Evaluation of Dose Distribution in Intensity Modulated Radiosurgery for Lung Cancer under Condition of Respiratory Motion

被引:2
作者
Yoon, Mee Sun [1 ]
Jeong, Jae-Uk [1 ]
Nam, Taek-Keun [1 ]
Ahn, Sung-Ja [1 ]
Chung, Woong-Ki [1 ]
Song, Ju-Young [1 ]
机构
[1] Chonnam Natl Univ, Dept Radiat Oncol, Sch Med, Gwangju, South Korea
来源
PLOS ONE | 2016年 / 11卷 / 09期
关键词
STEREOTACTIC ABLATIVE RADIOTHERAPY; ARC THERAPY; ACCURACY;
D O I
10.1371/journal.pone.0163112
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The dose of a real tumor target volume and surrounding organs at risk (OARs) under the effect of respiratory motion was calculated for a lung tumor plan, based on the target volume covering the whole tumor motion range for intensity modulated radiosurgery (IMRS). Two types of IMRS plans based on simulated respiratory motion were designed using humanoid and dynamic phantoms. Delivery quality assurance (DQA) was performed using Arc-CHECK and MapCHECK2 for several moving conditions of the tumor and the real dose inside the humanoid phantom was evaluated using the 3DVH program. This evaluated dose in the tumor target and OAR using the 3DVH program was higher than the calculated dose in the plan, and a greater difference was seen for the RapidArc treatment than for the standard intensity modulated radiation therapy (IMRT) with fixed gantry angle beams. The results of this study show that for IMRS plans based on target volume, including the whole tumor motion range, tighter constraints of the OAR should be considered in the optimization process. The method devised in this study can be applied effectively to analyze the dose distribution in the real volume of tumor target and OARs in IMRT plans targeting the whole tumor motion range.
引用
收藏
页数:14
相关论文
共 23 条
  • [1] 3D DVH-based metric analysis versus per-beam planar analysis in IMRT pretreatment verification
    Carrasco, Pablo
    Jornet, Nuria
    Latorre, Artur
    Eudaldo, Teresa
    Ruiz, Agusti
    Ribas, Montserrat
    [J]. MEDICAL PHYSICS, 2012, 39 (08) : 5040 - 5049
  • [2] Sensitivity of volumetric modulated arc therapy patient specific QA results to multileaf collimator errors and correlation to dose volume histogram based metrics
    Coleman, Linda
    Skourou, Christina
    [J]. MEDICAL PHYSICS, 2013, 40 (11)
  • [3] Reconstruction of high-resolution 3D dose from matrix measurements: error detection capability of the COMPASS correction kernel method
    Godart, J.
    Korevaar, E. W.
    Visser, R.
    Wauben, D. J. L.
    van't Veld, A. A.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (15) : 5029 - 5043
  • [4] The role of stereotactic ablative radiotherapy (SBRT) in the management of oligometastatic non small cell lung cancer
    Guerrero, Eduardo
    Ahmed, Merina
    [J]. LUNG CANCER, 2016, 92 : 22 - 28
  • [5] Hauri P1, 2014, J APPL CLIN MED PHYS, V15, P4647, DOI DOI 10.1120/JACMP.V15I2.4647
  • [6] Dosimetric comparison of flattened and unflattened beams for stereotactic ablative radiotherapy of stage I non-small cell lung cancer
    Hrbacek, Jan
    Lang, Stephanie
    Graydon, Shaun N.
    Kloeck, Stephan
    Riesterer, Oliver
    [J]. MEDICAL PHYSICS, 2014, 41 (03)
  • [7] Initial experience of ArcCHECK and 3DVH software for Rapid Arc treatment plan verification
    Infusino, Erminia
    Mameli, Alessandra
    Conti, Roberto
    Gaudino, Diego
    Stimato, Gerardina
    Bellesi, Luca
    D'Angelillo, Rolando Maria
    Ramella, Sara
    Benassi, Marcello
    Trodella, Lucio
    [J]. MEDICAL DOSIMETRY, 2014, 39 (03) : 276 - 281
  • [8] Evaluation of patient DVH-based QA metrics for prostate VMAT: correlation between accuracy of estimated 3D patient dose and magnitude of MLC misalignment
    Kadoya, Noriyuki
    Saito, Masahide
    Ogasawara, Makoto
    Fujita, Yukio
    Ito, Kengo
    Sato, Kiyokazu
    Kishi, Kazuma
    Dobashi, Suguru
    Takeda, Ken
    Jingu, Keiichi
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (03): : 179 - 189
  • [9] Evaluation of tumor motion effects on dose distribution for hypofractionated intensity-modulated radiotherapy of non-small-cell lung cancer
    Kang, Hyejoo
    Yorke, Ellen D.
    Yang, Jie
    Chui, Chen-Shou
    Rosenzweig, Kenneth E.
    Amols, Howard I.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2010, 11 (03): : 78 - 89
  • [10] Lung stereotactic ablative radiotherapy (SABR): dosimetric considerations for chest wall toxicity
    Murray, Louise
    Karakaya, Ebru
    Hinsley, Samantha
    Naisbitt, Mitchell
    Lilley, John
    Snee, Michael
    Clarke, Katy
    Musunuru, Hima B.
    Ramasamy, Satiavani
    Turner, Rob
    Franks, Kevin
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1058)