Pre- versus post-column oxidation liquid chromatography fluorescence detection of paralytic shellfish toxins

被引:25
作者
DeGrasse, Stacey L. [1 ]
van de Riet, Jeffrey [2 ]
Hatfield, Robert [3 ]
Turner, Andrew [3 ]
机构
[1] US FDA, Ctr Food Safety & Appl Nutr, Off Regulatory Sci, Div Analyt Chem,Spect & Mass Spectrometry Branch, College Pk, MD 20740 USA
[2] Canadian Food Inspect Agcy, Dartmouth Lab, Dartmouth, NS B3B 1Y9, Canada
[3] Ctr Environm Fisheries & Aquaculture Sci, Weymouth DT4 8UB, Dorset, England
关键词
LC; Oxidation; Paralytic shellfish toxins; Saxitoxin; Validation; POISONING TOXINS; PRECHROMATOGRAPHIC OXIDATION; QUANTITATIVE-DETERMINATION; ALEXANDRIUM; GULF; MUSSELS; OYSTERS; CLAMS; PSP;
D O I
10.1016/j.toxicon.2010.12.017
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Both pre- and post-column oxidation liquid chromatography methods with fluorescence detection are available for detecting paralytic shellfish toxins. Each method has been evaluated in multiple laboratories and validated as a potential alternative to the mouse bioassay. This communication compares the advantages and limitations of both methods. For a given laboratory, the selection of either method may be based primarily on practicality and less on any deficiencies in scientific merit. Published by Elsevier Ltd.
引用
收藏
页码:619 / 624
页数:6
相关论文
共 50 条
[21]   Determination of α-tocopherolquinone in human serum samples by liquid chromatography with fluorescence detection and on-line post-column derivatization [J].
Pollok, D ;
Melchert, HU .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1056 (1-2) :257-262
[22]   Determination of the paralytic shellfish poisoning toxins (PSP) in bivalve molluscs by HPLC with fluorescence detection [J].
LeaoMartins, JM ;
ComesanaLosada, M ;
GagoMartinez, A ;
RodriguezVazquez, JA .
QUIMICA ANALITICA, 1997, 16 (02) :93-99
[23]   Inter laboratory Comparison of Two AOAC Liquid Chromatographic Fluorescence Detection Methods for Paralytic Shellfish Toxin Analysis through Characterization of an Oyster Reference Material [J].
Turner, Andrew D. ;
Lewis, Adam M. ;
Rourke, Wade A. ;
Higman, Wendy A. .
JOURNAL OF AOAC INTERNATIONAL, 2014, 97 (02) :380-390
[24]   Indirect Quantitation of Saxitoxin by HPLC with Post-column Oxidation and Fluorometric Detection [J].
Watanabe, Ryuichi ;
Harada, Tomoko ;
Matsushima, Ryoji ;
Oikawa, Hiroshi ;
Oshima, Yasukatsu ;
Kaneniwa, Masaki ;
Suzuki, Toshiyuki .
ANALYTICAL SCIENCES, 2014, 30 (09) :931-936
[25]   Indirect Quantitation of Saxitoxin by HPLC with Post-column Oxidation and Fluorometric Detection [J].
Ryuichi Watanabe ;
Tomoko Harada ;
Ryoji Matsushima ;
Hiroshi Oikawa ;
Yasukatsu Oshima ;
Masaki Kaneniwa ;
Toshiyuki Suzuki .
Analytical Sciences, 2014, 30 :931-936
[26]   Determination of Gonyautoxin-4 in Echinoderms and Gastropod Matrices by Conversion to Neosaxitoxin Using 2-Mercaptoethanol and Post-Column Oxidation Liquid Chromatography with Fluorescence Detection [J].
Silva, Marisa ;
Rey, Veronica ;
Botana, Ana ;
Vasconcelos, Vitor ;
Botana, Luis .
TOXINS, 2016, 8 (01)
[27]   High-performance liquid chromatography determination of Zn-bacitracin in animal feed by post-column derivatization and fluorescence detection [J].
Capitan-Vallvey, LF ;
Titos, A ;
Checa, R ;
Navas, N .
JOURNAL OF CHROMATOGRAPHY A, 2002, 943 (02) :227-234
[28]   High-performance liquid chromatography with electrochemical detection of aspartame with a post-column photochemical reactor [J].
Galletti, GC ;
Bocchini, P .
JOURNAL OF CHROMATOGRAPHY A, 1996, 729 (1-2) :393-398
[29]   Development of a sensitive and selective liquid chromatography-mass spectrometry method for high throughput analysis of paralytic shellfish toxins using graphitised carbon solid phase extraction [J].
Boundy, Michael J. ;
Selwood, Andrew I. ;
Harwood, D. Tim ;
McNabb, Paul S. ;
Turner, Andrew D. .
JOURNAL OF CHROMATOGRAPHY A, 2015, 1387 :1-12
[30]   Analysis of paralytic shellfish toxins using high-field asymmetric waveform ion mobility spectrometry with liquid chromatography-mass spectrometry [J].
Beach, Daniel G. ;
Melanson, Jeremy E. ;
Purves, Randy W. .