Characteristics of different mesh types for abdominal wall repair in an experimental model of peritonitis

被引:9
作者
Kaufmann, R. [1 ]
Jairam, A. P. [1 ]
Mulder, I. M. [1 ,4 ]
Wu, Z. [1 ,5 ]
Verhelst, J. [1 ]
Vennix, S. [1 ,4 ]
Giesen, L. J. X. [1 ]
Groningen, M. C. Clahsen-van [2 ]
Jeekel, J. [3 ]
Lange, J. F. [1 ]
机构
[1] Erasmus MC, Dept Surg, Room Ee-173,Wytemaweg 80, NL-3015 CN Rotterdam, Netherlands
[2] Erasmus MC, Dept Pathol, Rotterdam, Netherlands
[3] Erasmus MC, Dept Neurosci, Rotterdam, Netherlands
[4] Acad Med Ctr, Dept Surg, Amsterdam, Netherlands
[5] Peking Univ, Canc Hosp & Inst, Minist Educ, Gastrointestinal Canc Ctr,Key Lab Carcinogenesis, Beijing, Peoples R China
关键词
VENTRAL HERNIA REPAIR; INCISIONAL HERNIA; CONTAMINATED ENVIRONMENT; ADHESION FORMATION; BIOLOGICAL MESH; RAT MODEL; FOLLOW-UP; INFECTION; RECONSTRUCTION; BIOMATERIALS;
D O I
10.1002/bjs.10635
中图分类号
R61 [外科手术学];
学科分类号
摘要
BackgroundThe use of synthetic mesh to repair a potentially contaminated incisional hernia may lead to higher failure rates. A biological mesh might be considered, but little is known about long-term results. Both biological and synthetic meshes were investigated in an experimental model of peritonitis to assess their characteristics in vivo. MethodsMale Wistar rats were randomized into five groups and peritonitis was induced. A mesh was implanted after 24h. Five meshes were investigated: Permacol (cross-linked collagen), Strattice (non-cross-linked collagen), XCM Biologic((R)) (non-cross-linked collagen), Omyra((R)) Mesh (condensed polytetrafluoroethylene) and Parietene (polypropylene). The rats were killed after either 30, 90 or 180days. Incorporation and shrinkage of the mesh, adhesion coverage, strength of adhesions and histology were analysed. ResultsOf 135 rats randomized, 18 died from peritonitis. Some 180days after implantation, both XCM Biologic((R)) and Permacol had significantly better incorporation than Strattice (P=0003 and P=0009 respectively). Strattice had significantly fewer adhesions than XCM Biologic((R)) (P=0001) and Permacol (P=0020). Thirty days after implantation, Permacol had significantly stronger adhesions than Strattice (P<0001). Shrinkage was most prominent in XCM Biologic((R)), but no significant difference was found compared with the other meshes. Histological analysis revealed marked differences in foreign body response among all meshes. ConclusionThis experimental study suggested that XCM Biologic((R)) was superior in terms of incorporation, macroscopic mesh infection, and histological parameters such as collagen deposition and neovascularization. There must be sufficient overlap of mesh during placement, as XCM Biologic((R)) showed a high rate of shrinkage. Surgical relevance The use of synthetic mesh to repair a potentially contaminated incisional hernia is not supported unequivocally, and may lead to a higher failure rate. A biological mesh might be considered as an alternative. There are few long-term studies, as these meshes are expensive and rarely used. This study evaluated the use of biological mesh in a contaminated environment, and investigated whether there is an ideal mesh. A new non-cross-linked biological mesh (XCM Biologic((R))) was evaluated in this experiment. The new non-cross-linked biological mesh XCM Biologic((R)) performed best and may be useful in patients with a potentially contaminated incisional hernia. Variable characteristics
引用
收藏
页码:1884 / 1893
页数:10
相关论文
共 30 条
[1]   Long-term outcomes (&gt;5-year follow-up) with porcine acellular dermal matrix (Permacol™) in incisional hernias at risk for infection [J].
Abdelfatah, M. M. ;
Rostambeigi, N. ;
Podgaetz, E. ;
Sarr, M. G. .
HERNIA, 2015, 19 (01) :135-140
[2]   Incisional ventral hernias: Review of the literature and recommendations regarding the grading and technique of repair [J].
Breuing, Karl ;
Butler, Charles E. ;
Ferzoco, Stephen ;
Franz, Michael ;
Hultman, Charles S. ;
Kilbridge, Joshua F. ;
Rosen, Michael ;
Silverman, Ronald P. ;
Vargo, Daniel .
SURGERY, 2010, 148 (03) :544-558
[3]   The in vivo evaluation of tissue-based biomaterials in a rat full-thickness abdominal wall defect model [J].
Bryan, Nicholas ;
Ahswin, Helen ;
Smart, Neil ;
Bayon, Yves ;
Wohlert, Stephen ;
Hunt, John A. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2014, 102 (04) :709-720
[4]  
Burger JWA, 2004, ANN SURG, V240, P578
[5]   Ventral Hernia Repair with Synthetic, Composite, and Biologic Mesh: Characteristics, Indications, and Infection Profile [J].
Cevasco, Marisa ;
Itani, Kamal M. F. .
SURGICAL INFECTIONS, 2012, 13 (04) :209-215
[6]   A retrospective study evaluating the use of Permacol™ surgical implant in incisional and ventral hernia repair [J].
Chand, Bipan ;
Indeck, Matthew ;
Needleman, Bradley ;
Finnegan, Matthew ;
Van Sickle, Kent R. ;
Ystgaard, Brynjulf ;
Gossetti, Francesco ;
Pullan, Rupert D. ;
Giordano, Pasquale ;
McKinley, Aileen .
INTERNATIONAL JOURNAL OF SURGERY, 2014, 12 (04) :296-303
[7]  
Cheng AW, 2014, AM SURGEON, V80, P999
[8]   Laparoscopic repair of incisional hernias [J].
Cobb, WS ;
Kercher, KW ;
Heniford, BT .
SURGICAL CLINICS OF NORTH AMERICA, 2005, 85 (01) :91-+
[9]  
Cornwell Kevin G, 2009, Clin Podiatr Med Surg, V26, P507, DOI 10.1016/j.cpm.2009.08.001
[10]   Ventralight ST and SorbaFix Versus Physiomesh and Securestrap in a Porcine Model [J].
Deeken, Corey R. ;
Matthews, Brent D. .
JSLS-JOURNAL OF THE SOCIETY OF LAPAROENDOSCOPIC SURGEONS, 2013, 17 (04) :549-559