Predictive value of specimen radiography for core needle biopsy of noncalcified breast masses

被引:19
作者
Berg, WA
Jaeger, B
Campassi, C
Kumar, D
机构
[1] Univ Maryland, Sch Med, Dept Radiol, Baltimore, MD 21201 USA
[2] Univ Maryland, Sch Med, Greenebaum Canc Ctr, Baltimore, MD 21201 USA
[3] Univ Maryland, Sch Med, Dept Pathol, Baltimore, MD 21201 USA
关键词
D O I
10.2214/ajr.171.6.9843311
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. Our objective was to determine the predictive value of specimen radiography for large core (14-gauge) needle biopsy of noncalcified breast masses. SUBJECTS AND METHODS. Eighty-four biopsies of 83 breast masses yielded 403 specimens. Specimens showing dense material on specimen radiography were predicted to be diagnostic; specimens showing intermediate- or low-density material were predicted to be nondiagnostic. Specimen radiographic and histopathologic findings were correlated for each specimen using vital dyes to mark individual specimens. RESULTS. Of the 403 specimens, 307 (76%) contained diagnostic material representative of the lesion, with a specific diagnosis achieved for 82 (99%) of 83 lesions (62 benign, 20 malignant). Of the 293 passes containing dense material, 268 (91%) proved to be diagnostic; 11 (18%) of 62 specimens containing only low-density material proved to be diagnostic. Of the 25 (9%) of 293 specimens containing radiographically dense but nondiagnostic material, 18 (72%) showed focal fibrosis and had missed the lesion; 15 (83%) of 18 such specimens were obtained in dense parenchyma. The positive predictive value of specimen radiography was 13 (100%) of 13 in fatty breasts; 77 (96%) of 80 in breasts with minimal scattered fibroglandular elements; 91 (94%) of 97 in heterogeneously dense breasts; and 35 (70%) of 50 in breasts with extremely dense parenchyma. Of the 16 lesions sampled stereotactically, specimen radiography helped assess the inadequacy of initial sampling in three (19%). In six (9%) of 68 sonographically guided biopsies, only one or two specimens could be obtained; specimen radiography helped us predict whether material was adequate for diagnosis. CONCLUSION. Radiography of core specimens obtained from noncalcified breast masses accurately reveals the adequacy of sampling unless the breast parenchyma is extremely dense. Such immediate assessment can help ensure adequate material from lesions that are difficult to biopsy and can thereby improve the diagnostic yield of large core needle breast biopsy.
引用
收藏
页码:1671 / 1678
页数:8
相关论文
共 29 条
  • [1] Lessons from mammographic-histopathologic correlation of large-core needle breast biopsy
    Berg, WA
    Hruban, RH
    Kumar, D
    Singh, HR
    Brem, RF
    Gatewood, OMB
    [J]. RADIOGRAPHICS, 1996, 16 (05) : 1111 - 1130
  • [2] Evaluation of 14- and 11-gauge directional, vacuum-assisted biopsy probes and 14-gauge biopsy guns in a breast parenchymal model
    Berg, WA
    Krebs, TL
    Campassi, C
    Magder, LS
    Sun, CCJ
    [J]. RADIOLOGY, 1997, 205 (01) : 203 - 208
  • [3] Percutaneous core biopsy of the breast: Effect of operator experience and number of samples on diagnostic accuracy
    Brenner, RJ
    Fajardo, L
    Fisher, PR
    Dershaw, DD
    Evans, WP
    Bassett, L
    Feig, S
    Mendelson, E
    Jackson, V
    Margolin, FR
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (02) : 341 - 346
  • [4] Burbank F, 1996, AM SURGEON, V62, P738
  • [5] Stereotactic breast biopsy of atypical ductal hyperplasia and ductal carcinoma in situ lesions: Improved accuracy with directional, vacuum-assisted biopsy
    Burbank, F
    [J]. RADIOLOGY, 1997, 202 (03) : 843 - 847
  • [6] Burbank F, 1996, AM SURGEON, V62, P128
  • [7] NONPALPABLE LESIONS DETECTED WITH MAMMOGRAPHY - REVIEW OF 512 CONSECUTIVE CASES
    CIATTO, S
    CATALIOTTI, L
    DISTANTE, V
    [J]. RADIOLOGY, 1987, 165 (01) : 99 - 102
  • [8] Nondiagnostic stereotaxic core breast biopsy: Results of rebiopsy
    Dershaw, DD
    Morris, EA
    Liberman, L
    Abramson, AF
    [J]. RADIOLOGY, 1996, 198 (02) : 323 - 325
  • [9] MAMMOGRAPHIC FEATURE ANALYSIS
    DORSI, CJ
    KOPANS, DB
    [J]. SEMINARS IN ROENTGENOLOGY, 1993, 28 (03) : 204 - 230
  • [10] NONPALPABLE BREAST-LESIONS - CORRELATION OF STEREOTAXIC LARGE-CORE NEEDLE-BIOPSY AND SURGICAL BIOPSY RESULTS
    ELVECROG, EL
    LECHNER, MC
    NELSON, MT
    [J]. RADIOLOGY, 1993, 188 (02) : 453 - 455