. Finally, the reliability of the proposed protection scheme is verified. Copyright (C) 2015 John Wiley & Sons, Ltd.
引用
收藏
页码:1646 / 1660
页数:15
相关论文
共 50 条
  • [1] Transverse differential protection for quadruple-circuit lines with asymmetrical parameters
    Liu, Qi
    Tai, Nengling
    Fan, Chunju
    Yu, Zhongan
    Shang, Jin
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2016, 31 (22): : 159 - 167
  • [2] A New Cross-Differential Protection Scheme for Parallel Transmission Lines Including UPFC
    Samantaray, Subhransur
    Tripathy, Lokanath
    Dash, Pradipta
    2016 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING (PESGM), 2016,
  • [3] A New Cross-Differential Protection Scheme for Parallel Transmission Lines Including UPFC
    Tripathy, L. N.
    Dash, P. K.
    Samantaray, S. R.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2014, 29 (04) : 1822 - 1830
  • [4] A New Approach to Measure the Distributed Parameters of Quadruple-Circuit Transmission Lines
    Hu Z.
    Ni S.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2018, 33 (03): : 563 - 572
  • [5] Analysis of ground distance protection for quadruple-circuit transmission lines on the same tower
    Zhang, Ying
    Tai, Neng-Ling
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2010, 38 (12): : 1 - 6
  • [6] Lightning protection performance of quadruple-circuit 500 kV transmission lines on the same tower with composite cross arm
    Li, Haichen
    Xiang, Nianwen
    Bao, Hua
    Jin, Miao
    Ding, Lijian
    ENERGY REPORTS, 2022, 8 : 520 - 526
  • [7] Lightning protection performance of 500 kV quadruple-circuit transmission lines on the same tower
    School of Electrical Engineering, Wuhan University, Wuhan 430072, China
    Gaodianya Jishu, 2008, 1 (168-171):
  • [8] The study of ground distance protection of 500kV quadruple-circuit transmission lines On the same tower
    Sun, Shujie
    Tai, Nengling
    Bo, Zhinqian
    2008 PROCEEDINGS OF THE 43RD INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, VOLS 1-3, 2008, : 436 - +
  • [9] Shielding failure lightning protection of 500kV quadruple-circuit transmission lines on the same tower
    Yu, Shifeng
    Ruan, Jiangjun
    2007 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-10, 2007, : 1705 - 1708
  • [10] Cross-voltage short-circuit calculation for mixed-voltage quadruple-circuit lines on the same tower
    Zheng, Tao
    Zhang, Jiaqin
    Wu, Dan
    Huang, Shaofeng
    Wang, Xiaoli
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2017, 11 (09) : 2342 - 2350